• 제목/요약/키워드: Deadbeat control

검색결과 117건 처리시간 0.019초

최소 차원 상태관측기를 사용한 DeadBeat 제어 PWM인버터의 실현 (Realization of DeadBeat Controlled PWM Inverter using Reduced-Order State Observer)

  • 이채동;신동률;정봉출;김종석;조윤현;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.281-283
    • /
    • 1995
  • Deadbeat controlled PWM Inverter is realized. This PWM inverter performs the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. For the deadbeat current controller, the system's order becomes a high order and increases computation delay time. Therefore, The delay tine produces current ripple. To minimize the current ripple, a new method based on deadbeat control theory for current regulation is proposed. It is constructed by a reduced-order state observer which predicts the output current in next sampling instant.

  • PDF

무손실 공진기를 이용한 능동전력필터의 Deadbeat제어 (Deadbeat Control of Active Power Filter using Lossless Resonator)

  • 박지호;노태균;김춘삼;안인모;우정인
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.350-353
    • /
    • 1999
  • In this paper, a new simple control method for active power filter which can realized the complete compensation of the harmonic currents is proposed. In the proposed scheme, a compensating current reference generator employing lossless resonato implemented by a DSP(Digital Signal Processor) is introduced. Deadbeat control is employed to contro the active power filter. The switching pulse width based SVM(Space Vector Modulation) is adopted so that the current of active power filter is been exactly equal to its reference at the next sampling instant. To compensate the computation delay of digital controller, the prediction of current is achieved by the current observer with deadbeat response.

  • PDF

직류 전동기의 유한 시간 정정 응답 제어 (Speed Control of D.C Motor based on Deadbeat Response)

  • 김영석;유완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.371-374
    • /
    • 1990
  • This paper presents the speed control of dc motor based on deadbeat response. The deadbeat response is that the output reaches the final value in the minimum possible settling time and stays there. This results demonstrate that the output reaches final value in one sampling time for the unsaturated region, and in one sampling time after getting free from the saturation state for the saturated region.

  • PDF

외란관측기를 사용한 복합형능동전력필터의 Deadbeat 제어에 관한 연구 (Deadbeat control of Hybrid Active Power filter using Distrubance-observer)

  • 조광승
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.123-126
    • /
    • 2000
  • When LC filter is connected parallel to the Active Power Filter a problem of the resonance between the Active Power Filter(AF) and LC filte often arises. in this paper Deadbeat control of Hybrid Active Power Filter using Disturbance-observer is introduced to solve this problem. By the estimation of the harmonics disturbance using proposed disturbance observer the compensation characteristics of the AF is improved and the resonant current is suppressed. The validity of proposed disturbance observer is verified from simulation results using PSIM

  • PDF

Deadbeat and Hierarchical Predictive Control with Space-Vector Modulation for Three-Phase Five-Level Nested Neutral Point Piloted Converters

  • Li, Junjie;Chang, Xiangyu;Yang, Dirui;Liu, Yunlong;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1791-1804
    • /
    • 2018
  • To achieve a fast dynamic response and to solve the multi-objective control problems of the output currents, capacitor voltages and system constraints, this paper proposes a deadbeat and hierarchical predictive control with space-vector modulation (DB-HPC-SVM) for five-level nested neutral point piloted (NNPP) converters. First, deadbeat control (DBC) is adopted to track the reference currents by calculating the deadbeat reference voltage vector (DB-RVV). After that, all of the candidate switching sequences that synthesize the DB-RVV are obtained by using the fast SVM principle. Furthermore, according to the redundancies of the switch combination and switching sequence, a hierarchical model predictive control (MPC) is presented to select the optimal switch combination (OSC) and optimal switching sequence (OSS). The proposed DB-HPC-SVM maintains the advantages of DBC and SVM, such as fast dynamic response, zero steady-state error and fixed switching frequency, and combines the characteristics of MPC, such as multi-objective control and simple inclusion of constraints. Finally, comparative simulation and experimental results of a five-level NNPP converter verify the correctness of the proposed DB-HPC-SVM.

