• Title/Summary/Keyword: Density current

Search Result 5,689, Processing Time 0.032 seconds

The Stress Dependence of Trap Density in Silicon Oxide

  • Kang, C. S.
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.2
    • /
    • pp.17-24
    • /
    • 2000
  • In this paper, the stress and transient currents associated with the on and off time of applied voltage were used to measure the density and distribution of high voltage stress induced traps in thin silicon oxide films. The transient currents were due to the discharging of traps generated by high stress voltage in the silicon oxides. The trap distributions were relatively uniform new both cathode and anode interface. The trap densities were dependent on the stress polarity. The stress generated trap distributions were relatively uniform the order of 1011~1021[states/eV/cm2] after a stress voltage. It appear that the stress and transient current that flowed when the stress voltage were applied to the oxide was caused by carriers tunneling through the silicon oxide by the high voltage stress generated traps.

  • PDF

Study on the Crevice Corrosion Behavior of SS 400 in Marine Environment (해양환경중에서 SS400강재의 간극부식거동에 관한 연구)

  • 임우조;정기철;안석환;윤병두
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.1-6
    • /
    • 2000
  • This paper was studied on the crevice corrosion behavior of SS 400 in marine environment. In 0%, 2%, 3.5%, 5% NaCl solution, the aspect of the crevice corrosion and polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 with crevice and non-crevice was measured according to the NaCl concentration. The main results obtained are as follows : 1) Under crevice corrosion, the corrosion potential become less noble as the concentration of NaCl solution increased. 2) The current density under open circuit potential was high drained as concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, the current density was low drained. 3) The weight loss rate of SS400 was increased as concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of SS400 was decreased.

  • PDF

A study on the improvements of Critical Current Density of Bi2223 Superconducting Tapes in PIT process (PIT법에 의한 Bi-2223 고온 초전도 테이프의 임계전류밀도 향상에 관한 연구)

  • 장현만;오상수;하동우;류강식;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.198-201
    • /
    • 1996
  • In order to investigate control factors to critical current density, Ag sheathed Bi2223 superconducting tapes were fabricated using PIT process. Optimizing the reduction ratio of rolling, critical current density 7f rolled Bi2223 tape could be improved with the value of 15,000 A/$\textrm{cm}^2$(77 K, zero field). The correlation between J$\_$c/ and work inhomogeneity was revealed as a dependence of COV of measured oxide layer thickness.

  • PDF

Analysis of the Electromagnetic Phenomena in Vacuum Interrupter with Axial Magnetic Field Type (축자계형 진공인터럽터의 전자계 현상 해석)

  • 하성철;서상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.952-957
    • /
    • 2003
  • The purpose of this paper is analyses about in 12kV/50kA vacuum interrupter with an axial magnetic field type electrode system through the studies of electromagnetic phenomena. Vacuum interrupter is important in electric safety part. In this paper, we performed analysis of electric field, magnetic field, current density in AMF electrode using the Maxwell 3D simulation. The current distribution and magnetic field in simple models are analyzed to verify its efficiency and accuracy. In addition the validity of FEM is confirmed by performing the analyses of distribution in current density and magnetic flux density.

Enhanced Corrosion Resistance of WC-Co with an Ion Beam Mixed Silicon Carbide Coating

  • Yeo, Sun-Mok;Park, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.193-193
    • /
    • 2011
  • Strong adhesion of a silicon carbide (SiC) coating to a WC-Co substrate was achieved through an ion beam mixing technique and the corrosion resistance of the SiC coated WC-Co was investigated by means of a potentiodynamic electrochemical test. In a 1 M NaOH solution, the corrosion current density of SiC-coated WC-Co after heat treatment at 500$^{\circ}C$ was about 50 times lower than that for the as-received WC-Co. In addition, the corrosion resistance systematically increases with increasing the SiC coating thickness. On the other hand, for a 0.5 M H2SO4 solution, the corrosion current density for SiC-coated WC-Co was about 3 times lower than that for the as-received WC-Co. We discuss the physical reasons for the changes in the corrosion current density with the different electrolytes.

