• 제목/요약/키워드: Dental Laboratory Technology

검색결과 691건 처리시간 0.025초

임플란트 환자의 보철물에 대한 인식 및 관리 실태에 관한 연구 (A Study on subjective awareness and management status of Dental Implant Patients)

  • 이혜은;임중재
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.305-317
    • /
    • 2019
  • Purpose: The purpose of this study is to provide basic data for the improvement of dental care service for patient care. Methods: The survey period was from December 10, 2018 to June 10, 2019. The subjects were 180 patients who were treated with dental implant in 20 dental hospitals and clinics in Daejeon and Gyeonggi province. A total of 145 questionnaires were analyzed except for 35 copies which were unreliable or difficult to analyze. Results: The most important care method for prolonging the life time of dental implant prosthesis was the highest rate of correct brushing (39.4%), and a majority in the subjects used oral hygiene products (91.0%). With regard to discomfort after dental implant prosthesis, food particles between the teeth showed the highest response (49.7%), and discomfort with gum infections and bleeding and reduced mastication increased significantly with age (p<0.05), whereas feeling of irritation decreased significantly with age (p<0.05). Conclusion: This study is meaningful in that it approached the perception and discomfort of prosthesis from the patients' point of view. It needs to establish the basic data to improve dental treatment service for patient care.

Nanomechanical properties and wear resistance of dental restorative materials

  • Karimzadeh, A.;Ayatollahi, Majid R.;Nikkhooyifar, M.;Bushroa, A.R.
    • Structural Engineering and Mechanics
    • /
    • 제64권6권
    • /
    • pp.819-826
    • /
    • 2017
  • The effects of thermocycling procedure and material shade on the mechanical properties and wear resistance of resin-based dental restorative materials are investigated. The modulus of elasticity, hardness, plasticity index and wear resistance are determined for the conventional composite, the nanohybrid composite and the nanofilled dental composites. Disc-shape samples are prepared from each material to investigate the effects of thermocycling procedure on the mechanical properties and wear resistance of different types of dental restorative materials. In this respect, a group of samples is thermocycled and the other group is stored in ambient conditions. Then nano-indentation and nano-scratch tests are performed on the samples to measure their mechanical properties and wear resistance. Results show that the A1E shade of the dental nanocomposite possesses higher modulus of elasticity and hardness values compared to the two other shades. According to the experimental results, the mean values for the modulus of elasticity and hardness of the A1E shade of the nanocomposite are 13.71 GPa and 1.08 GPa, respectively. The modulus of elasticity and hardness of the conventional dental composite increase around 30 percent in the oral environment due to the moisture and temperature changes. The wear resistance of the dental composites is also significantly affected by moisture and temperature changes in the oral conditions. It is observed that thermocycling has no significant effect on the hardness, plasticity index and wear resistance of the nanohybrid composite and the nanocomposite dental materials.

건강보험 급여화 관련 치과임플란트보철물 제작실태 연구 (A Study on The Dental field of Present Health Insurance for custom-made Prosthetic implant by Dental technicians)

  • 이희경;조미향
    • 대한치과기공학회지
    • /
    • 제38권1호
    • /
    • pp.9-22
    • /
    • 2016
  • Purpose: The Purpose of this study are to describe the Dental field of present health insurance for custom-made prosthetic implant by dental technicians' work. Results: A total of 300 dental technicians working at dental laboratories in Korea were randomly selected and surveyed, 206(68.7%) of them were used for the statistical analysis. Conclusion: Average daily working time was 10 hours 66%. The average cumulative credit of the clinic for dental prosthesis fabrication rates was Less than 10 million won(21.8%), 10~80 million won(11.7%), more than one hundred million won(1.5%). Remake dental prosthesis was one more than the monthly average of 98.5%. Causes of remake dental prosthesis was dentist impression 83% but did not pay 62.5%. Dental technicians Implant production period was 7 days(48.5%), 10 days(35%) was commissioned by dentists production time is 5 days(46.1%), 7 days(36.5%). President of dental laboratories 3.86 points and dental technicians 3.06 points knew differently about starting of implant health insurance coverage(p<.001). They alike were in favor of insurance coverage for the implant. Dental technicians were lower by 2.36 points for work do you know whether your health insurance application of dental prostheses. Dental technicians are 2.16 points on whether confidence in the pores payment of insurance coverage dental prosthesis, dental laboratory president was lower by 1.85 points. They are very low with 1.97 points on whether confidence in the rate payment of health insurance coverage dental prosthesis(p<.01). The implant prosthesis abutment selected, the abutments designed, design of the implant upper prosthetic, the upper prosthetic fitting dental technicians participate of dental laboratory president showed higher score (p <.05). Conclusion: Hours of dental technicians were making this short period of remake dental prosthesis-related dental prosthesis. Dental clinic and a detailed representation of the dental prosthodontic fabrication request is required for communication between the laboratory in order to reduce the remake of a dental prosthesis, dental insurance coverage written dental prosthodontic fabrication request should be legislated. Implant classification standard medical practice 1-3 Step conduct a thorough costing a total of no. 73 of the correct classification standard medical practice in addition to eight times defined by the act of dental technicians should be defined.

치과용합금(齒科用合金)type에 따른 조성(組成) 및 경도(硬度)에 관(關)한 연구(硏究) (On Composition and HB of Dental Alloys)

  • 현중구;이병기
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.13-18
    • /
    • 1985
  • Casting alloys, both precious and non-precious, were by heat in order to observe the change in HB and the results were : 1. The hard treatment showed 1.4 - 1.5 times as high as the soft treatment in HB. 2. The experiment shows that Au-Pt should be contained more than 75% to prevent color change. 3. Cu by hard teatment played the greatect part in creasing the solidity of Ag-Cu alloy. 4. Casting Co-Cr alloys showed little difference of HB in heat treatment.

