• Title/Summary/Keyword: Delta power

Search Result 753, Processing Time 0.027 seconds

A Study on the Delta-Connected Cycloconverter by Phase-Controlled Rectifier (위상제어 정류기에 의한 ${\Delta}$-접속형 싸이크로 컨버어터에 관한 연구)

  • Chung, Y.T.;Seo, Y.S.;Lee, S.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.456-458
    • /
    • 1991
  • Beacause cycloconverter requires AC power converter each phase, it has the disadvantage of complexity in main system. In this paper, the simple circulating current typed cycloconverter obtained the three variable voltage and variable frequency by delta-connceting the three natual commuatation phase controled rectifiers is constructed.

  • PDF

Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters (인버터 구동형 저압 유동전동기의 절연특성 분석)

  • 박도영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

Comparison of Nondestructive and Destructive Tests in High Voltage Motor Stator Windings (고압전동기 고정자 권선에서 비파괴와 파괴시험의 비교)

  • Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2097-2100
    • /
    • 1999
  • Nondestructive and destructive tests were performed the stator windings of three high voltage motors prior to the rewind. Nondestructive tests included ac current increase rate($\Delta$I), dissipation factor(${\Delta}tan{\delta}$), and maximum partial discharge(Qm) The destructive tests included breakdown at three phases with ac voltage. Flashover occurred between the connected winding of endwinding and the stator flame. In two cases creeping discharge occurred between the individual phase windings and the wedges In the stator ends. The results of destructive tests could rarely be determined the breakdown voltage.

  • PDF

A CMOS Band-Pass Delta Sigma Modulator and Power Amplifier for Class-S Amplifier Applications (S급 전력 증폭기 응용을 위한 CMOS 대역 통과델타 시그마 변조기 및 전력증폭기)

  • Lee, Yong-Hwan;Kim, Min-Woo;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • A CMOS band-pass delta-sigma modulator(BPDSM) and cascode class-E power amplifier have been developed CMOS for Class-S power amplifier applications. The BPDSM is operating at 1-GHz sampling frequency, which converts a 250-MHz sinusoidal signal to a pulse-width modulated digital signal without the quantization noise. The BPDSM shows a 25-dB SQNR(Signal to Quantization Noise Ratio) and consumes a power of 24 mW at an 1.2-V supply voltage. The class-E power amplifier exhibits an 18.1 dBm of the maximum output power with a 25% drain efficiency at a 3.3-V supply voltage. The BPDSM and class-E PA were fabricated in the Dongbu's 110-nm CMOS process.

A Study on Dielectric Properties of XLPE for High Voltage (고압용 XLPE의 유전특성에 관한 연구)

  • Lee, Yong-Sung;Lee, Kyung-Yong;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1561-1563
    • /
    • 2004
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. We studied effects for impurities and water for semiconductor shield through a dielectric properties experiment to estimate performance of insulating materials in power cable. Capacitance and tan${\delta}$ of 22[kV], 154[kV] were 53/43[pF] and $7.4{\times}10^{-4},\;2.1510^{-4}$. In these results, the trend was increased with the increase of temperature. The tan${\delta}$ of XLPF/ semiconductor layer was increased as compared with that of XLPE. Dielectric properties reliability of tan${\delta}$ was small.

  • PDF

Phase Equilibria of the Ferrous Ferrite System of $(Mg_{0.29}-yMnyFe_{0.71})_{3-}\delta$O_4$ ($(Mg_{0.29}-yMnyFe_{0.71})_{3-}\delta$O_4$ 훼라이트계의 상평형)

  • 채정훈;유한일;강선호;강대석;유병두
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.3
    • /
    • pp.394-402
    • /
    • 1995
  • Electrical conductivity and thermoelectric power of the ferrous ferrite system of (Mg0.29-yMnyFe0.71)3-$\delta$O4 have been measured as function of the thermodynamic variables, cationic composition(y), temperature(T) and oxygen partial pressure(Po2) under thermodynamic equilibrium conditions at elevated temperatures. On the basis of the electrical properties-phase stability correlation, the stability regions of the ferrite spinel and its neighboring phases have been subsequently located in the log Po2 vs. y and log Po2 vs. 1/T planes in the ranges of 0 y 0.29, 1100 T/$^{\circ}C$ 1400 and 10-14 Po2/atm 1. The stability region, Δlog Po2(y, 1/T), of the ferrite spinel single phase widens with increasing Mn-content(y) and the boundaries of each region are linear against 1/T with negative slopes.

