• Title/Summary/Keyword: Dental Implant System

Search Result 330, Processing Time 0.029 seconds

Controlled release of nerve growth factor from heparin-conjugated fibrin gel within the nerve growth factor-delivering implant

  • Lee, Jin-Yong;Kim, Soung-Min;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.3-10
    • /
    • 2014
  • Objectives: Although nerve growth factor (NGF) could promote the functional regeneration of an injured peripheral nerve, it is very difficult for NGF to sustain the therapeutic dose in the defect due to its short half-life. In this study, we loaded the NGF-bound heparin-conjugated fibrin (HCF) gel in the NGF-delivering implants and analyzed the time-dependent release of NGF and its bioactivity to evaluate the clinical effectiveness. Materials and Methods: NGF solution was made of 1.0 mg of NGF and 1.0 mL of phosphate buffered saline (PBS). Experimental group A consisted of three implants, in which $0.25{\mu}L$ of NGF solution, $0.75{\mu}L$ of HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin was injected via apex hole with micropipette and gelated, were put into the centrifuge tube. Three implants of experimental group B were prepared with the mixture of $0.5{\mu}L$ of NGF solution, $0.5{\mu}L$ HCF, $1.0{\mu}L$ of fibrinogen and $2.0{\mu}L$ of thrombin. These six centrifuge tubes were filled with 1.0 mL of PBS and stirred in the water-filled beaker at 50 rpm. At 1, 3, 5, 7, 10, and 14 days, 1.0 mL of solution in each tubes was collected and preserved at $-20^{\circ}C$ with adding same amount of fresh PBS. Enzyme-linked immunosorbent assay (ELISA) was done to determine in vitro release profile of NGF and its bioactivity was evaluated with neural differentiation of pheochromocytoma (PC12) cells. Results: The average concentration of released NGF in the group A and B increased for the first 5 days and then gradually decreased. Almost all of NGF was released during 10 days. Released NGF from two groups could promote neural differentiation and neurite outgrowth of PC12 cells and these bioactivity was maintained over 14 days. Conclusion: Controlled release system using NGF-HCF gel via NGF-delivering implant could be an another vehicle of delivering NGF to promote the nerve regeneration of dental implant related nerve damage.

Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향)

  • Shin, Hyon-Mo;Cho, Wook;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • The purpose of this study was to clarify the clinical efficiency of tungsten carbide/carbon coating on obtaining optimal preload of abutment screw compared with non-coated screw in external-hex implant system. In the present work, rotational value and the compressive force between abutment and fixture of abutment screws without coating and with coating tightened to 30Ncm were measured. Mean compressive force of coated screw was 504.6N. Then uncoated screw was tightened to clamping the abutment and the implant to 504.6N, and the tightening torque value and the rotational value was recorded. The following conclusions were drawn within the limitation of this study. Compressive force of coated screw was higher than that of uncoated screw after tightening at 30Ncm. The tightening torque that was nedeed to clamping the uncoated screw equal to coated screw tightened to 30Ncm was 55.6Ncm. In case of equal compressive force, there was no significant difference in rotation value between coated and uncoated screw.

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

A Survey on Preliminary Dental Hygienists' Senses of Employment (예비치과위생사의 취업에 관한 의식 조사)

