• Title/Summary/Keyword: Dental Computer-Aided-Design

Search Result 198, Processing Time 0.018 seconds

Computer-aided design and manufacturing-based full mouth rehabilitation for a patient with excessive attrition and restricted vertical dimension: A case report (심한 치아 마모와 수복 공간 부족을 보이는 환자에서 CAD/CAM 기술을 활용한 완전 구강 회복: 증례 보고)

  • Cho, Jun-Ho;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.495-505
    • /
    • 2019
  • This study reported the treatment of a patient with excessive worn dentition and limited maxillo-mandibular space for restoration, utilizing the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. After the thorough examination of the patient's occlusal vertical dimension (OVD), full mouth rehabilitation was planned with increase of the OVD. The patient was satisfied with the provisional restorations establishing the increased OVD. The horizontal and vertical data of the patient's jaw relation that the provisional restorations contained were transferred to the definitive metal ceramic fixed prostheses by double scanning and three-dimensional printing. After the fixed restorations were cemented to the abutments, electronic surveying and three-dimensional printing were used to fabricate metal frameworks for the patient's removable partial dentures. The mandibular definitive removable prostheses were delivered to the patient's mouth and the full mouth rehabilitation procedures were completed. The digital technologies used for this case produced fixed and removable restorations satisfactory in masticatory, phonetic and aesthetic functions to both the patient and the dental clinician.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing

  • Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.2.1-2.7
    • /
    • 2018
  • With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Marginal and internal fit according to the shape of the abutment of a zirconia core manufactured by computer-aided design/computer-aided manufacturing (CAD/CAM으로 제작된 지르코니아 코어의 지대치 형태에 따른 변연 및 내면 적합도에 관한 연구)

  • Kim, Ji-Su;Ryu, Jae-Kyung
    • Journal of Korean Dental Hygiene Science
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2022
  • Background: In this study, zirconia copings were fabricated by setting clinically acceptable inner values for prostheses using computer-aided design/computer-aided manufacturing (CAD/CAM). The processed copings were evaluated for the marginal and internal fit of each abutment shape with a CAD program using the silicone replica technique. Methods A total of 20 copings was produced by selecting models commonly used in clinical practice. After injecting the sample, the minimum thickness, internal adhesion interval, and distance to the margin line were set to 0.5, 0.05, and 1.00 mm using a dental CAD program, respectively. It was measured using a 2D section function in a three-way program of the silicon replication technology. Although the positions and number of measurements of the anterior and posterior regions differed, nine parts of each pre-tube were designated and measured by referring to a previous study to compare the two samples. Results As a result, the average margin of the mesial, distal, and buccal (labial) surfaces was 59.90 ㎛ in the anterior region and 60.40 ㎛ in the posterior region. The mean axial wall margin was 67.25 ㎛ in the anterior region and 69.25 ㎛ in the posterior region. In occlusion, the anterior teeth (77.70 ㎛), posterior teeth (77.60 ㎛), and both anterior and posterior regions were within the clinically acceptable range. Conclusion The edge and inner fit of zirconia coping manufactured using the CAD/CAM system showed clinically applicable results. To reduce errors and increase accuracy, materials and machine errors that affect the manufacture of prosthetics should be investigated. Based on our results, the completeness of prosthetics could increase if the inner value and characteristics of the material are adjusted when applied in clinical practice.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.