• 제목/요약/키워드: Dental Bridge

검색결과 197건 처리시간 0.023초

미국 보철분야학회를 돌아보고

  • 장익태
    • 대한치과의사협회지
    • /
    • 제22권5호통권180호
    • /
    • pp.397-403
    • /
    • 1984
  • 본인은 미국 시카코에서 개최되었던 미국치과보철학회(2월17일~2월18일), 미국 Crown and Bridge학회(2월18일~2월19일), 미국 Equilibration학회(2월15일~2월16일) 및 Chicago Midwinter meeting(2월19일~2월22일)에 참석하고 보철학 분야의 미국 및 세계적 추세와 임상분야의 경향에 관하여 참관기를 기술하고져 한다.

  • PDF

치과기공사의 업무실태에 따른 생산성 분석 연구 (An Analysis of Productivity according to the Actual Conditions of Dental Laboratory Technician)

  • 차성주
    • 대한치과기공학회지
    • /
    • 제9권1호
    • /
    • pp.5-19
    • /
    • 1987
  • The factors which impact on the productivity of medical organization are technique, manager, raw materials, management style, manpower structure, job construction, and so on. Human resources is the most important factor among them, but the productivity of serice organization can not be measured easily. The purpose of this study was to verify the effect of laboratory status, the degree of job cognition, and stress on the productivity of dantal prosthetic products, and to fine out the factors which impact on the productivity. The results were as follows: 1. The job characteristice of crown bridge laboratory part and porcelain laboratory part similar to each other. Also partial denture laboratory part and complete denture laboratory part were similar to each other. But that of orthodontic laboratory part was different from other. 2. the degree of job cognition made significant difference statisfically according to job characteristics of each dental laboratorise. 3. The correlation coefficient between job cognition of dental laboratory technician and workshop environment was.23, but the correlation between job cognition job stress appeared reversely, its coefficient was-.17. 4. The productivity of technician engaged in dental laboratory was much heigher than that of technician engaged in dental clinical laboratory room, and each were different in the degree of job cognition. 5. the most important factors which impact one the performance productivity of dental laboratory technician were the fact whether he married or not and his status.

  • PDF

임플란트 환자의 분포 및 식립부 유형 (The Distribution of Implant Patients and the Type of Implant Site)

  • 박지은;윤정호;정의원;김창성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제34권4호
    • /
    • pp.819-836
    • /
    • 2004
  • Nowdays, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The reason is that unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. So, It is needed understanding about the type, distribution of implant patient. The following results on patient type and implant distribution were compiled from 4433 implant cases of 1596 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2004. 1. There are no dissimilarities between men and women, with patients in their 40, 50s accounting for 52.5% of patients and 57.5% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 54.9% of implant treatments followed by Mx. posterior area(27.6%), Mx anterior area(11.9%) and Mn anterior area(5.6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 97.5% and fully edentulous patient accounted for the remaining 2.5%. 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. In the distribution of bone quality for maxillae, type III was most, followed by type II, r type IV and r type I. As for mandible, type II was most, followed by type III, type IV and for type I. 6. In the distribution of bone quantity for maxillae, type C was most, followed by type B, type D, type A, and for type E. As for mandible, type B was 52% most, followed by type C, type D, type A and type E. 7. The majority of implants were those of 1O-14mm in length (85.2%) and regular diameter in width (64%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

치기공과 교육과정의 개선 방안 - 재학생을 중심으로 - (Departments of Dental Technology An improvement plan of Curriculum - Focus on students who being in college -)

  • 배봉진;이화식;박명호
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.49-64
    • /
    • 2007
  • This research collected the curriculum for Dental Technology from a total of 20 schools -3-year colleges and 4-year colleges- all in Korea. And we analyzed the average credits of subjects from students. As a result of this analysis, we get the conclusion below: 1. In a distribution which students answered about each subjects; Seminar, Dental morphology I II, Dental morphology practice I II, and Dental devices & instruments don't have many credits and mostly have a converged tendency in high points, according to the arithmetic mean of the major basis subjects. 2. In an analysis of the correlation which is based on the distinction of sex: Complete denture prosthodontics I II III, Dental orthodontics I II, Dental orthodontics practice I II, and Dental orthodontics & practice III have a meaningful difference. ($\rho$< 0.05 ) 3. In an analysis of the correlation which is based on an age The major basis subjects -Introduction to dental technology, Dental esthetic, and Dental casting procedure-, and the major application subjects -Crown and bridge prosthodontics practice, Complete denture prosthodontics, Dental orthodontics, Dental orthodontics practice, and Operative dentistry laboratory technology- have meaningful difference. ($\rho$< 0.05 ) 4. In a correlation coefficient between subjects; The correlation coefficient of the major application subjects is higher than the major basis subjects. According to the student - t, we found that the level of significance is $\rho$< 0.001, which is meaningful. We feel the lack of a limitation which we didn't survey all students who are major in Department of Dental Technology. And we also feel that we'd better to consider not only students who being in college but also graduated students.

