• Title/Summary/Keyword: Dental Implant Material

Search Result 367, Processing Time 0.021 seconds

HISTOLOGICAL COMPARISONS OF TITANIUM PLASMA SPRAYED IMPLANT AND HYDROXYAPATITE COATED IMPLANT TO BONE INTERFACE IN PERIODONTALLY INVOLVED EXTRACTION SOCKETS IN DOGS (성견 치주질환 이환 발치와에 즉시 임플란트 매식술시 Titanium plasma sprayed 임프란트와 Hydroxyapatite coated 임프란트의 계면조직에 관한 연구)

  • Kim, Jin-Sook;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.400-410
    • /
    • 1993
  • Dental implants have been widely used in the treatment of esthetic and functional problems of the mouth due to alveolar bone loss, after tooth extraction. The success of implantation strongly depends on osseointegration. For osseointegration, implant material, methodology, and design have been investigated. For materials, two popular materials at present are titanium and hydroxyapatite. For methods, immediate implantation is being used recently. The purpose of this study is to evaluate osseointegration between the unthreaded cylindrical TPS implant and the HA-coated implant by a histomorphometric analysis. For this analysis, experimental periodontits was induced on the 3, 4 premolars of adult dogs by the ligation of orthodontic threads. Thereafter, each tooth was extracted. TPS. Implants and HA-coated implants were immediately inserted in the extraction socket. In control group, TPS implants were immediately inserted, and In experimental group, HA implants were immediately inserted. The dogs were sacrificed after 12 weeks, then the specimens were prepared for LM and histomorphometric analysis. The conclusion of this study is as follows l. In both control and experimental group, no inflammatory cells were observed. 2. The results of the histomorphometric analysis showed that the total osseointegration was 48.5% in control group, and 68.8% in expermental group. The experimental group was higher than the control group, and the difference was not statistically significant (p<0.05). 3. The results of the histomorphometric analysis showed that the osseointegration in the hole was 40.6% in control group, and 70.2% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). In both control and experinental group, no inflammatory cells were observed. 4. The results of the histomorphometric analysis showed that the osseointegration in the lower part was 52.1% in control group, and 73.3% in experimental group. The experimental group was higher than the control group, and the difference was statistically significant (p<0.05). 5. In experimental group, the bone to HA interface seemed to be mixed of bone and HA. We could not distinguish HA from the bone. The HA coating was detached from the titanium surface.

  • PDF

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

Sinus bone graft and simultaneous vertical ridge augmentation: case series study

  • Kang, Dong-Woo;Yun, Pil-Young;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.36.1-36.8
    • /
    • 2019
  • Background: This study aims to examine the outcome of simultaneous maxillary sinus lifting, bone grafting, and vertical ridge augmentation through retrospective studies. Methods: From 2005 to 2010, patients with exhibited severe alveolar bone loss received simultaneous sinus lifting, bone grafting, and vertical ridge augmentations were selected. Fifteen patients who visited in Seoul National University Bundang Hospital were analyzed according to clinical records and radiography. Postoperative complications; success and survival rate of implants; complications of prosthesis; implant stability quotient (ISQ); vertical resorption of grafted bone after 1, 2, and 3 years after surgery; and final observation and marginal bone loss were evaluated. Results: The average age of the patients was 54.2 years. Among the 33 implants, six failed to survive and succeed, resulting in an 81.8% survival rate and an 81.8% success rate. Postoperative complications were characterized by eight cases of ecchymosis, four cases of exposure of the titanium mesh or membrane, three cases of periimplantitis, three cases of hematoma, two cases of sinusitis, two cases of fixture fracture, one case of bleeding, one case of numbness, one case of trismus, and one case of fixture loss. Prosthetic complications involved two instances of screw loosening, one case of abutment fracture, and one case of food impaction. Resorption of grafted bone material was 0.23 mm after 1 year, 0.47 mm after 2 years, 0.41 mm after 3 years, and 0.37 mm at the final observation. Loss of marginal bone was 0.12 mm after 1 year, and 0.20 mm at final observation. Conclusions: When sinus lifting, bone grafting, and vertical ridge augmentation were performed simultaneously, postoperative complications increased, and survival rates were lower. For positive long-term prognosis, it is recommended that a sufficient recovery period be needed before implant placement to ensure good bone formation, and implant placement be delayed.

