• 제목/요약/키워드: Dental Implant System

검색결과 330건 처리시간 0.033초

Controlled release of nerve growth factor from heparin-conjugated fibrin gel within the nerve growth factor-delivering implant

  • Lee, Jin-Yong;Kim, Soung-Min;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권1호
    • /
    • pp.3-10
    • /
    • 2014
  • Objectives: Although nerve growth factor (NGF) could promote the functional regeneration of an injured peripheral nerve, it is very difficult for NGF to sustain the therapeutic dose in the defect due to its short half-life. In this study, we loaded the NGF-bound heparin-conjugated fibrin (HCF) gel in the NGF-delivering implants and analyzed the time-dependent release of NGF and its bioactivity to evaluate the clinical effectiveness. Materials and Methods: NGF solution was made of 1.0 mg of NGF and 1.0 mL of phosphate buffered saline (PBS). Experimental group A consisted of three implants, in which $0.25{\mu}L$ of NGF solution, $0.75{\mu}L$ of HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin was injected via apex hole with micropipette and gelated, were put into the centrifuge tube. Three implants of experimental group B were prepared with the mixture of $0.5{\mu}L$ of NGF solution, $0.5{\mu}L$ HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin. These six centrifuge tubes were filled with 1.0 mL of PBS and stirred in the water-filled beaker at 50 rpm. At 1, 3, 5, 7, 10, and 14 days, 1.0 mL of solution in each tubes was collected and preserved at $-20^{\circ}C$ with adding same amount of fresh PBS. Enzyme-linked immunosorbent assay (ELISA) was done to determine in vitro release profile of NGF and its bioactivity was evaluated with neural differentiation of pheochromocytoma (PC12) cells. Results: The average concentration of released NGF in the group A and B increased for the first 5 days and then gradually decreased. Almost all of NGF was released during 10 days. Released NGF from two groups could promote neural differentiation and neurite outgrowth of PC12 cells and these bioactivity was maintained over 14 days. Conclusion: Controlled release system using NGF-HCF gel via NGF-delivering implant could be an another vehicle of delivering NGF to promote the nerve regeneration of dental implant related nerve damage.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향 (Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws)

  • 신현모;조욱;정창모
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.53-59
    • /
    • 2009
  • 본 연구는 external butt joint 연결 형태를 가진 임플랜트 시스템에서 티타늄 합금 나사와 텅스텐 카바이드와 탄소로 코팅한 나사의 압축력 및 조임 회전각 측정을 통해 동일한 전하중을 얻는 데 있어 코팅나사 사용이 갖는 임상적 효율성을 간접적으로 비교해 보고자 하였다. 본 연구에서는 Osstem Implant의 US II 시스템 고정체(${\phi}=4mm$)와 Cemented abutment를 사용하여 티타늄 합금(Ta) 지대주 나사 및 텅스텐 카바이드와 탄소로 표면 처리한(WC/CTa) 지대주 나사에 30Ncm의 조임 회전력을 적용한 후 압축력 및 조임 회전각을 측정하였다. 다음 WC/CTa 지대주 나사에서 측정된 압축력의 평균값을 계산하고 이를 Ta 지대주 나사에 적용하여 동일한 압축력이 가해질 때의 조임 회전력 값을 측정하였다. 그리고 실험결과 측정된 조임 회전력의 평균값을 Ta 나사에 적용한 후 조임 회전각을 측정하여 비교해 본 결과 다음과 같은 결론을 얻었다. 30Ncm의 조임 회전력에서 텅스텐 카바이드/탄소 코팅 나사가 티타늄 합금 나사보다 압축력과 회전각이 더 높게 나타났다. 텅스텐 카바이드/탄소 코팅 나사에 30Ncm의 조임 회전력을 적용하여 발생한 압축력을 얻기 위해서는 티타늄 합금 나사의 경우 55.6Ncm의 조임 회전력이 필요하였으며, 회전각에는 두 나사 간에 차이가 없었다.

