• Title/Summary/Keyword: Defect Assessment

Search Result 247, Processing Time 0.03 seconds

The Nutritional Assessment in Children - Understanding of Anthropometric Assessment and Biochemical Indexes in Children (소아의 영양 평가 - 소아 신체계측과 생화학적 지표의 특성을 중심으로)

  • Park, Kie Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.12 no.sup1
    • /
    • pp.6-11
    • /
    • 2009
  • Nutritional assessment is based on anthropometric, clinical, dietary and biochemical data. There is a lack of studies about the propriety of biochemical indexes for the nutritional assessment in children despite biochemical data in pediatric population are different from them in adult's in many respects. Serum albumin is useful index to evaluate the severity of malnutrition. Hemoglobin and hematocrit tend to decrease in malnutrition on account of defect of iron metabolism and to increase in metabolic syndrome on account of enhancement of erythropoiesis. But, unlike adult, total lymphocyte count is not so useful biochemical indexes in children. We should consider pediatric characteristic when interpret biochemical indexes for nutritional assessment in children, and nutritional status in children should be assessed comprehensively with anthropometric, clinical, dietary and biochemical data.

Design and Implementation of a Data-Driven Defect and Linearity Assessment Monitoring System for Electric Power Steering (전동식 파워 스티어링을 위한 데이터 기반 결함 및 선형성 평가 모니터링 시스템의 설계 구현)

  • Lawal Alabe Wale;Kimleang Kea;Youngsun Han;Tea-Kyung Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.2
    • /
    • pp.61-69
    • /
    • 2023
  • In recent years, due to heightened environmental awareness, Electric Power Steering (EPS) has been increasingly adopted as the steering control unit in manufactured vehicles. This has had numerous benefits, such as improved steering power, elimination of hydraulic hose leaks and reduced fuel consumption. However, for EPS systems to respond to actions, sensors must be employed; this means that the consistency of the sensor's linear variation is integral to the stability of the steering response. To ensure quality control, a reliable method for detecting defects and assessing linearity is required to assess the sensitivity of the EPS sensor to changes in the internal design characters. This paper proposes a data-driven defect and linearity assessment monitoring system, which can be used to analyze EPS component defects and linearity based on vehicle speed interval division. The approach is validated experimentally using data collected from an EPS test jig and is further enhanced by the inclusion of a Graphical User Interface (GUI). Based on the design, the developed system effectively performs defect detection with an accuracy of 0.99 percent and obtains a linearity assessment score at varying vehicle speeds.

Integrated Fitness-for-service Program for Natural Gas Transmission Pipeline (천연가스 공급배관의 사용적합성 통합프로그램)

  • Kim, Woo-Sik;Kim, Young-Pyo;Kim, Cheol-Man;Baek, Jong-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.269-274
    • /
    • 2008
  • For fitness-for-service analyses of underground natural gas pipelines, engineering assessment methods against possible defects need to be developed. The assessment methods for high pressure pipeline of KOGAS, was developed using the full size pipe burst tests and the finite element analysis. It included the defect assessment methods for a single and multi-corrosion, corrosion in girth welding part, corrosion in seam welding part, the mechanical damage defects as dent and gouge, crack and large plastic deformation of API 5L X65 pipe. In addition, we developed method to assess pipeline integrity by internal and external load to buried pipeline. Evaluation results were compared with other methods currently being applied to the gas pipeline. The program of Windows environment is made for easily using assessment methods. It provides a consistent user interface, so non-professional technician can easily and friendly use the FFS program from company intranet. Several evaluation programs is easily installed using one installer. Each program constitutes a common input interface and the output configuration program, and evaluation result store and can be recalled at any time. The FFS program based on independent evaluation method is used to evaluate the integrity and safety of KOGAS pipeline, and greatly contribute to safe and efficient operation of pipeline. This paper presents experimental, analytical and numerical investigations to develop the FFS methods for KOGAS pipeline, used as high pressure natural gas transmission pipeline within KOREA. Also, it includes the description of the integrated program for FFS methods.