  • PDF

Electrolysis for NiW Functional Alloy Plating (NiW 기능성 합금도금을 위한 전해)

  • Jeong, Goo-Jin;Lee, Churl-Kyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • A NiW functional alloy plating was investigated as variables of metal ion concentration, complexing agent, temperature, pH and applied current density. Even if numerous studies on reaction mechanism of NiW induced codeposition were carried out during couples of decade, it has not been acceptable reaction mechanism. This study was focused on the effect of the plating variables on the alloy composition in the NiW alloy plating. Applied current density could control mainly the alloy composition rather than other plating variables. It has also been confirmed that the functional alloy plating such as layered or gradient plating was possible by controlling applied current density.

Fabrication Technology of high Tc Superconductor for Electrical Equipment (전력기기 초전도 합성기술)

  • Lee, Sang-Heon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.7
    • /
    • pp.364-366
    • /
    • 2006
  • In order to realize the commercial application of HTSC materials, it is necessary to develop the fabrication process of high Tc oxide superconductor materials with desired shape and for practical application and high critical current density as well as good mechanical strength which can withstand high lorenz force generated at high magnetic field. Much studies have been concentrated to develop the fabrication technique for high critical current density but still there are a lot of gap which should be overcome for large scale application of HTSC materials at liquid nitrogen temperature. Recently some new fabrication techniques have been developed for YBaCuO bulk superconductor with high mechanical strength and critical current density. In this project, the establishment of fabrication condition and additive effects of second elements were examined so as to improve the related properties to the practical use of YBaCuO superconductor, and we reported the production of the YBaCuO high Tc superconductor by the pyrolysis method.

An Analysis on the Performance and the Heat Transfer of Molten Carbonate Fuel Cell Stack (용융탄산염 연료 전지 스택의 성능 및 열전달 해석)

  • Koo, J.Y.;Suh, J.C.;Kim, Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.120-129
    • /
    • 1994
  • A numerical investigation has been carried out for the electrochemical reaction, mass and heat transfer characteristics of the Molten Carbonate Fuel Cell(MCFC) stack. The effects of cooling air channel and water gas shift reaction were taken into account. The current density distribution of electrodes, the molecular fractions of reactant gasses and three dimensional temperature distribution can be calculated and shown by several lines of equivalent values. The results have been compared with the existing ones, and reasonable agreement has been obtained. To examine the influence of changing parameters, such as the composition of reactant gases, the target average current density, the utilization of reactant gases, the cooling air inlet temperature and flow rates, the computer simulation has been done. The analysis method and computer program developed in this study will be greatly helpful to design and verify the optimum operating condition of MCFC stack.

  • PDF

Study on the Recoil Operation of the Servomotor with PM Poles (PM형 제어용 Servo전동기의 Recoil동작에 관한 연구)

  • Se Hoon Chang
    • 전기의세계
    • /
    • v.21 no.4
    • /
    • pp.15-21
    • /
    • 1972
  • For the conventional DC machine, the armature MMF is negligible compared with field MMF except when the machine is under heavy load or transient conditions. During the motor starting or reversal, the transient armature current and corresponding MMF effect the flux density of each pole in the machine magnetic circuit. However, the circuit flux density is restored to normal values by the field winding MMF after the transient armature current dies in an electromagnetic DC motor. Permanent magnet servomotor have no field windings about the circuit poles to restore circuit flux density through the demagnetized part of each pole after the transient armature MMF dies, and portions of the magnetic circuit stay permanently demagnetized. Thus the problem of stabilizing a magnet pole piece under the influence of the transient armature current need attentions. This work present the recoil operation of the servomotor with PM poles in conjunctions with the influence of the armature reaction effect. The development of an analytical and quantatative study is presented for predicting the regime of the recoil operation under this condition.

  • PDF

The effect of cryogenic rolling on critical current density of Bi-2223/Ag HTS tapes (Bi-2223/Ag 고온초전도선재의 Jc와 미세조직에 미는 저온압연의 영향)

  • 최정규;황선역;하동우;오상수;권영길;이세종
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.142-145
    • /
    • 2003
  • In order to investigate the effect of cryogenic rolling on the critical current density (Jc), 54 and 55-multi-filament Bi-2223/hg tapes have been fabricated using a PIT process including two different types of cooling methods. The densification of oxide filament was found to occur due to the cryogenic rolling, and this enhanced the critical current density. However, when the wire was fully immersed in liquid nitrogen used as the coolant in cryogenic rolling, Jc degradation appeared caused by the nitrogen penetration into the filament. The cryogenically rolled tape with an improved type of cooling showed approximately 10% Jc's increase.

  • PDF