  • Han, Su-Jin;Lee, Sun-Mi;Lim, Mi-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.583-594
    • /
    • 2007
  • The purpose of this study was to conduct a survey on the senses that preliminary dental hygienists have on employment, who applied for the National Dental Hygienist Examination, so that it could provide a basic reference required for fostering good human resources specializing in oral health with a sense of mission and responsibility as professional. To meet these goals, a self-administered questionnaire survey was conducted for participants in a refresher education meeting for preliminary dental hygienists across three major regions(Seoul, Daejeon and Busan), which was held by the Korean Dental Hygienists Association(KDHA) on Jan. 15, 2006. Total 289 sheets of questionnaire were collected, and 262 sheets except invalid or incomplete ones were used for examination and analysis. As a result, this study came to the following conclusions: First, it was found that 40.4% respondents wanted to be employed in dental clinic or hospital. Most respondents(90.1%) answered that faithfulness is most valued as prerequisite qualification for employment in hospital, and highest percentage of respondents(39.3%) wanted to earn 16 to 17 million Korean won annually. For internship opportunities, 61.9% respondents replied that they could willingly accept the internship, provided that basic pay and switchover to regular employee are all assured. Second, as the results of survey on employment circumstances around respondents, it was found that most respondents(58.3%) were employed in dental clinic or hospital, and highest percentage of respondents(35.0%) earned 15 to 16 million Korean won. Third, it was found that interpersonal relationships among employees had most significant effects(4.81) on selection of employment, which was followed by in-house welfare benefits 1(monthly/annual vacation, resting room, etc; 4.56). For possible influential factors on the selection of employment depending on whether employed or not, it was found that there were Significant differences in pay, welfare benefit 2(seminar, orientation, refresher training opportunities, etc), post-wedding continued employment and merit system between employees and non-employees(pE0.05). Fourth, the survey on respondents' occupational senses of dental hygienist showed that major tasks of dental hygienists were represented by oral disease prevention(92.6%), case management(71.5%), oral health education(66.3%), hospital/clinic management and dental management support(10.4%) and public oral health activities(6.7%) respectively. For job satisfaction, it was found that almost half respondents(48.9%) showed satisfaction at their job and 32.6% felt satisfied at and proud of their job. That is, majority of respondents(81.5%) felt satisfied at their job as dental hygienist. For follow-up requirements to qualify for dental hygienists, it was found that 73.3% felt it necessary to give more investments to self-development, 62.2% respondents considered protection of membership's rights as one of future assignments that KDHA should be more committed to. For future social awareness about dental hygienists as occupation, 69.2% respondents expected that they would be better developed and treated as professional. And desired training courses as a part of qualification for professional dental hygienists were represented by case management(services, manners, etc; 33.3%), implant(28.9%), esthetics(correction, prosthesis, whitening; 18.9%) and so on. For an item on working years, it was noted that 75.9% respondents would keep working as dental hygienists as long as they could.

  • PDF

CLINICAL STUDY OF MAXILLOFACIAL PROSTHESES;OSSEOINTEGRATED IMPLANTS FOR MAXILLOFACIAL PROSTHESES (악안면 보철의 임상적 고찰;골내 매식술을 통한 보철적 회복에 관하여)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.406-414
    • /
    • 2001
  • In recent decade, there has been a very rapid development in technical possibilities to provide patients with maxillofacial prostheses. Dr. Brenemark first introduced possibility of use of maxillofacial interosseous implant in patients with ablative tumor surgery in 1979. He did introduce the new type of maxillofacial implants system which widen the fixture flange on top of the bone. The advantages of fixed prostheses with implants were well known to various ways, easy to attach, keep clean prostheses, and not to disturb recipient bed. But there are some problems to install implants on maxillofacial regions, because mostly facial bone has very thin cortical bone and poor bone quality. It needs more retention between implant and bone which overcome that fault with fixture flange. To make maxillofacial prostheses, it should be understood general procedure of maxillofacial laboratory work. Ear and midface maxillofacial fabrication which include nose and eye defects will be described step by step.

  • PDF

Design and Evaluation of Osseointegration Analysis System for Dental Implant (치과 임플란트용 골융합 측정기의 설계 및 평가)

  • Lee, Joo-Hee;Kim, Chang-Il;Kim, Chul-Min;Paik, Jong-Hoo;Cho, Jeong-Ho;Chun, Myoung-Pyo;Jeong, Young-Hun;Lee, Jeong-Bae;Lee, Seung-Dae;Lee, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.295-295
    • /
    • 2010
  • 생체 식립형 임플란트의 경우 성공도는 매식체의 골유착 정도에 크게 영향을 받는다. 골유착 시 임플란트의 표면 형상과 하중, 골질의 양 등 많은 요인에 영향을 받게 되므로, 임플란트의 안정성을 주기적으로 점검해야할 필요가 있다. 따라서 임플란트 안정성을 공진 주파수 분석법을 이용하여 측정하기 위해 압전소자 제작과 트랜스듀서의 구조를 설계하였다. 유한요소 해석을 통하여 압전소자와 트랜스듀서의 두께와 크기 변화를 통해 측정 주파수 범위를 10kHz대역으로 맞추었으며, 해석 결과를 토대로 샘플제작과 평가를 실시하였다. 평가 결과 시뮬레이션 해석결과와 유사한 10kHz의 주파수 대역을 가지는 것을 볼 수 있었고, 식립된 나사의 고정도가 증가할수록 주파수가 점차 증가하는 결과를 얻을 수 있었다.