  • PDF

Long-term radiographic evaluation of GTR treatment in intrabony defect (골연하 결손부에서 조직유도재생술의 장기적 방사선학적 변화 관찰)

  • Choi, Mi-Hye;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.181-192
    • /
    • 2007
  • Periodontal surgery as part of the treatment of periodontal disease is mainly performed 1) to gain access to diseased areas for adequate cleaning; 2) to achieve pocket reduction or elimination; and 3) to restore the periodontal tissues lost through the disease; i.e., a new attachment formation of periodontal regeneration. To accomplish the latter, often referred to as the ultimate goal of periodontal therapy, a number of surgical procedures have been advocated throughout the years. Clinical studies have demonstrated that considerable gain of clinical attachment and bone can be achieved following guided tissue regeneration (GTR) therapy of intrabony defects. The aim of this study was to analyse the radiographic bone changes 2-year after GTR using a bone graft material and nonresorbable membrane. Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of intrabony defect(s), 33 sites of 30 patients aged 32 to 56 (mean age 45.6) were treated by GTR with a bone graft material and nonresorbable membrane. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. We observed $2.86{\pm}1,87mm$ of bone fill, $065{\pm}0.79mm$ of crestal resorption, $3.49{\pm}2.11mm$ of defect resolution, and $44.42{\pm}19.51%$ of percentage of defect resolution. Mandible, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. But no difference was observed between xenograft and allograft. Outcome of GTR as a therapy of intrabony defect was better than other therapy, but herein, good oral hygiene maintenance as a anti-infective treatment and periodic recall check of patients are essential.

Incidental occurrence of an unusually large mastoid foramen on cone-beam computed tomography and review of the literature

  • Syed, Ali Z.;Sin, Cleo;Rios, Raquel;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • The incidental finding of an enlarged mastoid foramen on the right posterior mastoid region of temporal bone is reported, together with a discussion of its clinical significance. A 67-year-old female underwent the pre-implant assessment of a maxillary left edentulous region. A cone-beam computed tomographic (CBCT) image was acquired and referred for consultation. Axial CBCT slices revealed a unilateral, well-defined, noncorticated, low-attenuation, transosseous defect posterior to the mastoid air cells in the right temporal bone. The borders of the osseous defect were smooth and continuous. No other radiographic signs suggestive of erosion or sclerosis were noted in the vicinity. The density within the defect was homogenous and consistent with a foramen and/or soft tissue. The patient's history and physical examination revealed no significant medical issues, and she was referred to a neuroradiologist for a second opinion. The diagnosis of an enlarged mastoid foramen was made and the patient was reassured.

Consequence of Synthetic Bone Substitute Used for Alveolar Cleft Graft Reconstruction (Preliminary Clinical Study)

  • Rawaa Y. Al-Rawee;Bashar Abdul-Ghani Tawfeeq;Ahmed Mothafar Hamodat;Zaid Salim Tawfek
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.478-487
    • /
    • 2023
  • Background The outcome of alveolar grafting with synthetic bone substitute (Osteon III) in various bone defect volumes is highlighted. Methods A prospective study was accomplished on 55 patients (6-13 years of age) with unilateral alveolar bone cleft. Osteon III, consisting of hydroxyapatite and tricalcium phosphate, is used to reconstruct the defect. Alveolus defect diameter was calculated before surgery (V1), after 3 months (V2), and finally after 6 months (V3) postsurgery. In the t-test, a significant difference and correlation between V1, V2, and V3 are stated. A p-value of 0.01 is considered a significant difference between parameters. Results The degree of cleft is divided into three categories: small (9 cases), medium (20 patients), and large (26 cases).The bone volume of the clefted site is divided into three steps: volume 1: (mean 18.1091 mm3); step 2: after 3 months, volume 2 resembles the amount of unhealed defect (mean 0.5109 mm3); and the final bone volume assessment is made after 6 months (22.5455 mm3). Both show statistically significant differences in bone volume formation. Conclusion An alloplastic bone substitute can also be used as a graft material because of its unlimited bone retrieval. Osteon III can be used to reconstruct the alveolar cleft smoothly and effectively.

