• 제목/요약/키워드: Delta Modulation

검색결과 152건 처리시간 0.02초

Double delta Modulation에 관한 연구 (A study on the Double Delta Modulation System)

  • 이종각;강상철
    • 대한전자공학회논문지
    • /
    • 제13권6호
    • /
    • pp.24-29
    • /
    • 1976
  • A study is presented on the DDM (double delta modulation) system which incorporates another modulation loop in front of the delta modulation system. DDM is proposed to delta modulate the error signal which is derivated through the ordinary delta modulation. This system is constructed simply by adding a differential amplifier and an integrator to the basic DM system. Since signal-to-quantization noise ratio SNR is the most informative measure of quantizer performance, the formula of the max. SNR of the DDM system is derived and investigated experimentally for a sinusoidal input. The max. SNR of the DDM is larger than that of DM in low bit rate region and vice versa in high bit rate region.

  • PDF

2차 Space Dithered Sigma-Delta Modulation 기반의 Random PWM 스위칭 기법을 이용한 강압형 DC-DC 컨버터의 성능 개선 (Performance Improvement of a Buck Converter using a End-order Space Dithered Sigma-Delta Modulation based Random PWM Switching Scheme)

  • 김서형;주성탁;정해광;이교범;정규범
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2009
  • 본 논문에서는 강압형 DC-DC 컨버터의 성능 개선을 위한 스위칭 기법인 2차 SDSDM (Space Dithered Sigma Delta Modulation)방식을 제안한다. PWM (Pulse Width Modulation) 방식은 일정 스위칭 주파수 대역에서의 고조파로 인해 소음, 전자파 장애, 스위칭 손실 등을 유발한다. 이러한 문제를 해결하기 위한 DSDM 방식의 일종인 1차 SDSDM은 랜덤 디더(Random Dither) 발생기가 1차 SDM의 양자화기(quatizer) 입력단에 위치하여 스위칭 주파수가 분산된다. 강압형 DC/DC 컨버터에 제안하는 2차 SDSDM의 방식을 적용한 실험 결과를 통해 타당성을 검증한다.

Improved Switching Frequency in Delta Modulated Inverter for UPS Applications

  • Sodaban, C.;Tipsuwanporn, V.;Thepsatorn, P.;Piyarat, W.;Witheephanich, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.986-989
    • /
    • 2004
  • The concept and results of a simple constant switching frequency delta modulation scheme suitable for DC-AC power conversion in uninterruptable power supply (UPS) applications are presented. Unlike the traditional delta modulation scheme, the scheme has a well defined harmonic spectrum, resulting in a simple filter design and reduced radio interference.

  • PDF

Elimination of Idle Tones by a 2-Bit Adaptive Sigma-Delta Modulation System

  • Prosalentis, Evangelos;Tombras, George S.
    • ETRI Journal
    • /
    • 제31권4호
    • /
    • pp.393-398
    • /
    • 2009
  • The operation of a first-order 2-bit adaptive sigma-delta modulation system is described and discussed in this paper. The system operation is based on the combination of both "memory" and "look-ahead" estimation in the employed step-size adaptation algorithm of the basic quantizer. In comparison to simple systems and other adaptive sigma-delta systems, computer simulation results show that these features of the described system are responsible for the high SNR values and the extended dynamic range achieved for AC signals as well as the noise power reduction of almost 10 dB and the complete elimination of the idle tones for DC signals. However, such an advantageous performance requires the least possible multiplicative error accumulation, and this cannot be achieved without analog circuits of the highest possible accuracy.