  • PDF

A COMPARISON OF ACCURACY BETWEEN FIXTURE IMPRESSION AND ABUTMENT IMPRESSION FOR DENTAL IMPLANTS (치과 임플랜트용 고정체 인상법과 지대원주 인상법간의 정확성 비교)

  • Choi, Hyun-Sik;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.662-673
    • /
    • 1997
  • The purpose of this study was to compare the accuracy between future impression and abutment impression using strain gauges. The master model used in this study was a partially edentulous mandibular metal cast with two fixture analogs on both sides. On the left, two future analogs were parallel, whereas right side, posterior future analog exhibiting a 15-degree lingual inclination. From master cast, 10 impressions were made for each of the three impression methods. The master frameworks was fabricated on the master model, and two-element strain gauge was attached to a master framework. The master framework was seated on each cast, and gold screws were tightened to 10 Ncm using a torque controller AI-1600 strain measurement system was used for strain measuring. Impression methods studied were : Group 1:abutment impression Group 2:fixture impression Group 3:combined impression (anterior:fixture impression, posterior:abutment impression) The results were as followed. 1. The strain values on X-axis and Y-axis according to the three impression methods showed no significant difference. 2. The strain values on parallel and angulated groups according to the three impression methods showed no significant difference. 3. The parallel group exhibited significantly higher accuracy in adaptation than angulated group for all experimental groups (p<0.05). In conclusion, it is considered that accuracy of implant prostheses is more affected by implant angulation than impression methods.

  • PDF

THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS (주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구)

  • Oh Su-Yeon;Vang Mong-Sook;Yang Hong-So;Park Sang-Won;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

Retrospective Clinical Study of Immediate or Early Loading of Implants (Original Article 1 - 즉시 혹은 조기하중 임프란트에 관한 후향적 연구)

  • Lee, Seong-Yeon;Kim, Young-Kyun;Yun, Pil-Young;Yi, Yang-Jin;Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 2010
  • Introduction. In this study, we applied the immediate loading to implant using temporary prosthesis, and compared the treatment results by each placement site, amongst pre-loading period. The study was intended to search for occurrence of complications and the amount of marginal bone resorption. Materials and Methods. We retrospectively reviewed the medical records of 99 cases of implants from 29 patients who were treated at Seoul National University Bundang Hospital from September 2003 to September 2008. We grouped all the cases by placement arches and pre-loading periods, and subdivided each group by placement site(anterior/posterior), type of prosthesis(full-mouth cross splinting/Partial multiple splinting, Single). Results. In the cases of anterior maxilla, the average amounts of marginal bone resorption showed $1.71{\pm}0.71mm$ in group 1, and $1.44{\pm}0.69mm$ in group 2, which means they revealed no statistically significant difference between group 1 and group 2(p=0.646). In the cases of posterior maxilla, the average amounts of marginal bone resorption showed $1.25{\pm}0.72mm$ in group 1, and $1.14{\pm}1.15mm$ in group 2, which means they were not statistically significant. In the cases of anterior mandible, there was no cases classified as group 4, but the average amounts of marginal bone resorption in group 3 showed $1.38{\pm}0.79mm$. In the cases of posterior mandible, Group 3 showed $1.39{\pm}0.64mm$, and group 4 showed $1.84{\pm}1.19mm$ as amounts of marginal bone resorption, which means they revealed no statistically significant difference between group 3 and group 4(P=0.210). The survival rate of group1 was 97.14%, 92.1% of group3, and 100% of group 2 and group4. According to each type of prosthesis, each average amount of marginal bone resorption revealed no statistically significant difference in maxi11a(p=0.575) in mandible(p=0.206). Conclusion. It is concluded that the marginal bone resorption and the rate of complications might not be affected by placement sites and pre-loading periods. The marginal bone resorption and the rate of complications might vary as different bone quality of placement site and implant system, diameter, length, etc. It is suggested that the proper placement of immediate loading implants decreases the whole treatment period and any inconvenience occurred to patients.