Defect Depth Measurement of Straight Pipe Specimen Using Shearography (전단간섭계를 이용한 직관시험편의 결함 깊이 측정)

  • Chang, Ho-Seob;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.170-176
    • /
    • 2012
  • In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment.

Assessment of Defect Risks in Apartment Projects based on the Defect Classification Framework (효율적인 품질관리를 위한 공동주택 하자위험 분석)

  • Jang, Ho-Myun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.510-519
    • /
    • 2019
  • The aim of this study was to set a defect classification framework and evaluate the defect risks in apartment buildings For this, approximately 15,056 defect items for 133 apartment buildings were examined. As a result of the analysis, the major defect of the RC work was cracks, which were found mainly in public locations. Moreover, the RC work was found to exhibit a high defect risk of water problem and surface appearance, which are highly connected with cracks. Second, the finish work has a high defect risk because it is composed of various work types, and there are many kinds of materials and construction parts involved. Third, the major defects of the waterproof work were incorrect installation and missing tasks, which have high defect risks in the garage. This is because defects that require rework occur mainly in the underground garage. Based on these results, this study proposed countermeasures for defect risk management to be considered in the construction, handover, post-handover, and occupancy phases. These have been set in detail based on the three zones: low frequency high severity (LFHS), low frequency low severity (LFLS), and high frequency low severity (HFLS).

Reliability Assessment Methods for Electronic Component Removed Environmental Materials - focused on Printed Wiring Board without Pb and Br - (환경물질을 제외한 전자부품의 신뢰성평가 방법 연구 - Pb와 Br을 제거한 PWB를 중심으로 -)

  • Lee, Jong-Beom;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.04a
    • /
    • pp.381-391
    • /
    • 2006
  • When the environmental materials of the raw and sub material to applied in electronic goods removed, the reliability assessment and the forecasting is stand on the low level and in case of neglect, it is acting as latent defect that can be connected to large size disaster. In this research, the study on the management method of environmental restriction substances which is recognized as important element in the reliability assessment about environmental material of electronic goods and the study on reliability assessment method of PWB without environmental material are progressed

  • PDF

Developing a Quality Risk Assessment Model for Product Liability Law (제조물 책임(PL)법 대응을 위한 품질 리스크 진단 모델 개발)

  • Oh, Hyung Sool
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.3
    • /
    • pp.27-37
    • /
    • 2017
  • As the global uncertainty of manufacturing has increased and the quality problem has become global, the recall has become a fatal risk that determines the durability of the company. In addition, as the convergence of PSS (product-service system) product becomes common due to the development of IT convergence technology, if the function of any part of hardware or software does not operate normally, there will be a problem in the entire function of PSS product. In order to manage the quality of such PSS products in a stable manner, a new approaches is needed to analyze and manage the hardware and software parts at the same time. However, the Fishbone diagram, FTA, and FMEA, which are widely used to interpret the current quality problem, are not suitable for analyzing the quality problem by considering the hardware and software at the same time. In this paper, a quality risk assessment model combining FTA and FMEA based on defect rate to be assessed daily on site to manage quality and fishbone diagram used in group activity to solve defective problem. The proposed FTA-FMEA based risk assessment model considers the system structure characteristics of the defect factors in terms of the relationship between hardware and software, and further recognizes and manages them as risk. In order to evaluate the proposed model, we applied the functions of ITS (intelligent transportation system). It is expected that the proposed model will be more effective in assessing quality risks of PSS products because it evaluates the structural characteristics of products and causes of defects considering hardware and software together.