Low Parameter Sensitivity Deadbeat Direct Torque Control for Surface Mounted Permanent Magnet Synchronous Motors

  • Zhang, Xiao-Guang;Wang, Ke-Qin;Hou, Ben-Shuai
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1211-1222
    • /
    • 2017
  • In order to decrease the parameter sensitivity of deadbeat direct torque control (DB-DTC), an improved deadbeat direct torque control method for surface mounted permanent-magnet synchronous motor (SPMSM) drives is proposed. First, the track errors of the stator flux and torque that are caused by model parameter mismatch are analyzed. Then a sliding mode observer is designed, which is able to predict the d-q axis currents of the next control period for one-step delay compensation, and to simultaneously estimate the model parameter disturbance. The estimated disturbance of this observer is used to estimate the stator resistance offline. Then the estimated resistance is required to update the designed sliding-mode observer, which can be used to estimate the inductance and permanent-magnetic flux linkage online. In addition, the flux and torque estimation of the next control period, which is unaffected by the model parameter disturbance, is achieved by using predictive d-q axis currents and estimated parameters. Hence, a low parameter sensitivity DB-DTC method is developed. Simulation and experimental results show the validity of the proposed direct control method.

실시간 디지털 궤환 제어(Deadbeat 제어)에 의한 전류 제어형 PWM 인버터에 관한 연구 (Current Controlled PWN Inverter Using the Real-time Digital Feedback Control)

  • Lee, Jeong-Uk;Yoo, Ji-Yoon;Ahn, Ho-Gyun
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.259-267
    • /
    • 1994
  • This paper describes a current control of a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. The deadbeat current controller is proposed to control the output current regardless of load component variations by the same method as voltage control. That is, in current control, with a very short sampling time and the successive feedback of the output current, the load current is mainly effected by the magnitude of load impedance rather than load component, the load current is mainly effected by the magnitude of load impedance rather than load component. Therefore, by treating the load as an impedance, the system's order is reduced and the instantaneous current control using the proposed deadeat controller is simplified.

데드비트 및 디지털 반복제어에 의한 고차 체인드 시스템의 제어 (High order chained system control using deadbeat and iterative control)

  • 남택근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.455-461
    • /
    • 2007
  • In this paper a state steering strategy for high order chained system is presented. High order chained system can be derived from the acceleration constraints that cannot be integrable. The system classified as a nonholonomic system cannot be controlled to its equilibrium points by continuous and time-invariant controller. Using variable transformation two sub system can be obtained from the high order chained system. Deadbeat control and iterative state steering methods are proposed to control the system. Simulation results are given to show the effectiveness of the proposed control scheme.

3상 UPS용 인버터의 강인한 비간섭 디지털제어 (Robust Decoupling Digital Control of Three-Phase Inverter for UPS)

  • 박지호;허태원;신동렬;노태균;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.246-255
    • /
    • 2000
  • This paper deals with a novel full digital control method of the three-phase PWM inverter for UPS. The voltage and current of output filter capacitor as state variables are the feedback control input. In addition, a double deadbeat control consisting of a d-q current minor loop and a d-q voltage major loop, both with precise decoupling, have been developed. The switching pulse width modulation based on SVM is adopted so that the capacitor current should be exactly equal to its reference current. In order to compensate the calculation time delay, the predictive control is achieved by the current·voltage observer. The load prediction is used to compensate the load disturbance by disturbance observer with deadbeat response. The experimental results show that the proposed system offers an output voltage with THD less than 2% at a full nonlinear load.

  • PDF

회전기계 계통을 가동시키는 직류전동기의 데드비트제어시스템 연구 (A Study on Deadbeat Control Systme of DC Motro Driving a Rotational Mechanical System)

  • 송자윤
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 1999년도 추계공동학술대회 논문집:21세기지식경영과 정보기술
    • /
    • pp.477-483
    • /
    • 1999
  • 이 연구는 인쇄기제어와 같은 기어를 포함한 직류전동기로 가동되는 회전계통 플랜트의 제어에 관해서 적분제어기와 전차수 상태관측기 및 영차홀드로 구성되는 데드비트제어시스템을 제안하고 있다. 샘플링된 연속데이터시스템의 응답은 샘플링사이에 리플이 발생치 않도록 보장할 수 없지만, 제안된 데드비트제어시스템의 응답은 MATLAB시뮬레이션을 통한 사례연구의 결과, 상태귀환형 최적제어나 출력귀환형 제어시스템응답 등에 비하여 정정시간이 횔씬 빠르고, 주어진 샘플링주기 후에 리플없는 출력응답을 얻을 수 있음을 보여준다.

  • PDF