• 제목/요약/키워드: Dental CAD/CAM system

검색결과 156건 처리시간 0.03초

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

CAD/CAM 시스템으로 제작한 Milled Bar를 이용한 하악 임플란트 피개의치 수복증례 (Rehabilitation using mandibular implant overdenture with CAD/CAM milled bar: A case report)

  • 반민희;양홍서;박상원;임현필;윤귀덕;신진호;박찬
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.292-299
    • /
    • 2017
  • 무치악 환자에서 치아 상실 후 오랜 기간에 걸친 치조골 흡수는 의치의 사용을 어렵게 한다. 하악 무치악 환자에게 두 개 혹은 네 개의 임플란트를 식립하여 임플란트 피개의치를 이용하는 방식은 쉽게 접근할 수 있고, 의치의 유지, 지지와 안정을 크게 향상시킬 수 있는 방법이다. 임플란트 피개의치에 사용되는 어태치먼트 중에서 milled bar는 기성 bar보다 상부 구조물의 견고한 안정성과 충분한 유지력을 얻기 위해 사용할 수 있으며, 최근 CAD/CAM system의 발달과 함께 기공과정이 간소화되어 이용이 용이하게 되었다. 본 증례는 오랜 기간 상, 하악 총의치를 사용했던 환자에게 상악은 전통적인 방식으로 제작한 총의치와 하악에 네 개의 임플란트를 식립하여 CAD/CAM milled bar를 이용해 하악 임플란트 피개의치로 수복하여 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

치과용 3D 프린팅 기술로 제작된 가공물의 정밀성 분석 (Precision Analysis of Workpieces made with Dental 3D Printing Technology)

  • 최성민
    • 대한치과기공학회지
    • /
    • 제40권4호
    • /
    • pp.231-237
    • /
    • 2018
  • Purpose: The development of the dental technology industry has digitized the dental process. Definition of Digitalization of Dental Implantation Digitalization is the process of model making and prosthodontic processing using 3D CAD and CAM. Currently, it is becoming popular due to the spread of various devices. However, precision evaluation at this stage is an important factor in precision-based dental procedures. Therefore, in this study, we want to analyze the precision of the processed body made with digital dental machine. Methods: The accuracy of digital dental pore devices was evaluated. Specimens were fabricated with 5 types of 3D printers. The external shape was measured with the prepared specimen. The surface roughness was measured. Results: As a result, precision was excellent in order of EP2 specimen, EP1 specimen, and EA2 specimen. The precision of EP3 specimen and EA1 specimen is not excellent. And the precision of the specimen processed with polymer 3D printer is excellent. The accuracy of LCPS type polymer 3D printers is considered to be excellent. Conclusion : 1. Observation of the shape The 3D printer for LCPS system and the 3D printer for SLM $40{\mu}m$ system were found to be precisely processed. 2. Surface roughness results The LCPS system polymer 3D printer has been shown to have a precise surface.

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

  • Eun-Bin Bae;Won-Tak Cho;Do-Hyun Park;Su-Hyun Hwang;So-Hyoun Lee;Mi-Jung Yun;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.155-170
    • /
    • 2023
  • PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 ㎛ but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 ㎛ in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

Procera System의 역사적 고찰 (Procera System : a Review of Literature)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.309-315
    • /
    • 2006
  • Procera system으로 제작한 금관은 여러 연구들을 통해 강도, 적합도, 심미성, 시멘트 결합강도, 생체적합성 등에서 우수한 것으로 나타났고 오랜 기간 임상 연구를 통해서도 확인되었다. 따라서 주의 깊고 신중하게 임상에 적용시 만족스러운 보철물 제작이 가능할 것이다.

전치부 전부도재관을 이용한 테트라싸이클린 착색의 심미보철 회복 증례 (IPS e.max CAD 블록의 이용) (Esthetic Rehabilitation of Anterior Dentition by All Ceramic Crowns Using IPS e.max CAD : A Case of Tetracycline Discoloration)

  • 김재홍;조영규;김혜영
    • 치위생과학회지
    • /
    • 제11권4호
    • /
    • pp.299-303
    • /
    • 2011
  • The purpose of this case report was to present an example of an esthetic and functional rehabilitation of anterior teeth with tetracycline discoloration and minor morphological abnormality of a 39-year old female. A chairside computer-aided design/computer-aided manufacturing (CAD/CAM) system with CEREC AC was applied for the prosthetic procedure and all ceramic crowns made with lithum disilicate (IPS e.max CAD) restored the esthetic and functional features of sixteen anterior teeth successfully.

광간섭단층영상기를 이용한 치과용 지르코니아 코어의 적합도 분석 (Analysis of the Marginal and Internal Fit of Dental Zirconia Core Using Optical Coherence Tomography(OCT))

  • 김재홍;김기백
    • 한국콘텐츠학회논문지
    • /
    • 제12권8호
    • /
    • pp.240-247
    • /
    • 2012
  • 보철물이 구강 내 제 기능을 하기 위해 가장 중요한 요소 중 하나는 적합도이다. 본 연구의 목적은 그 동안 시도되지 않았던 광간섭단층영상기를 이용하여 비파괴적인 방법으로 적합도를 측정해보고, 측정된 값을 기존의 방법으로 측정된 값과 비교하여 보고자 한다. 실험을 위해 상악 우측 중절치가 지대치인 석고모형 10개를 제작하고 치과용 캐드캠으로 각각의 모형에 해당하는 지르코니아 코어를 10개 제작하였다. 시편 당 5부위 씩 광간섭단층영상기로 적합도를 측정하고, 같은 부위를 기존의 방법인 실리 복제본 기술로 측정하였다. 두 집단 간의 평균 값에 유의한 차이가 있는지 알아보기 위해 독립표본 t-검정을 실시하였다(${\alpha}$=0.05). 그 결과 측정된 두 집단 간의 평균 값에는 유의한 차이를 보이지 않았고(P>0.05), 이러한 결과로 미루어 볼 때 앞으로 광간섭단층영상기를 이용한 보철물의 적합도 측정이 가능할 것으로 사료된다.