• 제목/요약/키워드: Delivery quality assurance (DQA)

검색결과 14건 처리시간 0.019초

토모테라피에서 통계적공정관리를 이용한 EBT 필름 기반의 선량품질보증의 치료계획 가이드라인 (Treatment Planning Guideline of EBT Film-based Delivery Quality Assurance Using Statistical Process Control in Helical Tomotherapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.439-448
    • /
    • 2022
  • The purpose of this study was to analyze the results from statistical process control (SPC) to recommend upper and lower control limits for planning parameters based on delivery quality assurance (DQA) results and establish our institutional guidelines regarding planning parameters for helical tomotherapy (HT). A total of 53 brain, 41 head and neck (H & N), and 51 pelvis cases who had passing or failing DQA measurements were selected. The absolute point dose difference (DD) and the global gamma passing rate (GPR) for all patients were analyzed. Control charts were used to evaluate upper and lower control limits (UCL and LCL) for all assessed treatment planning parameters. Treatment planning parameters were analyzed to provide its range for DQA pass cases. We confirmed that the probability of DQA failure was higher when the proportion of leaf open time (LOT) below 100 ms was greater than 30%. LOT and gantry period (GP) were significant predictor for DQA failure using the SPC method. We investigated the availability of the SPC statistic method to establish the local planning guideline based on DQA results for HT system. The guideline of each planning parameter in HT may assist in the prediction of DQA failure using the SPC statistic method in the future.

방사선치료 시 다양한 기계학습을 이용한 선량품질관리 결과의 예측 (Prediction of Delivery Quality Assurance Via Machine Learning in Helical Tomotherapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권4호
    • /
    • pp.263-270
    • /
    • 2024
  • The objective of this study was to evaluate the accuracy and impact of leaf open time (LOT) and pitch using various machine learning models on EBT film-based delivery quality assurance (DQA) performed on 211 patients of helical tomotherapy (HT). We randomly selected passed (n=191) and failed (n=20) DQA measurements to evaluate the accuracy of the k-nearest neighbor (KNN), support vector machine (SVM), naive Bayes (NB) and logistic regression (LR) models using scale-dependent metrics such as the coefficient of determination (R2), mean squared error (MSE), and root MSE (RMSE). We evaluated the performance of the four prediction models in terms of the accuracy, precision, sensitivity, and F1-score using a confusion matrix, finding the NB and LR models to achieve optimal results. The results of this study are expected to reduce the workload of medical physicists and dosimetrists by predicting DQA results according to LOT and pitch in advance.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

방사선치료에서 환자맞춤형 선량품질보증 장치의 비교 (A Comparison of Patient-specific Delivery Quality Assurance (DQA) Devices in Radiation Therapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.231-238
    • /
    • 2023
  • This study aimed to compare the results of delivery quality assurance (DQA) using MapCHECK and OCTAVIUS for radiation therapy. Thirty patients who passed the DQA results were retrospectively included in this study. The point dose difference (DD) and gamma passing rate (GPR) were analyzed to evaluate the agreement between the measured and planned data for all cases, Plan complexity was evaluated to analyze dosimetric accuracy by quantifying the degree of modulation according to each plan. We analyzed the monitor units (MUs) and total MUs for each plan to evaluate the correlation between the MUs and plan complexity. We used a paired t-test to compare the DD and GPRs that were obtained using the two devices. The DDs and GPRs were within the tolerance range for all cases. The average GPRs difference between the two devices was statistically significant for the brain, and head and neck for gamma criteria of 3%/3 mm and 2%/2 mm. There was no significant correlation between the modulation index and total MUs for any of the cases. These DQA devices can be used interchangeably for routine patient-specific QA in radiation therapy.

토모테라피에서 선량품질보증 분석을 위한 통계적공정관리의 타당성 (Feasibility on Statistical Process Control Analysis of Delivery Quality Assurance in Helical Tomotherapy)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.491-502
    • /
    • 2022
  • The purpose of this study was to retrospectively investigate the upper and lower control limits of treatment planning parameters using EBT film based delivery quality assurance (DQA) results and to analyze the results of statistical process control (SPC) in helical tomotherapy (HT). A total of 152 patients who passed or failed DQA results were retrospectively included in this study. Prostate (n = 66), rectal (n = 51), and large-field cancer patients, including lymph nodes (n = 35), were randomly selected. The absolute point dose difference (DD) and global gamma passing rate (GPR) were analyzed for all patients. Control charts were used to evaluate the upper and lower control limits (UCL and LCL) for all the assessed treatment planning parameters. Treatment planning parameters such as gantry period, leaf open time (LOT), pitch, field width, actual and planning modulation factor, treatment time, couch speed, and couch travel were analyzed to provide the optimal range using the DQA results. The classification and regression tree (CART) was used to predict the relative importance of variables in the DQA results from various treatment planning parameters. We confirmed that the proportion of patients with an LOT below 100 ms in the failure group was relatively higher than that in the passing group. SPC can detect QA failure prior to over dosimetric QA tolerance levels. The acceptable tolerance range of each planning parameter may assist in the prediction of DQA failures using the SPC tool in the future.

