• Title/Summary/Keyword: Dental Casting Technique

Search Result 40, Processing Time 0.027 seconds

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

  • Park, Jong-Kyoung;Lee, Wan-Sun;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.122-128
    • /
    • 2015
  • PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (${\alpha}$=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (< $120{\mu}m$). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

Interface Phenomena between Prosthodontic Crown and Abutment Sprayed with Die Spacer (Die Spacer가 도포된 보철용 크라운과 어버트먼트의 계면현상)

  • Park, K.H.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.4
    • /
    • pp.197-202
    • /
    • 2007
  • Fit of the restoration and its cementation procedure is crucial to both its short and long term prognosis. Marginal fit is affected by many variables during the fabrication process. These variables, being intrinsic properties of the materials or the clinical technique used, can cause changes in the size and shape of the definitive restoration. Even if all variables are controlled carefully, the seating of a restoration can still be affected due to insufficient space for the luting agent. The use of die spacer can reduce the elevation of a cast restoration of a prepared tooth, decreased seating time, improve the outflow of excess cement, and lower the seating forces. The purpose of this study was to evaluate the marginal fidelity according to die spacer application times and measurement site. Casting alloys were prepared and fabricated using non-precious metal at $950^{\circ}C$. Specimens are divided into four groups: I(die spacer painted casting for wax pattern), II(die spacer non painted casting for wax pattern). The specimens were cut and polished for marginal gap observation. The marginal gap was observed using scanning electron microscopy (SEM).

An evaluation of marginal fit of resin single crown manufactured using a dental 3D printer (치과용 3D 프린터를 활용해 제작된 레진 단일치관보철의 변연적합 평가)

  • Ki-Baek Kim
    • Journal of Technologic Dentistry
    • /
    • v.44 no.4
    • /
    • pp.126-131
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the quality of dental fixed prostheses fabricated by 3DP (three-dimensional printing). Methods: Ten main models were prepared for the study. Ten specimens were printed by 3DP (3DP group). Ten specimens were fabricated by the lost wax technique and casting method to complete the control group (LWC group). The marginal fit was measured for 20 specimens. The measurement of marginal fit was performed using the silicon replica technique. Finally, the marginal fit of 10 specimens from each group was calculated. An independent sample t-test was run to see if the calculated averages for the two groups were mutually significant (α=0.05). Results: According to the experimental results, the mean marginal fit of the 3DP group was 71.9 ㎛, and the LWC group was 55.3 ㎛. The means of the two groups were found to be significantly different (p<0.001) in the results of the independent sample t-test. Conclusion: The marginal fit of fixed dental prostheses produced by 3DP technology was examined with values greater than those fabricated by traditional technology. However, as it appeared to be a value within the range of clinically acceptable range recommended by numerous studies, it was determined that clinical application would be feasible.

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

Evaluation of clinical adaptation of dental prostheses printed by 3-dimensional printing technology (3D 프린팅 기술로 출력된 치과 보철물의 임상적 적합도 평가)

  • Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Purpose: The objectives of this study was to evaluate clinical adaptation of dental prostheses printed by 3 dimensional(3D) printing technology. Methods: Ten study models were prepared. Ten specimens of experimental group were printed by 3D printing(3DP group). As a control group, 10 specimens were fabricated by casting method on the same models. Marginal gaps of all specimens were measured to evaluate clinical adaptation. Marginal adaptations were measured using silicone replica technique and measured at 8 sites per specimen. Wilcoxon's signed-ranks test was used for statistical analysis(${\alpha}=0.05$). Results: Means of marginal adaptations were $95.1{\mu}m$ for 3DP group and $75.9{\mu}m$ for CAST group(p < 0.000). Conclusion : However, the mean of the 3DP group was within the clinical tolerance suggested by the previous researchers. Based on this, dental prosthesis fabricated by 3D printing technology is considered to be clinically acceptable.