마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향 (Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery)

  • 마이해엔;이두형
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.219-224
    • /
    • 2019
  • 목적:컴퓨터 가이드 임플란트 수술에서 방사선 영상과 디지털 영상과의 정합은 필수적인 과정이다. 본 연구의 목적은 마이크로스크류의 사용이 가이드 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향을 조사하는 것이다. 재료 및 방법: 연구모형의 제작을 위해 Kennedy class I 하악 덴티폼에 마이크로스크류 2개를 후구치 삼각 부위에 식립 후 컴퓨터 단층촬영과 디지털 스캔을 통해 방사선 영상과 스캔 영상을 획득하였다. 영상들은 잔존 치아 부위만을 이용하는 방법과 치아와 마이크로스크류를 이용하는 방법을 이용하여 12명의 술자에 의해 중첩되었다. 이 중첩된 영상에 대하여 작업시간, 술자편의성, 만족도의 자료가 수집되고, Mann-Whitney U test을 통해 분석되었다. 결과: 작업시간은 영상정합 조건 사이에 통계학적인 차이가 없었다 (P > .05). 술자편의성과 만족도는 치아와 마이크로스크류를 이용하는 방법에서 잔존 치아 부위만을 이용하는 방법보다 높았다 (P < .001). 결론: 영상정합에서 마이크로스크류의 이용은 작업시간의 단축에는 영향을 미치지 않지만 술자편의성과 만족도는 향상시킨다.

두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study) (Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study)

  • 이지은;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.169-174
    • /
    • 2008
  • 목적: 치과 임플랜트 주위의 변연골 변화는 임플랜트의 기능적인 유지 뿐만 아니라 심미적 성공을 위해서도 중요하다. 변연골의 유지를 위한 임플랜트 디자인이 연구되고 있다. 이번 예비 연구는 두 종류의 external hex implant 시스템에서 임플랜트의 상부 미세 나사산이 변연골 변화량에 미치는 영향을 평가하고자 한다. 재료 및 방법: 총 24명의 환자를 대상으로 $Br{{\aa}}nemark$ 임플랜트 식립군 (1군, 거친 표면 임플랜트, 20개)과 원플란트 임플랜트 식립군 (2군, 미세나사산을 가진 거친 표면 임플랜트, 20개)으로 분류하였다. 기준 시점 (임플랜트 부하)과 부하를 가한 1년 뒤 임상적, 방사선학적 검사를 시행하였다. UTHSCSA Image Tool을 이용하여 임플랜트-보철 경계부로부터 변연골 높이 변화량으로 계측하였다. 계측치는 SAS 프로그램을 이용하여 three-level ANCOVA로 통계처리 하였다. 결과: 기준 시점과 비교하여 1년 기능 후, 두 그룹 간의 변연골 소실 변화량에 있어서 통계학적으로 유의한 차이가 있었다 (P<0.05). 1군의 평균 변연골 높이 변화량은 $0.83{\pm}0.31mm$, 2군에 있어서는 $0.44{\pm}0.36mm$ 이었다. 미세나사산을 가진 거친 표면 임플랜트가 미세나 사산을 가지지 않은 거친 표면 임플랜트 보다 더 적은 변연골 소실 변화량을 보였다. 결론: 미세나사산을 가진 거친 표면 임플랜트가 기능적 부하 후 변연골 높이를 유지하는데 있어 더 유리한 디자인으로 보인다.

예비치과위생사의 취업에 관한 의식 조사 (A Survey on Preliminary Dental Hygienists' Senses of Employment)

