DOI QR코드

DOI QR Code

Rehabilitation using mandibular implant overdenture with CAD/CAM milled bar: A case report

CAD/CAM 시스템으로 제작한 Milled Bar를 이용한 하악 임플란트 피개의치 수복증례

  • Ban, Min-Hee (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Yang, Hongso (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Park, Sang-Won (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Lim, Hyun-Pil (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Yun, Kwi-Dug (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Shin, Jin-Ho (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Park, Chan (Department of Prosthodontics, School of Dentistry, Chonnam National University)
  • 반민희 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 양홍서 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 박상원 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 임현필 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 윤귀덕 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 신진호 (전남대학교 치의학전문대학원 치과보철학교실) ;
  • 박찬 (전남대학교 치의학전문대학원 치과보철학교실)
  • Received : 2017.01.04
  • Accepted : 2017.03.24
  • Published : 2017.07.31

Abstract

Long-term alveolar bone resorption in edentulous patient causes difficulty in denture use. Applying an implant overdenture with 2 to 4 implants to edentulous patient is easily approachable. Moreover, it improves denture stability, support, and retention. Milled bar, the attachment used in implant overdenture, can be used to induce better stability and retention to the supporting structure than conventional bar. It has become convenient to use due to the development of CAD/CAM system which had allowed the simplification of dental techniques. In this case, application of conventional maxillary full denture and mandibular overdenture made of CAD/CAM milled bar with 4 implants showed satisfactory results in the patient who had used upper and lower full dentures for a long time.

무치악 환자에서 치아 상실 후 오랜 기간에 걸친 치조골 흡수는 의치의 사용을 어렵게 한다. 하악 무치악 환자에게 두 개 혹은 네 개의 임플란트를 식립하여 임플란트 피개의치를 이용하는 방식은 쉽게 접근할 수 있고, 의치의 유지, 지지와 안정을 크게 향상시킬 수 있는 방법이다. 임플란트 피개의치에 사용되는 어태치먼트 중에서 milled bar는 기성 bar보다 상부 구조물의 견고한 안정성과 충분한 유지력을 얻기 위해 사용할 수 있으며, 최근 CAD/CAM system의 발달과 함께 기공과정이 간소화되어 이용이 용이하게 되었다. 본 증례는 오랜 기간 상, 하악 총의치를 사용했던 환자에게 상악은 전통적인 방식으로 제작한 총의치와 하악에 네 개의 임플란트를 식립하여 CAD/CAM milled bar를 이용해 하악 임플란트 피개의치로 수복하여 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

Keywords

References

  1. Cordioli G, Majzoub Z, Castagna S. Mandibular overdentures anchored to single implants: a five-year prospective study. J Prosthet Dent 1997;78:159-65. https://doi.org/10.1016/S0022-3913(97)70120-3
  2. Jemt T, Chai J, Harnett J, Heath MR, Hutton JE, Johns RB, McKenna S, McNamara DC, van Steenberghe D, Taylor R, Watson RM, Herrmann I. A 5-year prospective multicenter follow-up re-port on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants 1996;11:291-8.
  3. Shayan N, Ashish C, Mohamad I, Muzafar A. Implant supported overdenture: an alternative to conventional denture- a case report. J Dent Med Sci 2016;15:39-42.
  4. Stoumpis C, Kohal RJ. To splint or not to splint oral implants in the implant-supported overdenture therapy? A systematic literature review. J Oral Rehabil 2011;38:857-69. https://doi.org/10.1111/j.1365-2842.2011.02220.x
  5. Sadowsky SJ. Mandibular implant-retained overdentures: a literature review. J Prosthet Dent 2001;86:468-73. https://doi.org/10.1067/mpr.2001.119921
  6. Burns DR. Mandibular implant overdenture treatment: consensus and controversy. J Prosthodont 2000;9:37-46. https://doi.org/10.1111/j.1532-849X.2000.00037.x
  7. Krennmair G, Krainhofner M, Piehslinger E. Implant-supported mandibular overdentures retained with a milled bar: a retrospective study. Int J Oral Maxillofac Implants 2007;22:987-94.
  8. Bakke M, Holm B, Gotfredsen K. Masticatory function and patient satisfaction with implant-supported mandibular overdentures: a prospective 5-year study. Int J Prosthodont 2002;15:575-81.
  9. Berretin-Felix G, Nary Filho H, Padovani CR, Trindade Junior AS, Machado WM. Electromyographic evaluation of mastication and swallowing in elderly individuals with mandibular fixed implant-supported prostheses. J Appl Oral Sci 2008;16:116-21. https://doi.org/10.1590/S1678-77572008000200007
  10. Carlsson GE, Lindquist LW. Ten-year longitudinal study of masticatory function in edentulous patients treated with fixed complete dentures on osseointegrated implants. Int J Prosthodont 1994;7:448-53.
  11. Spyropoulou PE, Razzoog ME, Duff RE, Chronaios D, Saglik B, Tarrazzi DE. Maxillary implant-supported bar overdenture and mandibular implant-retained fixed denture using CAD/CAM technology and 3-D design software: a clinical report. J Prosthet Dent 2011;105:356-62. https://doi.org/10.1016/S0022-3913(11)60071-1
  12. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008;204:505-11. https://doi.org/10.1038/sj.bdj.2008.350
  13. Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 2007;28:4845-69. https://doi.org/10.1016/j.biomaterials.2007.07.013
  14. Toth JM, Wang M, Estes BT, Scifert JL, Seim HB 3rd, Turner AS. Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 2006;27:324-34. https://doi.org/10.1016/j.biomaterials.2005.07.011
  15. Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR. Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 2013;101:1209-16. https://doi.org/10.1002/jbm.b.32932
  16. Liebermann A, Wimmer T, Schmidlin PR, Scherer H, Loffler P, Roos M, Stawarczyk B. Physicomechanical characterization of polyetheretherketone and current esthetic dental CAD/CAM polymers after aging in different storage media. J Prosthet Dent 2016;115:321-8. https://doi.org/10.1016/j.prosdent.2015.09.004