EPLD 로직구현을 통한 델타변조기법에 의한 스위치드 리럭턴스 전동기의 전류제어 (Current Control of Switched Reluctance Motor with Delta Modulation Method on EPLD Logic Design)

  • 윤용호;김재문
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.356-361
    • /
    • 2008
  • The conventional drive system of SRM has a current sensor per each phase. The torque demand signal generated by the outer control loop is translated into individual current reference signal for each phase. The torque is controlled by regulating these currents. Using the SRM in a variable-speed control, the phase currents are generally regulated to achieve a square wave. The simplest form of current regulation uses fixed frequency delta modulation of the phase voltages. The aim of this paper is to regulate 3-phases current of SRM by only single current sensor using delta modulation with digital chip. In this paper, the asymmetric bridge converter which is able to control independently phases and be excited simultaneously is used as the driver system for 6/4 poles SRM. And the current sensor is replaced 3 sensors of each phase with only one on bus line of converter so as to detect current of every phase. The proposed delta modulation technique has been implemented in a simple digital logic circuit using EPLD(Electrically Programmable Logic Device). This method is verified through simulation and experiment results.

오버샘플링 시그마-델타 변환기의 설계와 응용 (The Design and Application of Oversampling Sigma-Delta Converters)

  • 신종한;박송배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.861-865
    • /
    • 1991
  • Sigma delta modulation has been the preferred technique for oversampling conversion. In this paper we present the basic principles of oversampled sigma-delta Converters. Basic operation and theory behind sigma-delta modulation is reviewed. The different structures of the sigma-delta converters are described and the concepts of designing modulators and digital filters are discussed. The latest designs are also reviewed.

  • PDF

Combined Dithered Sigma-Delta Modulation based Random PWM Switching Scheme

  • Kim, Seo-Hyeong;Choi, Woo-Jin;Choi, Se-Wan;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.667-678
    • /
    • 2009
  • The PWM (Pulse Width Modulation) control signals have a drawback in that their power spectrum tends to be concentrated around the switching frequency and the resulting harmonic spikes cause an EMI (Electromagnetic Interference) and switching losses in semiconductors, etc. The SDM (Sigma-Delta Modulation) is a type of switching modulation used to reduce these harmonic spikes, and several SDM schemes are investigated in this paper. In the DSDM (Dithered SDM), the SDSDM (Space-Dithered SDM) and TDSDM (Time-Dithered SDM), the signals are classified by the location of their random dither additions. In these schemes, the switching frequency is spread by a random dither generator placed on the input or the output parts. Experimental results are presented where the advantages of the new proposed CDSDM (Combined Dithered SDM) are confirmed by applying to a buck converter.

Sigma-Delta 변조기법을 이용한 Boost Converter의 전도 노이즈 저감 (Reduction of Conducted EMI Noise in Boost Converter using Sigma-Delta Modulation Technique)

  • 이성희;최태영;구자성;원충연;김규식;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.494-497
    • /
    • 2002
  • Conducted electromagnetic interference (EMI) from switch mode power supplies (SMPS) has become a major problem due to the proliferation of these devices employing dc-dc converters using standard pulse width modulation (PWM). In this paper, we proposed the sigma-delta modulation $({\sum}{\Delta}M)$ as an alternative switching technique to reduce the conducted EMI in SMPS. A comparative investigation on conducted EMI generated by PWM and ${\sum}{\Delta}M$ techniques are experimentally performed on a 300W Boost converter.

  • PDF

인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석 (Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods)

  • 김윤호;윤병도;이병순
    • 대한전기학회논문지
    • /
    • 제41권6호
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

전류 검출기에 대한 연구 (A Study on current sensor)

  • Lee, Hwan
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.335-340
    • /
    • 1996
  • The item and structure of current detector depends on the current in conductors. The Hall current detector of these detectors is to use the variation of Hall voltage to conductor's current and it is very difficult for the conventional type to detect small current. In this paper we study experimented-method that detect AC current by using the magnetic modulation method the current, 0[mA]~100[mA]. The experiments results in 5 percent against the conventional, 20 percent in linear error, 0.12[.DELTA.mV/.DELTA.mA] to conventional type, 50[.DELTA.mV/.DELTA.mA] in sensitivity. (author). 7 refs., 15 figs.

  • PDF