• Title/Summary/Keyword: Delivery Time Window

Search Result 46, Processing Time 0.023 seconds

Client-Based Video-On-Demand System Implementation using Multicast (멀티캐스트를 이용한 사용자 기반의 비디오 주문형 시스템 구현)

  • Hwang, Tae-June;Kim, Back-Hyun;Ik, Soo-Kim
    • Journal of Internet Computing and Services
    • /
    • v.6 no.6
    • /
    • pp.127-137
    • /
    • 2005
  • This paper presents implementation of client-based VOD service using multicast delivery, Conventional system provide server-based system in multicast delivery but implemented system provides on-demand client-based multicast system. The Multicast Agent Scheduler aggregates clients' request and it generate multicast group addresses and port numbers according to requested video items and service request time. Then it transmits immediately multicast address to VOD server and client who request service. And then VOD server transmits requested streams with a multicast group address and the client joins the group automatically. The Multicast Agent Scheduler assigns the same multicast group address when other clients request an identical video within the same scheduling duration. The proposed system can reduce load of server and support many clients at the same time and applies it to WMT(window media technology) of Microsoft.

  • PDF

A Smoothing Data Cleaning based on Adaptive Window Sliding for Intelligent RFID Middleware Systems (지능적인 RFID 미들웨어 시스템을 위한 적응형 윈도우 슬라이딩 기반의 유연한 데이터 정제)

  • Shin, DongCheon;Oh, Dongok;Ryu, SeungWan;Park, Seikwon
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.1-18
    • /
    • 2014
  • Over the past years RFID/SN has been an elementary technology in a diversity of applications for the ubiquitous environments, especially for Internet of Things. However, one of obstacles for widespread deployment of RFID technology is the inherent unreliability of the RFID data streams by tag readers. In particular, the problem of false readings such as lost readings and mistaken readings needs to be treated by RFID middleware systems because false readings ultimately degrade the quality of application services due to the dirty data delivered by middleware systems. As a result, for the higher quality of services, an RFID middleware system is responsible for intelligently dealing with false readings for the delivery of clean data to the applications in accordance with the tag reading environment. One of popular techniques used to compensate false readings is a sliding window filter. In a sliding window scheme, it is evident that determining optimal window size intelligently is a nontrivial important task in RFID middleware systems in order to reduce false readings, especially in mobile environments. In this paper, for the purpose of reducing false readings by intelligent window adaption, we propose a new adaptive RFID data cleaning scheme based on window sliding for a single tag. Unlike previous works based on a binomial sampling model, we introduce the weight averaging. Our insight starts from the need to differentiate the past readings and the current readings, since the more recent readings may indicate the more accurate tag transitions. Owing to weight averaging, our scheme is expected to dynamically adapt the window size in an efficient manner even for non-homogeneous reading patterns in mobile environments. In addition, we analyze reading patterns in the window and effects of decreased window so that a more accurate and efficient decision on window adaption can be made. With our scheme, we can expect to obtain the ultimate goal that RFID middleware systems can provide applications with more clean data so that they can ensure high quality of intended services.

Online Fitting service Study -Focusing on Interface design (온라인 피팅서비스 디자인 연구 -인터페이스 디자인을 중심으로)

  • Kim, Ryu-Hee;Yang, Sung-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • This study focused on the fitting window structure provided by the virtual fitting service web page. We analyzed the current cases and identified the user's needs for the service through usability assessment, survey, and FGI experiments. As a result of the design, the fitting window of the existing web page was opened at the same time as the site was accessed to improve the hassle of using the icons due to their small size and poor visibility. In the case of fitting windows, the problem of information delivery was supplemented so that even the initial user could understand the fitting map of the existing method, and additional items needed for user propensity were provided so that the service could be used accurately and easily. As a result of this study, it can be used as a basic research material in future virtual fitting service studies and is expected to provide good implications to fashion marketers.

Development of Gastric Retentive Bi-layered Tablet using Floating Drug Delivery System (부유 기술을 이용한 위체류 이중정의 개발)

  • Park, Jun-Bom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7549-7554
    • /
    • 2015
  • The aim of this study was to develop gastric retentive bi-layered tablet using floating drug delivery technique. Metformin was selected as a model drug due to its narrow absorption window as well as very highly water solubility. These properties of metformin led to be difficult controlling the drug release. The bi-layered tablet was prepared with bi-layered compression machine to minimize interference between floating part and controlling part. The tablet weight, appearance and hardness were evaluated after compression process. The times of 'time to floating' and 'Floating duration' were tested for floating ability and drug release study was also carried out to understand drug release behavior. Furthermore, the drug release of bi-layered tablet was compared with marketed metformin tablet with sustained release pattern (Glucopharge XR$^{(R)}$).The floating ability and drug release behaviors were well controlled by changing amounts of $NaHCO_3$ (floating substance) and hydroxypropyl methylcellulose (HPMC; release control material). Bi-layered tablet had 13s of time to float, over 10h of floating duration and very similar drug release behavior compared with Glucopharge XR$^{(R)}$($f_2$: 89.6). Consequently, the bi-layered tablet with floating ability was successfully prepared and these properties can maximize the efficacy of metformin.

Exploring the Feasibility of Differentiating IEEE 802.15.4 Networks to Support Health-Care Systems

  • Shin, Youn-Soon;Lee, Kang-Woo;Ahn, Jong-Suk
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.132-141
    • /
    • 2011
  • IEEE 802.15.4 networks are a feasible platform candidate for connecting all health-care-related equipment dispersed across a hospital room to collect critical time-sensitive data about patient health state, such as the heart rate and blood pressure. To meet the quality of service requirements of health-care systems, this paper proposes a multi-priority queue system that differentiates between various types of frames. The effect of the proposed system on the average delay and throughput is explored herein. By employing different contention window parameters, as in IEEE 802.11e, this multi-queue system prioritizes frames on the basis of priority classes. Performance under both saturated and unsaturated traffic conditions was evaluated using a novel analytical model that comprehensively integrates two legacy models for 802.15.4 and 802.11e. To improve the accuracy, our model also accommodates the transmission retries and deferment algorithms that significantly affect the performance of IEEE 802.15.4. The multi-queue scheme is predicted to separate the average delay and throughput of two different classes by up to 48.4% and 46%, respectively, without wasting bandwidth. These outcomes imply that the multi-queue system should be employed in health-care systems for prompt allocation of synchronous channels and faster delivery of urgent information. The simulation results validate these model's predictions with a maximum deviation of 7.6%.

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF

Mean Response Delay Estimation for HTTP over SCTP in Wireless Internet (무선 인터넷 환경에서 HTTP over SCTP의 평군 응답 시간 추정)

  • Lee, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.43-53
    • /
    • 2008
  • Hyper text transfer protocol (HTTP) over transmission control protocol (TCP) is currently used to transfer objects in the Internet. Stream control transmission protocol (SCTP), an alternative to TCP, which allows for independent delivery among streams, and can thus reduce the mean response delay of web object. We present an analytical model to find the mean response delay for HTTP over SCTP, therefore, estimate the effectiveness of SCTP over TCP. Typical TCP delay models assume the wired environment. On the contrary, the proposed model in this paper assumes the multiple packet losses and wireless environment where fast retransmission is not possible due to small window. The estimated mean response time can be used the benchmark to meet quality of service (QoS) at end-user. We validate the accuracy of our model using experiments. It is shown that the differences between the results from model and those from experimental are very small below 6 % on average. We also find that the mean response delay for HTTP over SCTP is less than that for HTTP over TCP.

MU Fluence Reconstruction based-on Delivered Leaf Position: for IMRT Quality Assurance (세기조절방사선치료의 정도관리를 위한 모니터유닛 공간분포 재구성의 효용성 평가)

  • Park, So-Yeon;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • The measurement-based verification for intensity modulated radiation therapy (IMRT) is a time-and labor-consuming procedure. Instead, this study aims to develop a MU fluence reconstruction method for IMRT QA. Total actual fluences from treatment planning system (TPS, Eclipse 8.6, Varian) were selected as a reference. Delivered leaf positions according to MU were extracted by the dynalog file generated after IMRT delivery. An in-house software was develop to reconstruct MU fluence from the acquired delivered leaf position data using MATLAB. We investigated five patient's plans delivered by both step-and-shoot IMRT and sliding window technologies. The total actual fluence was compared with the MU fluence reconstructed by using commercial software (Verisoft 3.1, PTW) and gamma analysis method (criteria: 3%/3 mm and 2%/1 mm). Gamma pass rates were $97.8{\pm}1.33$% and the reconstructed fluence was shown good agreement with RTP-based actual fluence. The fluence from step and shoot IMRT was shown slightly higher agreement with the actual fluence than that from sliding window IMRT. If moving from IMRT QA measurements toward independent computer calculations, the developed method can be used for IMRT QA. A point dose calculation method from reconstructed fluences is under development for the routine IMRT QA purpose.

Dynamic Resource Reservation for Ultra-low Latency IoT Air-Interface Slice

  • Sun, Guolin;Wang, Guohui;Addo, Prince Clement;Liu, Guisong;Jiang, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.7
    • /
    • pp.3309-3328
    • /
    • 2017
  • The application of Internet of Things (IoT) in the next generation cellular networks imposes a new characteristic on the data traffic, where a massive number of small packets need to be transmitted. In addition, some emerging IoT-based emergency services require a real-time data delivery within a few milliseconds, referring to as ultra-low latency transmission. However, current techniques cannot provide such a low latency in combination with a mice-flow traffic. In this paper, we propose a dynamic resource reservation schema based on an air-interface slicing scheme in the context of a massive number of sensors with emergency flows. The proposed schema can achieve an air-interface latency of a few milliseconds by means of allowing emergency flows to be transported through a dedicated radio connection with guaranteed network resources. In order to schedule the delay-sensitive flows immediately, dynamic resource updating, silence-probability based collision avoidance, and window-based re-transmission are introduced to combine with the frame-slotted Aloha protocol. To evaluate performance of the proposed schema, a probabilistic model is provided to derive the analytical results, which are compared with the numerical results from Monte-Carlo simulations.

Pharmacokinetic Evaluation of Ketorolac Tromethamine Sustained-Release Pellets after Oral Administration in Rabbits (케토롤락트로메타민 서방성 펠렛의 약물속도론적 평가)

  • Kwak, Son-Hyok;Hwang, Sung-Joo;Jiang, Ge;Nam, Kyung-Wan;Moon, Young-Girl;Lee, Hai-Bang;Cho, Sun-Hang;Yuk, Soon-Hong;Lee, Han-Koo;Jeong, Sang-Young;Lee, Young-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.241-246
    • /
    • 2000
  • To develop a sustained-release preparation containing ketorolac tromethamine, two sustained-release pellet formulations were evaluated with a pharmacokinetic study as compared with a conventional commercial tablets (10 mg $Tarasyn^{TM}$, Roche Korea Ltd.). Two sustained-release formulations were as follows; formulation A was composed of an inner layer containing 75% of drug coated with $Eudragit^{TM}$ RS 100 membrane and an outer layer containing 25% of drug mixed with $Eudragit^{TM}$ NE30D, and formulation B was composed of only an inner layer containing 100% of drug coated with $Eudragit^{TM}$ RS 100 membrane. The dissolution test was performed for two formulations. In case of conventional tablets, 2.5 mg of drug per a dose was administered orally into male Albino rabbit (2.0-2.3 kg of body weight) 3 times at intervals of 4 hours. In case of two sustained formulations, 7.5 mg of drug was administered once orally. Blood samples were withdrawn periodically after the administration, and the blood concentration was determined by HPLC. The conventional tablets showed very high peak-trough fluctuation between administered doses, but two sustained formulations showed less fluctuation. Formulation A with the loading dose showed the time to reach minimum effective concentration (MEC) i.e. the onset time was less than 20 min, while Formulation B had more than 1 hr of the onset time. Formulation A had the more constant plasma level than formulation B. However, formulation B had a time lag, so the plasma level was less than MEC for an initial period of 1 hr. In formulation A, the plasma level was maintained within the therapeutic window $(0.3-5\;{\mu}g/ml)$ for a long period. Formulation A was thought to be an ideal sustained-release formulation for ketorolac tromethamine oral delivery system.

  • PDF