단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법 (A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA))

  • 박달;김용호;김원택;김동원;김동현;전호상;남지호;임상욱
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.340-347
    • /
    • 2010
  • 단층치료기(TomoTherapy$^{(R)}$)를 이용한 방사선 치료에서 환자별 정도관리인 DQA (delivery quality assurance)는 보통 이온 전리함과 필름을 이용한다. DQA의 결과는 치료계획장비인 TomoPS (Tomo Planning Station)를 이용하여 분석하게 되는데 필름을 이용한 2차원 선량분포의 비교는 감마인덱스 분석을 사용한다. 감마인덱스를 이용한 비교는 3%/3 mm와 같은 기준을 사용하여 이 기준을 통과한 비율(pass rate)이 허용 값보다 크게 되는지 확인한다. TomoPS는 pass rate 값을 정량적으로 계산해주는 기능이 없다. 본 논문에서는 TomoPS 감마인덱스 분석의 pass rate를 정량적으로 계산하는 방법을 제시하고 이를 계산해주는 프로그램인 PassRT를 개발하였다. PassRT의 검증을 위해 I'mRT MatriXX (IBA Dosimetry, Germany)를 사용하여 측정한 세기조절방사선 치료를 받은 환자의 환자별 정도관리 자료와 필름을 사용한 DQA 자료를 사용하였다. 두 가지 종류의 자료에 대해 PassRT로 계산한 pass rate를 OmniPro I'mRT (IBA Dosimetry, Germany)프로그램으로 계산한 pass rate와 비교하였다. MatriXX를 이용하여 측정한 자료의 비교결과 평균오차 0.00%, 표준편차 0.01%, 최대오차 0.04%였고, 필름의 결과는 평균오차 0.00%, 표준편차 0.02%, 최대오차 0.02%였다. 관심영역이 $24.3{\times}16.6cm^2$ 보다 작은 경우 본 논문에서 제시한 방법으로 감마인덱스 분석의 pass rate를 소수점 첫째자리 까지 정확하게 계산할 수 있어서 보다 정확한 단층치료기의 DQA에 도움이 될 것으로 생각된다.

호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석 (Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times)

  • 윤미선;김용협;정재욱;남택근;안성자;정웅기;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.87-92
    • /
    • 2015
  • 호흡연동 래피드아크 치료는 무건운 하중의 선형가속기 갠트리의 회전과 정지의 반복과정에서 갠트리 회전 재시작점의 오차와 다엽조리개의 정확한 움직임 및 갠트리 속도와 같은 래피드아크의 선량정확도를 결정하는 요소들의 오차 가능성으로 인한 선량 오류가 발생할 수 있다. 본 연구에서는 이러한 갠트리의 회전과 정지의 반복적인 동작이 호흡연동 래피드아크 치료의 정확도에 어떠한 영향을 끼치는 지 치료 시 총 회전과 정지 동작 수를 결정하는 빔조사 구간 길이의 변화를 통해 분석하였다. 총 10명의 간암 환자를 대상으로 래피드아크 치료계획을 수립하였고, RPM 호흡연동 장치와 정확한 빔조사 구간 길이를 설정하기 위해 동적 팬텀을 사용하였다. 각 래피드아크 치료계획 당 EPID를 사용한 portal dosimetry delivery quality assurance (DQA) 계획과 이차원 다이오드 검출기배열장치인 MapCHECK2를 사용한 DQA 계획을 수립하여 호흡연동 방사선 치료과정에서 누적된 선량분포의 정확도를 분석하였다. 모든 환자의 호흡주기는 4초로 설정하였고, 수립한 DQA 계획들을 호흡연동 없이 연속적으로 조사하는 것과, 1초의 빔조사 구간과 2초의 빔조사 구간, 총 3가지의 경우에 대해 실제 방사선량 측정과 감마평가를 통해 선량의 정확도를 분석하였다. Portal dosimetry DQA 경우 평균 감마평가의 합격률은 호흡연동 없이 연속적일 때 $98.72{\pm}0.82%$ 였고, 1초의 빔조사 구간의 경우 $94.91{\pm}1.64%$, 2초의 빔조사 구간의 경우 $98.23{\pm}0.97%$이었다. MapCHECK2 DQA경우 평균 감마평가의 합격률은 호흡연동 없이 연속적일 때 $97.80{\pm}0.91%$였고, 1초의 빔조사 구간의 경우 $95.38{\pm}1.31%$, 2초의 빔조사 구간의 경우 $97.50{\pm}0.96%$였다. 본 연구 결과를 통해 빔조사 구간의 길이가 증가하여 갠트리 정지 동작 수가 감소할수록 호흡연동 래피드아크의 선량 정확도가 증가함을 확인할 수 있었으며, 이러한 특성을 호흡연동 방사선치료 대상 환자의 선정 및 호흡방식에 대한 교육과정에 고려되어야 할 것으로 판단되었다.