  • PDF

임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용 (Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner)

  • 박지만;박은진;허성주
    • 대한치과의사협회지
    • /
    • 제52권6호
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

치기공과 교육과정 제고를 위한 치과기공사의 직업기초능력 중요도 분석 (Analysis on the Importance of Dental Technicians' Basic Vocational Competency elements to Improve the Dental Technology Curriculum)

  • 정효경;박남규
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.31-41
    • /
    • 2019
  • Purpose: This provides basic data for improving educational effectiveness by selecting and applying basic vocational competency applicable to dental technology's sub-major curricula by determining and researching dental technicians' awareness levels concerning the basic vocational competency's importance. Methods: 170 dental technicians working in Daegu, Korea were surveyed using a self-administered questionnaire between 9 January 2018 and 23 February 2018. Results: 1. The highest level of the basic vocational competency elements by the awareness levels of importance in dental technology laboratories was shown in the occupational ethics, followed by technological skills, interpersonal skills, self-development levels, problem-solving skills, information skills, resource management skills and skills for understanding groups, communication skills, and mathematical skills. 2. Female dental technicians put relatively higher importance on writing documents and managing time, while males stressing on basic statistics. 3. Dental laboratory CEOs and managers put high values on resource management skills, while head technicians valuing information skills more. 4. The awareness levels concerning the basic vocational competency importance in some dental technology fields did not match those of the dental technology laboratories in the fields of porcelain, crown and bridge, and orthodontics. Conclusion : This study demonstrates that the awareness levels concerning basic vocational competency's importance in some fields of dental technology differ from those of dental technology laboratories. Developing a basic vocational competency curriculum, it seems necessary to find ways to increase educational effectiveness by selecting and applying the basic vocational competency for the respective fields of dental technology.

Vent의 형성이 도재전장 비귀금속합금 주조체의 변연부 적합도에 미치는 영향 (The effect of vent on the marginal discrepancy of the PFM base metal castings)

  • 김태석;이성욱;오세윤;김웅철;김지환;유진호
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.45-53
    • /
    • 2001
  • This study was performed to investigate the effect of vent on the marginal discrepancy of PFM base metal castings. Eighteen identical wax patterns of a maxillary 3 unit anterior bridge were fabricated. Nine cases out of them were vented with $\phi$2.5mm sprue wax, for direct comparison as to the marginal discrepancy of the castings with the other non vented 9 ones. The mean value of marginal discrepancies of the vented castings was $85.02{\pm}25.57{\mu}m$, and that of the non vented was $163.21{\pm}69.88{\mu}m$ respectively. Statistical analysis revealed that marginal discrepancy of the vented casting was significantly reduced(p<0.05).

  • PDF

ITI - Octa system을 이용한 fixed removable bridge의 제작

  • 이성욱;안재석;이정환;이용원
    • 대한치과기공학회지
    • /
    • 제24권1호
    • /
    • pp.139-143
    • /
    • 2002
  • 일반적으로 악골의 흡수가 심한 환자에게 총의치 보철물은 적은 유지력 때문에 매우 불리하다. 특히, 하악골의 흡수가 심한 환자의 경우 2$\sim$4 정도의 임플란트를 식립후에 제작되는 stud type의 over-denture나 bar-over denture 또는 magnetic over-denture 등이 있고, 5$\sim$6개 정도의 임플란트 식립으로 제작되는 fixed removable bridge가 환자에게 높은 만족감을 줄 수 있어 총의치 보철 치료시 고려해야 할 보철 치료 방법중의 하나이다. fixed removable bridge를 제작하는데 있어 먼저 placement guide를 이용하여 모델의 임플란트의 위치와 구강내의 임플란트의 위치를 반드시 확인해야 하고, 구조물을 만들기 전에 wax denture를 제작하여 환자의 simile line 이나 악간 관계를 확인 후에 구조물 제작을 해야 한다.

  • PDF

치과기공사국가시험 문항개발기준안연구 (Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician)

  • 이덕혜;정인성;한창식
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향 (Effect of abutment superimposition process of dental model scanner on final virtual model)

  • 유범영;손큰바다;이규복
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.203-210
    • /
    • 2019
  • 목적: 본 연구는 치과용 모형 스캐너를 이용하여 단일 전장관과 3본 고정성의치 모형을 스캔하는 과정에서 지대치의 중첩 과정이 최종 가상 모형에 미치는 영향을 알아보려 하였다. 재료 및 방법: 평가를 위해 단일 전장관과 3본 고정성의치를 위한 석고 모형을 제작하였다. 그리고 Pindex system을 이용하여 핀 작업된 모형을 제작하였다. 기준 스캔 데이터(CAD Reference Model)와 실험 스캔 데이터(CAD Test Model)를 획득하기 위해서 치과용 모형 스캐너(E1, 3Shape A/S, Copenhagen, Denmark)를 이용했다. 기준 스캔 데이터는 지대치를 분할한 후 탈착하지 않고 스캔하였다. 그리고 실험 스캔 데이터는 분할된 지대치를 분리하여 스캔 후, 기준 스캔 데이터에 중첩되었다(n = 20). 마지막으로 3차원 검사 소프트웨어(release 2018.0.0; Geomagic control X; 3D Systems)를 이용하여 root mean square (RMS)를 분석하였고, 통계 분석은 Mann-Whitney U test를 사용하였다 (${\alpha}=.05$). 결과: 단일 전장관 지대치의 RMS 평균은 $10.93{\mu}m$, 3본 고정성의치 지대치의 RMS 평균은 $6.9{\mu}m$가 나왔다. 두 그룹의 RMS 평균값은 통계적으로 유의한 차이를 보여줬다 (P < .001). 또한 두 그룹의 양(positive)과 음(negative)의 오류는 단일 전장관 지대치는 $9.83{\mu}m$, $-6.79{\mu}m$, 3본 고정성의치 지대치는 $6.22{\mu}m$, $-3.3{\mu}m$의 평균값이 나왔다. 두 그룹의 양과 음의 오류 평균값은 통계적으로 모두 3본 고정성의치 지대치가 단일 전장관 지대치보다 통계적으로 유의하게 낮은 값을 보여주었다 (P < .001). 결론: 핀 작업된 모형의 스캔 과정에서 지대치의 개수가 증가하여도 지대치의 중첩에 의한 오류는 증가하지 않았다. 또한 단일 전장관 지대치에서 유의하게 높은 오류를 보였지만 임상적으로 허용 가능한 스캔 정확도의 범위에 있다.