THREE-DIMENTIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION FOR DIFFERENT IMPLANT THREAD SLOPE (임플랜트 나사선 경사각이 치조골 응력 분포에 미치는 영향)

  • Seo, Young-Hun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.482-491
    • /
    • 2007
  • Statement of problem: The screws of dental implant, having various thread types, can be categorized into different classes by their geometrical form, and each type transmits dissimilar amount and form of stress to alveolar bone. Purpose: The purpose of this study was to find an inclination angle of the screw thread that is favorable in distributing the stresses to alveolar bone. Material and methods: In this study, We used three dimensional finite element analysis with modeling having three types of thread inclination angles and fixed pitch-0.8 mm (single thread type with $3.8^{\circ}$ inclination, double thread type with $7.7^{\circ}$ inclination, triple thread type with $11.5^{\circ}$ inclination). Results: The results obtained from this study were as follows; 1. When the number of thread increased, the amount of Von-Mises stress was reduced since the generated stress was effectively distributed. 2. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants when comparing the magnitude of the maximum principal stress double thread had least amount of stress. This shows that the double thread screw gave best result. Conclusion: In conclusion, double, and triple thread screws were found to be more effective on distribution of the stress than the single thread screws. But, increasing in the thread inclination angle such as triple thread screw relate on the magnitude of the maximum principal stress affecting on the alveolar bone can become problematic. Thus, effective combination of thread number and thread inclination angle can help prolonging the longevity of implant.

Fracture Analysis of Implant Components using Scanning Electron Microscope - Part I : Implant Fixture (임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 - Part I: 임플란트 고정체)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.297-309
    • /
    • 2010
  • The objective of the present study was to perform a fracture analysis on fractured implant fixture after use in vivo and make clear the cause & mechanisms of failure. In case of fatigue fracture, the fractured surface represents fatigue striation. Fatigue striation indicate the progression of the crack front under cyclic loading, are characteristic of stage 2 crack growth. The site of crack initiation and stage 1 crack growth were not easily identified in any of the failure, presumably because of the complex microstructural features of the polycrystalline sample. In case of fractured by overload, dimpled or cleavage surface were observed. Using the interpretation of characteristic markings(ratchet mark, fatigue striation, dimple, cleavage et al) in fracture surfaces, failure events containing the crack origin, crack propagation, material deficiency could be understand.

SURVIVAL RATE OF THE DENTAL IMPLANTS PLACED IN POSTERIOR MAXILLA WITHOUT SINUS AUGMENTATION (상악동 골이식술 없이 상악 구치부에 식립된 임프란트의 생존율)

  • Park, Hye-Won;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.3
    • /
    • pp.170-175
    • /
    • 2009
  • Purpose : The purpose of this study is to evaluate 7-year survival rate of implants placed without bone graft in posterior maxilla and compare the survival rate by the age and gender of patient, length and diameter of implant, region of implant placement, bicortical engagement of fixture, and connection of prosthesis. Material and methods : 78 patients (170 implants) who visited our institution from 2002 to 2007 and were followed up with panoramic view and medical records. Kaplan-Meier survival analysis and Log Rank (Mantel-Cox) test were used. Results and conclusions : A 7-year cumulative survival rate for implants placed in posterior maxilla without sinus graft was 95.3%. The survival rate in men was 91.8%, significantly lower than 98.8% in woman.(p<0.05). However, the survival rate by the length of the implants did not show any significant differences.(p>0.05), while the wide platform implant resulted in 85% survival rate which was statistically lower than 98.5% in regular platform. The posterior maxillary implants engaged bicortically showed 97.6% of 7-year Survival rate, comparing 88.6% in not engaged implants. The survival rate of the single implant was 91.2%, while 98.5% in splinted prosthesis. Therefore, the bicortical engagement of the fixtures and splinted prosthesis may be recommended to get a long-term survival rate in posterior maxilla.

Horizontal ridge augmentation with porcine bone-derived grafting material: a long-term retrospective clinical study with more than 5 years of follow-up

  • Jin-Won Choi;Soo-Shin Hwang;Pil-Young Yun;Young-Kyun Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.6
    • /
    • pp.324-331
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the outcomes of implants placed in horizontally augmented alveolar ridges using porcine bone grafts and to investigate the long-term stability of the porcine bone grafts. Materials and Methods: A retrospective analysis was conducted on 49 sites that underwent horizontal ridge augmentation using porcine bone grafts and implant placement with a follow-up period longer than 5 years. Furthermore, additional analysis was conducted on 24 sites where porcine bone grafts were used exclusively for horizontal ridge augmentation and implant placement. Results: The mean follow-up period after prosthesis loading was 67.5 months, with a mean marginal bone loss of 0.23 mm at 1 year and a cumulative mean marginal bone loss of 0.40 mm over the entire follow-up period. Of the 49 implants, 2 were lost and 3 did not meet the success criteria, resulting in a survival rate of 95.9% and a success rate of 89.8%. In 24 sites, the mean marginal bone loss was 0.23 mm at 1 year and 0.41 mm at 65.8 months, with 100% survival and success rates. Conclusion: Porcine bone grafts can be successfully used in horizontal ridge augmentation for implant placement in cases of ridges with insufficient horizontal width.

Pro-inflammatory cytokine expression in human gingival fibroblasts by Tannerella forsythia whole bacteria, membrane proteins, and lipopolysaccharide (사람 치은 섬유아세포에서의 Tannerella forsythia 전세균, 막단백질, 당지질에 의한 염증성 사이토카인 발현)

  • Kim, Jung-Eun;Lee, Sung-Hoon;Choi, Bong-Kyu;Koo, Ki-Tae;Kim, Tae-Il;Lee, Yong-Moo;Ku, Young;Chung, Chong-Pyoung;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.543-550
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate induction of cytokine expression in human gingival fibroblasts (HGFs) by whole cell and the components of T. forsythia. Material and Methods: After HGFs were treated with lipopolysaccharide (LPS), membrane protein isolated from T. forsythia or culture media of T. forsythia, the induction of interleukin (IL)-1, IL-6 and IL-8 was examined with real-time PCR and ELISA. Their induction ability of cytokines was compared with whole bacteria. Result: The expression of IL-6 and IL-8 was significantly induced in HGFs by whole bacteria and membrane protein. The expression of IL-$1{\beta}$ was induced by membrane protein of T. forsythia, not by whole bacteria. LPS and condition media of T. forsythia slightly activated HGFs. Conclusion: The membrane protein of T. forsythia could be one of virulence factors.

Assessment of stem cell viability in the initial healing period in rabbits with a cranial bone defect according to the type and form of scaffold

  • Kang, Seung-Hwan;Park, Jun-Beom;Kim, InSoo;Lee, Won;Kim, Heesung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.4
    • /
    • pp.258-267
    • /
    • 2019
  • Purpose: Increased bone regeneration has been achieved through the use of stem cells in combination with graft material. However, the survival of transplanted stem cells remains a major concern. The purpose of this study was to evaluate the viability of transplanted mesenchymal stem cells (MSCs) at an early time point (24 hours) based on the type and form of the scaffold used, including type I collagen membrane and synthetic bone. Methods: The stem cells were obtained from the periosteum of the otherwise healthy dental patients. Four symmetrical circular defects measuring 6 mm in diameter were made in New Zealand white rabbits using a trephine drill. The defects were grafted with 1) synthetic bone (${\beta}$-tricalcium phosphate/hydroxyapatite [${\beta}-TCP/HA$]) and $1{\times}10^5MSCs$, 2) collagen membrane and $1{\times}10^5MSCs$, 3) ${\beta}-TCP/HA+collagen$ membrane and $1{\times}10^5MSCs$, or 4) ${\beta}-TCP/HA$, a chipped collagen membrane and $1{\times}10^5MSCs$. Cellular viability and the cell migration rate were analyzed. Results: Cells were easily separated from the collagen membrane, but not from synthetic bone. The number of stem cells attached to synthetic bone in groups 1, 3, and 4 seemed to be similar. Cellular viability in group 2 was significantly higher than in the other groups (P<0.05). The cell migration rate was highest in group 2, but this difference was not statistically significant (P>0.05). Conclusions: This study showed that stem cells can be applied when a membrane is used as a scaffold under no or minimal pressure. When space maintenance is needed, stem cells can be loaded onto synthetic bone with a chipped membrane to enhance the survival rate.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.