• 제목/요약/키워드: Dental Implant System

검색결과 330건 처리시간 0.024초

티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석 (Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis)

  • 홍민호
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

노인의 치과임플란트 건강보험 급여 이용률 현황 (Utilization rate of dental implant for elderly in National Health Insurance in Korea)

  • 류재인;전지은
    • 대한치과의사협회지
    • /
    • 제57권9호
    • /
    • pp.496-503
    • /
    • 2019
  • A dental implant has been covered by National Health Insurance (NHI) in Korea since 2014. Every year the age group covered was extended and the out-of-pocket payment was decreased. This study analyzed the dental implant utilization rate by the National Health Insurance customized DB during the last 5 years. As a result, the utilization rate has been rapidly increasing steeply. The differences by age and sex in the utilization rate of dental implants were explored. The inclusion of a dental implant in the NHI system contributed to improving the dental accessibility of the elderly in Korea. However, a deep discussion is needed whether it is appropriately provided to necessary patients. The utilization rate will increase further in the future. Therefore, continuous monitoring and critical policy review should be continued.

  • PDF

Early implant failure: a retrospective analysis of contributing factors

  • Kang, Dae-Young;Kim, Myeongjin;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Caballe-Serrano, Jordi;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제49권5호
    • /
    • pp.287-298
    • /
    • 2019
  • Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.

지르코니아 및 티타늄 고정체 소재가 지대주 나사의 응력 분포에 미치는 영향: 3차원 유한 요소 분석 (Influence of zirconia and titanium fixture materials on stress distribution in abutment screws: a three-dimensional finite element analysis)

  • 김은영;홍민호
    • 대한치과기공학회지
    • /
    • 제43권2호
    • /
    • pp.42-47
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the stability of abutment screws used with the zirconia fixture-based implant system and compare them with those used with the existing titanium fixture system via the finite element method. Methods: A single implant-supported restoration was designed for the finite element analysis. A universal analysis program was used to set 8 occlusal points along the direction to the long axis of the implant, and an occlusal load of 700 N was applied. Results: In all models (Zir and Ti-fixture model), the screw threads presented with the highest von Mises stress (VMS) values, whereas the head and end presented with the lowest VMS values. The VMS of the screw used in the zirconia-fixture model was 5.97% lower than that used in the titanium-fixture model (261.258 vs. 276.911 MPa, respectively) despite statistical significance. Furthermore, the zirconia fixture (352.912 MPa) had a higher stress value (8.42%) than the titanium fixture (332.331 MPa). In a completely tightened titanium fixture implant system, the stress was concentrated in the implant-abutment connection interface, the zirconia fixture presented with a stable stress distribution. Conclusion: Although the zirconia fixture demonstrated a high VMS value, owing to the stiffness and elasticity coefficients of the material, the stress generated in the abutment screws was similar in all models. In conclusion, the zirconia fixture-based implant system presented with a more stable stress distribution in the abutment screws than the titanium fixture-based implant system.

치과용 임플란트 보철물적용환자의 만족요인 (A Study on Satisfaction Factors with Dental Implant Patients)

  • 이성욱;김지환
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.67-81
    • /
    • 2006
  • This research has been attempt to examine closely factors that high cost and value to overall satisfaction state for dental implant prosthesis, re-utilization intention, inducement intention of the general hospital dental service user and provide basis data necessary to establish competitive general hospital dentistry management strategy. Collected data using own recording way questionnaire from April 17, 2004 to May 15, 2004 choosing 142 people that agree on this research and question of 361 people that dental implant prosthetic treatment finished from March 1, 1999 to March 1, 2004 for this. Major analyzation consequences are as follows : First, general satisfaction, re-utilization intention, inducement intention for implant prosthesis that highly correlation variables are kindness, explanation, medical treatment level and appreciation of the aesthetic. Second, correlation is high relatively between re-utilization intention, inducement intention in the 3 variables such as general satisfaction re-utilization intention, inducement intention. Third, the result of multiple regression analysis showed that most significant effective factors are satisfaction with explanation of dental implant prosthesis between the 3 dependant variables such as general satisfaction, re-utilization intention, inducement intention. In looking into these consequence, how to improve that raise satisfaction about dental implant prosthetic treatment and to establish patient focused care service system for dental implant prosthesis, it is consider that explain enough about implant prosthesis and raise quality of medical examination and treatment level, including satisfied with fabrication of good esthetic dental implant prosthesis.