선속 폭(Field Width) 변화에 따른 종축선량 분석 (Analysis on Longitudinal Dose according to Change of Field Width)

  • 정원석;백종걸;신령미;오병천;조준영;김기철;최태규
    • 대한방사선치료학회지
    • /
    • 제23권2호
    • /
    • pp.109-117
    • /
    • 2011
  • 목 적: 호흡에 의하여 영향을 받는 장기의 토모 치료 시 선속 폭(Field Width) 변화에 따른 종양 용적선량의 선량 전달 정확성을 분석하고 자체 제작한 Moving car를 사용하여 선량 변화의 차이를 확인하고 실질적인 종양 선량의 전달 선량을 평가해 보고자 한다. 대상 및 방법: 자체 제작한 Moving car를 사용하여 종축 움직임 차이(0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm)를 적용하고 선속 폭(Field Width) 변화(1.05 cm, 2.50 cm, 5.02 cm)에 따른 측정된 선량의 값을 계산된 선량 값과 비교하여 오차범위를 파악하였다. Gafchromic EBT 필름을 이용하여 측정한 DQA (Delivery Quality Assurance) 필름의 감광정도를 선량윤곽(Dose Profile)과 Gamma Histogram을 이용하여 비교 분석하였다. 결 과: 선속 폭(Field Width) 1.05 cm, 2.50 cm, 5.02 cm일 때 오차범위가 각각 -2.00%, -0.39%, -2.55%의 선량 전달율을 나타내었다. Gafchromic EBT 필름 분석의 선량 윤곽(Dose profile)에서는 Moving car의 움직임이 있는 상태에서 종축방향으로의 움직임이 클수록, 선속 폭(Field Width)이 좁아질수록 고선량 부분에서 계산된 선량과의 오차가 크게 나타났다. Gamma histogram에서는 gamma index가 선속 폭(Field Width)이 좁을수록 움직임의 영향이 상당히 증가하는 것을 알 수 있었다. 결 론: 자체 제작한 Moving car를 이용하여 움직이는 장기의 종축선량 차이를 확인할 수 있었으며 토모 치료 시 선속 폭(Field Width)을 작게 하고 호흡에 의한 장기의 움직임을 최소화하기 위하여 호흡조절 장치와 고정기구의 개발이 필요하리라 사료된다.

  • PDF

토모테라피에서 계획용표적체적 설정 시 필드 폭 영향 분석 (Analysis on the Effect of Field Width in the Delineation of Planning Target Volume for TomoTherapy)

  • 송주영;나병식;정웅기;안성자;남택근;윤미선;정재욱
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.323-331
    • /
    • 2010
  • 본 연구에서는 토모테라피 Hi-Art 시스템이 제공하는 3가지(1.0 cm, 2.5 cm, 5.0 cm) 필드 폭 변화에 따른 치료부위 경계면에서의 선량 변화를 조사하여, 필드 폭 크기에 따라 PTV 설정 시 고려되어야 할 사항들을 분석하고자 하였다. 토모테라피 필드 폭 크기에 의한 PTV 양 끝단부 부위의 선량분포 변화를 알아보기 위해 토모테라피 DQA (delivery quality assurance)용 cheesecake 팬텀을 대상으로 각 필드 폭 크기별 토모 치료계획을 수립하여 선량계산 결과와 실제 필름에서의 선량분포를 비교, 분석하였고, 실제 환자를 대상으로 한 치료계획에서도 필드 폭 크기의 영향을 살펴보고자, 복부부위를 치료했던 환자 4명을 대상으로 각 필드 별 치료계획을 세우고, 선량분포를 분석하였다. DQA 팬텀을 대상으로 분석한 결과, 선량계산 값과 조사된 필름분석 결과 모두에서 필드 폭 크기가 커질수록 PTV 양끝단 부위의 선량분포가 더 넓게 분포함을 확인할 수 있었다. Jaw의 폭 변화 방향인 세로(y)방향의 선량분포에서 1.0 cm 필드 크기와 비교하여 최대 선량값 50% 기준으로 2.5 cm 필드는 1.6 cm 더 넓은 선량분포를, 5.0 cm 필드는 4.2 cm 더 넓은 선량분포를 보였다. 실제 환자 데이터를 대상으로 분석한 결과, 4명 모두 필드 폭 크기가 증가함에 따라 PTV y축 양끝 경계면에서 더 많은 선량이 더 넓게 분포함을 알 수 있었다. 특히, 5.0 cm 필드 폭을 사용하였을 경우에는 처방선량에 가까운 높은 선량이 PTV 양끝 상당히 넓은 영역에 걸쳐 조사됨을 알 수 있었으며, 이를 통해 큰 필드 폭을 기준으로 토모테라피 치료계획을 수립할 경우에는 치료기 테이블 진행방향으로 PTV 양끝 경계면에서 기존보다 여유도(margin)를 축소하여 PTV 설정을 하는 것이 타당함을 확인할 수 있었다.