  • 한수진;이선미;임미희
    • 한국치위생학회지
    • /
    • 제7권4호
    • /
    • pp.583-594
    • /
    • 2007
  • The purpose of this study was to conduct a survey on the senses that preliminary dental hygienists have on employment, who applied for the National Dental Hygienist Examination, so that it could provide a basic reference required for fostering good human resources specializing in oral health with a sense of mission and responsibility as professional. To meet these goals, a self-administered questionnaire survey was conducted for participants in a refresher education meeting for preliminary dental hygienists across three major regions(Seoul, Daejeon and Busan), which was held by the Korean Dental Hygienists Association(KDHA) on Jan. 15, 2006. Total 289 sheets of questionnaire were collected, and 262 sheets except invalid or incomplete ones were used for examination and analysis. As a result, this study came to the following conclusions: First, it was found that 40.4% respondents wanted to be employed in dental clinic or hospital. Most respondents(90.1%) answered that faithfulness is most valued as prerequisite qualification for employment in hospital, and highest percentage of respondents(39.3%) wanted to earn 16 to 17 million Korean won annually. For internship opportunities, 61.9% respondents replied that they could willingly accept the internship, provided that basic pay and switchover to regular employee are all assured. Second, as the results of survey on employment circumstances around respondents, it was found that most respondents(58.3%) were employed in dental clinic or hospital, and highest percentage of respondents(35.0%) earned 15 to 16 million Korean won. Third, it was found that interpersonal relationships among employees had most significant effects(4.81) on selection of employment, which was followed by in-house welfare benefits 1(monthly/annual vacation, resting room, etc; 4.56). For possible influential factors on the selection of employment depending on whether employed or not, it was found that there were Significant differences in pay, welfare benefit 2(seminar, orientation, refresher training opportunities, etc), post-wedding continued employment and merit system between employees and non-employees(pE0.05). Fourth, the survey on respondents' occupational senses of dental hygienist showed that major tasks of dental hygienists were represented by oral disease prevention(92.6%), case management(71.5%), oral health education(66.3%), hospital/clinic management and dental management support(10.4%) and public oral health activities(6.7%) respectively. For job satisfaction, it was found that almost half respondents(48.9%) showed satisfaction at their job and 32.6% felt satisfied at and proud of their job. That is, majority of respondents(81.5%) felt satisfied at their job as dental hygienist. For follow-up requirements to qualify for dental hygienists, it was found that 73.3% felt it necessary to give more investments to self-development, 62.2% respondents considered protection of membership's rights as one of future assignments that KDHA should be more committed to. For future social awareness about dental hygienists as occupation, 69.2% respondents expected that they would be better developed and treated as professional. And desired training courses as a part of qualification for professional dental hygienists were represented by case management(services, manners, etc; 33.3%), implant(28.9%), esthetics(correction, prosthesis, whitening; 18.9%) and so on. For an item on working years, it was noted that 75.9% respondents would keep working as dental hygienists as long as they could.

  • PDF

악안면 보철의 임상적 고찰;골내 매식술을 통한 보철적 회복에 관하여 (CLINICAL STUDY OF MAXILLOFACIAL PROSTHESES;OSSEOINTEGRATED IMPLANTS FOR MAXILLOFACIAL PROSTHESES)

  • 민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권5호
    • /
    • pp.406-414
    • /
    • 2001
  • 현재 악안면 보철 제작에 있어 재료로 실리콘이 제일 많이 사용되고 있으나 이 재료는 시간이 지남에 따라 점차 굳어져 가고 탄력성을 잃으며 원래의 색도 노랗게 변색되어 간다는 단점이 있다. 이러한 재료의 화학적 구성 단점 때문에 보철 생명력을 유지하기 위하여 환자들은 매 3년마다 새로운 보철물을 재 제작하여야 한다. 그렇다면 복잡했던 악안면 기공 과정을 다시 반복해야 하는 시간적, 물질적 손실을 감수해야 했다. 이러한 단점들을 보완하고 환자 피부색과 적합이 잘 되는 다양한 색의 실리콘 개발과 아울러 눈동자를 깜빡일 수 있는 인공 눈동자의 개발 등이 필요하며, 눈동자를 만드는데 사용되는 인공 수정체의 발전이 향후 악안면 보철 분야의 큰 과제라 할 수 있다.

  • PDF

치과 임플란트용 골융합 측정기의 설계 및 평가 (Design and Evaluation of Osseointegration Analysis System for Dental Implant)

  • 이주희;김창일;김철민;백종후;조정호;전명표;정영훈;이정배;이승대;이영진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.295-295
    • /
    • 2010
  • 생체 식립형 임플란트의 경우 성공도는 매식체의 골유착 정도에 크게 영향을 받는다. 골유착 시 임플란트의 표면 형상과 하중, 골질의 양 등 많은 요인에 영향을 받게 되므로, 임플란트의 안정성을 주기적으로 점검해야할 필요가 있다. 따라서 임플란트 안정성을 공진 주파수 분석법을 이용하여 측정하기 위해 압전소자 제작과 트랜스듀서의 구조를 설계하였다. 유한요소 해석을 통하여 압전소자와 트랜스듀서의 두께와 크기 변화를 통해 측정 주파수 범위를 10kHz대역으로 맞추었으며, 해석 결과를 토대로 샘플제작과 평가를 실시하였다. 평가 결과 시뮬레이션 해석결과와 유사한 10kHz의 주파수 대역을 가지는 것을 볼 수 있었고, 식립된 나사의 고정도가 증가할수록 주파수가 점차 증가하는 결과를 얻을 수 있었다.