  • PDF

Dielectric Properties of XLPE/Semiconductor Sheet in Power Cables (전력케이블용 XLPE/반도전층의 유전 특성)

  • 이관우;이경용;최용성;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.8
    • /
    • pp.904-909
    • /
    • 2004
  • We studied the dielectric properties and voltage dependence on slice XLPE sheet from 22 kV and 154 kV power cables. Interface structures are XLPE/semiconductor and XLPE/water/semiconductor capacitance and tan6 of 22 kV, 154 kV were 52/42 pF and $7.4\times{10}/^{-4}, 2.15\times{10}^{-4}$, respectively in these results, the trend was increased with the increase of temperature the tan$\delta$ of XLPE/semiconductive layer and XLPE/water/ semiconductive layer were increased as compared with that of XLPE Temperature reliability of tan$\delta$ was small.

Understanding CT Connection through 3rd Bus Connection of the 345kV Auto Transformer (345kV 변압기 3차 모선결선을 통한 보호용 변류기 결선의 이해)

  • Yoon, Jung-duck;Kim, Jae-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.439-440
    • /
    • 2015
  • 한전의 전력계통망에 사용중인 345kV 변압기는 1차와 2차 권선의 일부회로를 공통으로 사용하는 단상 단권변압기를 사용하고 있다. 단상변압기로 인한 3차결선은 변압기 외부에서 알루미늄 부스바를 이용하여 모선을 구성한다. 한편, ${\Delta}$결선의 특징은 3차측 붓싱의 극성과 관련하여 결선방식에따라 3차측 위상이 1차측 위상보다 $30^{\circ}$진상 또는 지상의 위상특성을 가지고 있어 비율차동계전기 결선방식에 있어 주의를 요한다. 변압기는 YNautod1결선 또는 YNautod11으로 결선할 수 있다. 한편 비율차동기용 결선은 1차측과 2차측은 ${\Delta}$결선으로 3차측은 Y결선으로 비율차동계전기에 입력이 되어야 한다. 이때 3차측의 위상을 고려하여 1차측과 2차측의 CT ${\Delta}$결선은 변압기 결선방식과 동일한 결선으로 시행하여 한다.

  • PDF

Degradation and Dielectric Properties of 22/154kV XLPE sheets (22/154kV급 XLPE의 유전특성과 절연열화)

  • Lee, Kwan-Woo;Lee, Jong-Bok;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.84-87
    • /
    • 2001
  • In this paper, degradation and dielectric properties of XLPE sheets moved from 22/154kV power cables were investigated. At the results of dielectric property of 22kV/154kV XLPE sheet, We earned that $tan{\delta}$ is $7.4{\times}10^{-4}$, $2.15{\times}10^{-4}$ and dielectric constant is 2.3, 2.24. Temperature dependance of $tan{\delta}$ inclined to increasing with temperature and increase of $tan{\delta}$ of 22kV XLPE sheet is higher than it of 154kV XLPE sheet. And increasement of XLPE sheet with water is higher than it without water.

  • PDF

Current Compensation Scheme to Reduce Torque Ripples of Delta-connected Low-inductance BLDC Motor Drives (델타 결선형 저인덕턴스 BLDC 전동기의 토크 리플 저감을 위한 전류 보상 기법)

  • Park, Do-Hyeon;Lee, Dong-Choon;Lee, Hyong-Gun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.449-456
    • /
    • 2017
  • This study proposes a method for compensating for the commutation torque ripple of delta-connected brushless DC motors with low inductance based on a current predictions. At the commutation instant, a phase current at the next sampling period is predicted and compared with the reference phase current to determine whether torque ripples will occur or not. If the predicted current cannot reach the reference phase current, the reference current is modified and the relevant voltage reference is produced to reduce the torque ripple. The validity of the proposed method has been verified by simulation and experimental results. The commutation torque ripple has been decreased by 17.7% at 1,000 rpm and 80% load conditions.