1 |
Lee HE, Moon HR. Recognition and awareness of the need for education among dental laboratory technology students during the 4th industrial revolution of the healthcare field. J Tech Dent. 2022;44:47-52.
DOI
|
2 |
Kim DY, Lee GY. Comparison of polymerization by time of light curing for dental 3D printing. J Tech Dent. 2022;44:76-80.
DOI
|
3 |
Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J. 2009;28:44-56.
DOI
|
4 |
Kim JH, Kim KB. Internal evaluation of provisional restorations according to the dental CAD/CAM manufacturing method: three-dimensional superimpositional analysis. J Korean Acad Dent Technol. 2019;41:81-86.
DOI
|
5 |
Kim JH, Kim KB. Evaluation the clinical acceptability of the marginal and internal gaps of fixed partial denture fabricated with additive manufacturing technology. J Korean Acad Dent Technol. 2018;40:209-215.
|
6 |
Park YD, Kang W. Comparative evaluation of the fitness of anterior and posterior interim crowns fabricated by additive manufacturing. J Tech Dent. 2021;43:153-159.
DOI
|
7 |
Noh MJ, Lee HB, Kim JH. Evaluation of marginal and internal accuracy of provisional crowns manufactured using digital light processing three-dimensional printer. J Tech Dent. 2022;44:31-37.
DOI
|
8 |
Kim DY, Lee GY. Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization. J Tech Dent. 2021;43:84-92.
DOI
|
9 |
Kokubo Y, Nagayama Y, Tsumita M, Ohkubo C, Fukushima S, Vult von Steyern P. Clinical marginal and internal gaps of in-ceram crowns fabricated using the GN-I system. J Oral Rehabil 2005;32:753-758.
DOI
|
10 |
Kim JH, Kim KB. An evaluation validity of the silicone replica technique at measurement on fit of fixed dental prostheses. J Dent Hyg Sci. 2012;12:566-571.
|
11 |
Hamza TA, Ezzat HA, El-Hossary MM, Katamish HA, Shokry TE, Rosenstiel SF. Accuracy of ceramic restorations made with two CAD/CAM systems. J Prosthet Dent. 2013;109:83-87.
DOI
|
12 |
Foster LV. Failed conventional bridge work from general dental practice: clinical aspects and treatment needs of 142 cases. Br Dent J. 1990;168:199-201.
DOI
|
13 |
Ostlund LE. Cavity design and mathematics: their effect on gaps at the margins of cast restorations. Oper Dent. 1985;10:122-137.
|
14 |
Moldovan O, Rudolph H, Quaas S, Bornemann G, Luthardt RG. [Internal and external fit of CAM-made zirconia bridge frameworks - a pilot study]. Dtsch Zahnarztl Z. 2006;61:38-42. German.
|
15 |
McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131:107-111.
DOI
|
16 |
Kim DY, Kim JH. Comparison of shrinkage according to thickness of photopolymerization resin for 3D printing. J Tech Dent. 2021;43:1-5.
DOI
|