  • PDF

치과용 지르코니아 표면처리방법에 따른 지르코니아와 전장용 도재의 결합강도 관찰 (Shear Bond Strength of Zirconia and Ceramics according to Dental Zirconia Surface Treatment)

  • 이광영;최성민
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.279-285
    • /
    • 2019
  • Purpose: The dental CAD / CAM system has been popular with the development of the digital dental industry. Zirconia is a typical material in dental CAD / CAM systems. Zirconia crowns are classified into single layer and double layer. This study is about the double layer crown of zirconia. The surface roughness, bond strength and fracture patterns of the zirconia surface were observed. Methods: Zirconia blocks were cut using a low speed cutter. Sintered to form a plate shape (6mm × 6mm × 3mm). The prepared specimens were surface treated in four ways. Surface roughness and bond strength were measured. And the fracture pattern was observed. Results: Result of surface treatment of zirconia. The surface roughness test results were as ET 2.87 ㎛, ST 2.67 ㎛, LT 2.44 ㎛, AT 2.41 ㎛, CN 2.08 ㎛ order. Bond Strength results were as LT 25.09 MPa, AT 23.27 MPa, ST 21.27 MPa, ET 21.09 MPa, CN 16.12 MPa order. Fracture patterns showed cohesive failure of 25-50% of the bond area. Conclusion: Surface roughness, bond strength and fracture pattern of the zirconia surface were observed. Etching the surface treatment of zirconia materials has been shown to affect the surface roughness. Zirconia special binder treatment has been shown to affect the bond strength improvement.

백색광과 청색광 스캐너를 이용한 지대치 인상체 스캐닝의 반복재현성 비교 (Comparison of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners)

  • 전진훈;성환경;민병국;황재선;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.213-218
    • /
    • 2015
  • Purpose: The purpose of this study compared of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners. Methods: To evaluate reproducibility with white and blue light scanners, the impression of premolar were rotated by $10^{\circ}{\sim}20^{\circ}$ and scanned. These data were compared with the first 3-D data (STL file), and the error sizes were measured (n=5). Independent t test was used to evaluation the reproducibility of impression of premolar with white versus blue light scanners through discrepancies of mean, RMS (${\alpha}=0.05$). Results: Discrepancies of mean with regard to reproducibility were $11.2{\mu}m$, $5.8{\mu}m$, respectively, with white and blue light scanners (p<0.047). And discrepancies of RMS with regard to reproducibility were $33.4{\mu}m$, $18.8{\mu}m$, respectively, with white and blue light scanners (p<0.045). Conclusion: Our results indicate a good reproducibility of prepared tooth impression digitized with blue light scanner more than that with white light scanner.

치과용 바렐연마를 이용한 치과용 합금의 부피와 무게의 변화율 관찰 (Observation of the change rate of volume and weight of dental alloy using dental barrel finishing)

  • 고현정;박유진;최성민
    • 대한치과기공학회지
    • /
    • 제45권2호
    • /
    • pp.48-53
    • /
    • 2023
  • Purpose: This study aimed to provide the basic data for dental barrel finishing by observing the abrasiveness of the metal body according to the time of the barrel finishing. Methods: This study included three types of Co-Cr alloys. The specimens were manufactured by casting method using 10-mm diameter wax spheres (n=10). The cast alloys were polished for 60 minutes at intervals of 5 minutes in barrel finishing. The weight and volume of the specimens were measured, and the rate of change was calculated. The data obtained from the three groups (α=0.05) were compared and analyzed using one-way ANOVA. Results: As a result, the overall volume and weight of the group decreased after grinding compared with the control group. Conclusion: When grinding dental barrel finishing, no difference was observed in the processing rate depending on the type of alloy and the processing rate of the alloy body is within 30 minutes; hence, dental barrel finishing can be effectively used for grinding.

의료서비스가 치과의료기관 선택에 미치는 영향 조사 (The research about the influence of medical service when choosing the dental clinic.)

  • 이규선;민병국
    • 치위생과학회지
    • /
    • 제8권2호
    • /
    • pp.51-56
    • /
    • 2008
  • 이 연구의 목적은 치과의료 소비자가 원하는 서비스의 중요도를 정확히 파악한 후, 치과의료서비스의 개선을 위한 자료를 얻는데 있다. 본 연구는 2008년 3월 17일부터 3월 25일까지 수원시 소재 대학의 치기공과에 재학 중인 1,2,3학년 학생 261명을 대상으로 각각 3부씩의 설문지를 배부하고, 학생 본인을 포함하여 가족과 지인에게 설문하는 방법으로 조사하였으며, 배부된 783부의 설문지 중 584부를 회수하여 분석한 결과 다음과 같은 결론을 얻었다. 치과의료기관을 선택할 때 고려하는 의료서비스와 관련된 변수들의 피어슨 상관관계를 산출한 결과 모든 영역별로 정의 상관관계가 있는 것으로 나타났으며, 각 세부영역 중 병원의 물리적 환경과 치과의사의 외향적 자질과의 상관관계가 가장 높게 나타났으며, 그 다음으로 교통의 편의성과 병원의 기본요소, 병원의 물리적 환경과 병원의 기본요소, 치과의사의 외향적 자질과 병원의 기본요소, 교통편의성과 병원의 물리적 환경, 교통편의성과 치과의사의 외향적 자질 순으로 유의한 정의 상관관계를 나타냈다. 전체 변수들 간의 고려사항 역시 정의 상관관계가 있으며, 병원의 물리적 환경을 가장 중요하게 생각하고, 병원의 기본요소, 교통 편의성, 치과의사의 외향적 자질 순으로 중요하게 생각하는 것으로 나타났다.

  • PDF