  • PDF

SLM법으로 매크로 육각다공질 구조를 부여한 치과 임플란트의 역학 분석 (Mechanical Analysis of Macro-Hexagon Porous Dental Implant Using Selective Laser Melting Technique)

  • 김부섭;최성민
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.55-61
    • /
    • 2011
  • Purpose: In this study, FEM(Finite Element Method) and bending strength test was conducted using normal implant and porous implant for the mechanical estimation of porous dental implant made by SLM method. Methods: Mechanical characteristics of PI(porous implant) and NI(normal implant) applied distributed loads(200N, 500N) were observed through FEM analysis. And each bending strength was gotten through bending test using MTS(Mechanical Test System, Instron 8871). Results: The result of FEM analysis was observed that stress difference between upper and surface of PI was 12 times, while NI was 2 times. The result of bending test was observed that bending strength of PI was lower than NI. we made a decision about this result that cross-sectional area of NI was larger than the PI. Conclusion: The stress shielding ability of porous implant was better than normal implant through result of FEM analysis. And bending strength of porous implant was lower than NI. We think that cause of this result was difference of cross-sectional area.

임상가를 위한 특집 3 - 임플란트의 새로운 응용 - 임플란트 매개 약물 전달 시스템 (New Application of Endosseous Implants - Implant Mediated Drug Delivery System(IMDDS))

  • 박영석;이신재;황치일
    • 대한치과의사협회지
    • /
    • 제52권9호
    • /
    • pp.550-557
    • /
    • 2014
  • The restorative treatment with dental implants in edentulous patients has been a well documented treatment modality proven in experimental studies and long-term clinical investigations. The aim of this paper is to introduce the implant mediated drug delivery system as a novel application of endosseous implants. The system is composed of hollow cylindric implants which has multiple microholes for drug delivery. For this purpose, the general outlines of drug delivery system and drug delivery route is discussed briefly. In addition, this paper deals with the results of experiments done up to now and the future perspective of the system.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

Prognosis after treatment with multiple dental implants under general anesthesia and sedation in a cerebral palsy patient with mental retardation: A case report

  • Hong, Young-Joon;Dan, Jung-Bae;Kim, Myung-Jin;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권2호
    • /
    • pp.149-155
    • /
    • 2017
  • Cerebral palsy is a non-progressive disorder resulting from central nervous system damage caused by multiple factors. Almost all cerebral palsy patients have a movement disorder that makes dental treatment difficult. Oral hygiene management is difficult and the risks for periodontitis, dental caries and loss of multiple teeth are high. Placement of dental implants for multiple missing teeth in cerebral palsy patients needs multiple rounds of general anesthesia, and the prognosis is poor despite the expense. Therefore, making the decision to perform multiple dental implant treatments on cerebral palsy patients is difficult. A 33-year-old female patient with cerebral palsy and mental retardation was scheduled for multiple implant treatments. She underwent computed tomography (CT) under sedation and the operation of nine dental implants under general anesthesia. Implant-supported fixed prosthesis treatment was completed. During follow-up, she had the anterior incisors extracted and underwent the surgery of 3 additional dental implants, completing the prosthetic treatment. Although oral parafunctions existed due to cerebral palsy, no implant failure was observed 9 years after the first implant surgery.

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

  • Kim, Min-Jeong;Hong, Sung-Ok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.85-93
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone.