• 제목/요약/키워드: Degradation of material

검색결과 1,594건 처리시간 0.03초

ZnO 나노파우더로 제조된 Bi계 바리스터의 가속열화 특성 (The Characteristics on the Accelerated Degradation of Bi-based Varistor fabricated with ZnO Nano-powder)

  • 왕민성;왕증매;이동규;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.203-204
    • /
    • 2006
  • Nano-Varistors fabricated with ZnO 30nm and 80nm powders were studied about the electrical characteristics with AC accelerated degradation in this paper Especially, ZnO nano-powder varistors were sintered m air at $1050^{\circ}C$ and analyzed the phenomenons of before and after AC degradation test. The stress conditions of AC degradation test were $1.0V_{1mA}$ $115{\pm}2^{\circ}C$ for 24h. 80nm-varistor was exhibited better performance than 30nm-varistor m the electrical stabilities. And then 80nm-varistor resulted m the degradation characteristics that the variation rate of operating voltage, nonlinear coefficient and leakage current was -0 3%, -0 4% and -3 3%, respectively.

  • PDF

표면열화진단을 위한 적외선카메라의 응용 (The Application of IRR-Camera for the Diagnosis of Surface Degradation)

  • 임장섭;정승천;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.61-65
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

적외선방사카메라를 이용한 트래킹열화 온도분포 (Temperature Distribution of Tracking Degradation Using IRR-Camera)

  • 정승천;임장섭;천종철;정우성;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Sliding Wear Behavior of UHMWPE against Novel Low Temperature Degradation-Free Zirconia/Alumina Composite

  • Lee, K.Y.;Lee, M.H.;Lee, Y.H.;Seo, W.S.;Kim, D.J.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.365-366
    • /
    • 2002
  • The sliding wear behavior of ultra high molecular weight polyethylene (UHMWPE) was examined on a novel low temperature degradation-free zirconia/alumina composite material and conventional alumina and zirconia ceramics used for femoral head in total hip joint replacement. The wear of UHMWPE pins against these ceramic disks was evaluated by performing linear reciprocal sliding and repeat pass rotational sliding tests for one million cycles in bovine serum. The weight loss of polyethylene against the novel low temperature degradation-free zirconia/alumina composite disks was much less than those against conventional ceramics for all tests. The mean weight loss of the polyethylene pins was more io the linear reciprocal sliding test than in the repeal pass rotational sliding lest for all kinds of disk materials. Neither the coherent transfer film nor the surface damage was observed on the surface of the novel zirconia/alumina composite disks during the test. The observed r,'stilts indicated that the wear of the polyethylene was closely related to contacting materials and kinematic motions. In conclusion, the novel zirconia/alumina composite leads the least wear of polyethylene among the tested ceramics and demonstrates the potential as lhe alternative materials for femoral head in total hip joint replacement.

  • PDF

EPR 케이블의 절연열화 특성의 평가 (Estimate of Insulated Degradation Propertied Of EPR cable)

  • 이성일;류성림;김귀열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.233-236
    • /
    • 2002
  • This paper describes the properties of between the residual voltage for ${\gamma}$-irradiated in electric power cable using in nuclear power generating station. As these properties related with ${\gamma}$-irradiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation. From theory and experiment We found the residual voltage is not influenced by cable length. We found that residual voltage of basic composite and practical composite have not a difference an occasion be the same cable length. As the ratio of degradation increases, the residual voltage in the initial time range increases and the peak moves to the shorter time. Therefore, We can know the degree of radiation degradation from the position of the peak.

  • PDF

Bio 필터를 이용한 Toluene 제거에서 미생물분해에 관한 연구 (A Study on Microbial Degradation for Removal of Toluene Vapour by Biofilter)

  • 하상안;강신묵
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.24-30
    • /
    • 1999
  • A biological filter for treatment of toluene among volatile organic compounds was studied. The investigation was conducted using specially built stainless steel columns packed with granular activated carbon and cold for removal of toluene. The G.A. and mold as filter material was also coated with Pseudomonas putida microorganisms.The biofilter unit was operated in the condition of moisture content vairation at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C equipped with F.I.d detector. The removal efficiency of gaseous toluene was 95% at average inlet concentration of 950 ppm during bio-degradation operating condition. Effective removal efficiency was obtained with moisture content 27.5% at activated carbon and 32% at mold in this study. The effective operating condition were obtained with pH 6-8, temperature 28-42℃ for microbial degradation at gas loading rate of 12.5 l/min in packed material.

  • PDF

바크하우젠 노이즈 해석에 의한 재료의 열화도 평가 (Degradation Estimation Of Material by Barkhausen Noise Analysis)

  • 이명호
    • 한국공작기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.38-46
    • /
    • 2005
  • The destructive method is reliable and widely used for the estimation of material degradation but it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. In this study, various nondestructive evaluation(NDE) parameters of the Barkhausen noise method, such as MPA(Maximum Peak Amplitude), RMS, IABNS(Internal Area of Barkhausen Noise on Signal) and average amplitude of frequency spectrum are investigated and correlated with thermal damage level of 2.25cr-1.0Mo steel using wavelet analysis. Those parameters tend to increase while thermal degradation proceeds. It also turns out that the wavelet technique can help to reduce experimental false call in data analysis.

EPR 케이블의 잔류전압에 미치는 방사선의 영향 (Effect of Radial Rays on Residual Voltage for EPR cable)

  • 이성일;류성림;김용추
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.518-521
    • /
    • 1999
  • This paper describes the properties of discharge current and the residual voltage for $^{60}$ C$_{0}$ -${\gamma}$ irradiated cables using in nuclear power generating station. As these properties related with $^{60}$ C$_{0}$ -${\gamma}$ -irradiatiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation. As the ratio of degradation increases, the residual voltage in the initial time range increases and the peak moves to the shorter time. Therefore, I know the degree of radiation degradation from the position of the peak.

  • PDF

핫 캐리어 신뢰성 개선을 위한 새로운 LDD 구조에 대한 연구 (A Study on New LDD Structure for Improvements of Hot Carrier Reliability)

  • 서용진;김상용;이우선;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-6
    • /
    • 2002
  • The hot carried degradation in a metal oxide semiconductor device has been one of the most serious concerns for MOS-ULSI. In this paper, three types of LDD(lightly doped drain) structure for suppression of hot carried degradation, such as decreasing of performance due to spacer-induced degradation and increase of series resistance will be investigated. in this study, LDD-nMOSFETs used had three different drain structure, (1) conventional surface type LDD(SL), (2) Buried type LDD(BL), (3) Surface implantation type LDD(SI). As experimental results, the surface implantation the LDD structure showed that improved hot carrier lifetime to comparison with conventional surface and buried type LDD structures.

방사선 열화에 따른 PEEK의 유전특성과 동적 기계적 특성 (Dielectric Analysis and Dynamic Mechanical Analysis of Radiation Degradation of PEEK)

  • 김기엽;강현구;류부형;이청;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.485-488
    • /
    • 2003
  • Radiation degradation of Poly(ether ether ketone) (PEEK) has been studied by dielectric analysis and dynamic mechanical analysis. It has been observed that dielectric properties are influenced by radiation degradation of PEEK. For radiation degradation of PEEK, dynamic mechanical properties were insensible.

  • PDF