A study of introduction for using Laser in dental prosthesis (치과보철영역에 레이저 이용을 위한 이론적 고찰)

  • Park, Myoung-Ho;Bae, Bong-Jin;Lee, Hwa-Sik
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.131-139
    • /
    • 2008
  • It's very important to find the most appropriate adhesion technique available, taking into consideration factors such as biocompatibility, non-corrosiveness, mechanical stability, etc. Laser welding is the best choice you can make because from a mechanical viewpoint, a laser welded surface has better particle structure than does a casted particle structure. Furthermore, it requires no additional material and the same metal alloy which is used when casting can be used. Therefore, the resulting mixture will consist of a single alloy, instead of utilizing different alloy combinations. Another benefit is the low economic cost. The most beneficial aspects of laser welding is that it is biologicallly friendlly, doesn't require soldering, can fuse different metal alloys together, and can weld on heat-sensitive spots(E.g. around resin or ceramic). A consistent strong pulse is possible. This technique is capable of welding on master models and creates accurate welds. It is capable of due to its stronger, non-corrosive microscope, which allows 25times magnification during the soldering process. This is possible because of its high stability from the tiny particle structure.

  • PDF

Evaluation of marginal and internal fit of metal copings fabricated by selective laser melting (SLM 방식으로 제작한 도재관 금속하부구조물의 변연 및 내면 적합도 평가)

  • Sung-Ryung Bae;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: To evaluate the marginal and internal fit of metal coping fabricated by a metal three-dimensional (3D) printer that uses selective laser melting (SLM). Methods: An extraoral scanner was used to scan a die of the prepared maxillary right first molar, and the coping was designed using computer-aided design software and saved as an stereo lithography (STL) file. Ten specimens were printed with an SLM-type metal 3D printer (SLM group), and 10 more specimens were fabricated by casting the castable patterns output generated by a digital light processing-type resin 3D printer (casting the 3D printed resin patterns [CRP] group). The fit was measured using the silicon replica technique, and 8 points (A to H) were set per specimen to measure the marginal (points A, H) and internal (points B~G) gaps. The differences among the groups were compared using the Mann-Whitney U-test (α=0.05). Results: The mean of marginal fit in the SLM group was 69.67±18.04 ㎛, while in the CRP group was 117.10±41.95 ㎛. The internal fit of the SLM group was 95.18±41.20 ㎛, and that of the CRP group was 86.35±32 ㎛. As a result of statistical analysis, there was a significant difference in marginal fit between the SLM and CRP groups (p<0.05); however, there was no significant difference in internal fit between the SLM group and the CRP group (p>0.05). Conclusion: The marginal and internal fit of SLM is within the clinically acceptable range, and it seems to be applicable in terms of fit.

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

Evaluation of Marginal Gap of Three Unit Metal Cores Fabricated by 3-Dimensional Printing Technique (3차원 프린팅 기술에 의해 제작된 3본 금속 코어의 변연 간격 평가)

  • Kim, Jae-Hong;Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.196-201
    • /
    • 2015
  • The purpose of this study was to evaluate marginal gap of 3 unit fixed dental prostheses (FDPs) fabricated by 3-dimensional (3D) printing technology and to compare marginal gap of its by a conventional method (lost wax technique and casting method). Ten study models were manufactured. Three unit FDPs were fabricated by 3D printing technique (3D group) and conventional methods (CV group). Marginal gaps were measured by silicone replica technique and digital microscope (${\times}160$). Mann-Whitney test was executed (${\alpha}=0.05$). The mean${\pm}$standard deviation of marginal gap for premolars and molars were $112.5{\pm}8.6{\mu}m$ and $110.2{\pm}7.0{\mu}m$ in the 3D group and $83.2{\pm}4.4{\mu}m$ and $82.2{\pm}4.6{\mu}m$ in the CV group. There were statistically significant differences (p<0.05). As results, clinical application further improvement of 3D printing technique may be required.

An analysis of marginal adaptation of metal cores fabricated by selective laser sintering (레이저선택용융기술에 의해 제작된 금속 코어의 변연 적합도 분석)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.305-311
    • /
    • 2016
  • Purpose: The purpose of this study were to analysis of marginal adaptation of metal cores fabricated by selective laser sintering. Methods: Main model was prepared and ten stone models were fabricated. Ten single metal cores were fabricated by selective laser sintering(SLS group) and another ten single metal cores using lost wax technique and casting method were manufactured(CAST group). The marginal adaptation of metal cores were analysis using by the silicone replica technique. Silicone replicas were sectioned two times. The marginal adaptations were measured using by digital microscope. Statistical analyses was performed with independent t-test(${\bullet}{\cdot}=0.05$). Results: Means of marginal adaptations were 90.3 ${\ss}{\uparrow}$ for SLS group and 65.1 ${\ss}{\uparrow}$ for CAST group. Two groups were statistically significant differences (p < 0.05). Conclusion: Marginal adaptation of metal cores fabricated by selective laser sintering were ranged within the clinical recommendation.