  • PDF

치과 임플랜트용 고정체 인상법과 지대원주 인상법간의 정확성 비교 (A COMPARISON OF ACCURACY BETWEEN FIXTURE IMPRESSION AND ABUTMENT IMPRESSION FOR DENTAL IMPLANTS)

  • 최현식;임순호;조인호
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.662-673
    • /
    • 1997
  • The purpose of this study was to compare the accuracy between future impression and abutment impression using strain gauges. The master model used in this study was a partially edentulous mandibular metal cast with two fixture analogs on both sides. On the left, two future analogs were parallel, whereas right side, posterior future analog exhibiting a 15-degree lingual inclination. From master cast, 10 impressions were made for each of the three impression methods. The master frameworks was fabricated on the master model, and two-element strain gauge was attached to a master framework. The master framework was seated on each cast, and gold screws were tightened to 10 Ncm using a torque controller AI-1600 strain measurement system was used for strain measuring. Impression methods studied were : Group 1:abutment impression Group 2:fixture impression Group 3:combined impression (anterior:fixture impression, posterior:abutment impression) The results were as followed. 1. The strain values on X-axis and Y-axis according to the three impression methods showed no significant difference. 2. The strain values on parallel and angulated groups according to the three impression methods showed no significant difference. 3. The parallel group exhibited significantly higher accuracy in adaptation than angulated group for all experimental groups (p<0.05). In conclusion, it is considered that accuracy of implant prostheses is more affected by implant angulation than impression methods.

  • PDF

주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구 (THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS)

  • 오수연;방몽숙;양홍서;박상원;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

Original Article 1 - 즉시 혹은 조기하중 임프란트에 관한 후향적 연구 (Retrospective Clinical Study of Immediate or Early Loading of Implants)

  • 이승연;김영균;윤필영;이양진;여인성
    • 대한치과의사협회지
    • /
    • 제48권2호
    • /
    • pp.119-126
    • /
    • 2010
  • Introduction. In this study, we applied the immediate loading to implant using temporary prosthesis, and compared the treatment results by each placement site, amongst pre-loading period. The study was intended to search for occurrence of complications and the amount of marginal bone resorption. Materials and Methods. We retrospectively reviewed the medical records of 99 cases of implants from 29 patients who were treated at Seoul National University Bundang Hospital from September 2003 to September 2008. We grouped all the cases by placement arches and pre-loading periods, and subdivided each group by placement site(anterior/posterior), type of prosthesis(full-mouth cross splinting/Partial multiple splinting, Single). Results. In the cases of anterior maxilla, the average amounts of marginal bone resorption showed $1.71{\pm}0.71mm$ in group 1, and $1.44{\pm}0.69mm$ in group 2, which means they revealed no statistically significant difference between group 1 and group 2(p=0.646). In the cases of posterior maxilla, the average amounts of marginal bone resorption showed $1.25{\pm}0.72mm$ in group 1, and $1.14{\pm}1.15mm$ in group 2, which means they were not statistically significant. In the cases of anterior mandible, there was no cases classified as group 4, but the average amounts of marginal bone resorption in group 3 showed $1.38{\pm}0.79mm$. In the cases of posterior mandible, Group 3 showed $1.39{\pm}0.64mm$, and group 4 showed $1.84{\pm}1.19mm$ as amounts of marginal bone resorption, which means they revealed no statistically significant difference between group 3 and group 4(P=0.210). The survival rate of group1 was 97.14%, 92.1% of group3, and 100% of group 2 and group4. According to each type of prosthesis, each average amount of marginal bone resorption revealed no statistically significant difference in maxi11a(p=0.575) in mandible(p=0.206). Conclusion. It is concluded that the marginal bone resorption and the rate of complications might not be affected by placement sites and pre-loading periods. The marginal bone resorption and the rate of complications might vary as different bone quality of placement site and implant system, diameter, length, etc. It is suggested that the proper placement of immediate loading implants decreases the whole treatment period and any inconvenience occurred to patients.