• Title/Summary/Keyword: Dead end

Search Result 230, Processing Time 0.022 seconds

Evaluation of flux stabilisation using Bio-UF membrane filter on KZN Rivers, South Africa

  • Thoola, Maipato I.;Rathilal, Sudesh;Pillay, Lingam V.
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.313-325
    • /
    • 2016
  • South Africa recognises piped water as the main source of safe drinking water supply. Remote areas do not have access to this resource and they rely solely on surface water for survival, which exposes them to waterborne diseases. Interim point of use solutions are not practiced due to their laboriousness and alteration of the taste. Bio-ultra low pressure driven membrane system has been noted to be able to produce stable fluxes after one week of operation; however, there is limited literature on South African waters. This study was conducted on three rivers namely; Umgeni, Umbilo and Tugela. Three laboratory systems were setup to evaluate the performance of the technology in terms of producing stable fluxes and water that is compliant with the WHO 2008 drinking water guideline with regards to turbidity, total coliforms and E.coli. The obtained flux rate trends were similar to those noted in literature where they are referred to as stable fluxes. However, when further comparing the obtained fluxes to the normal dead-end filtration curve, it was noted that both the Umbilo and Tugela Rivers responded similarly to a normal dead-end filtration curve. The Umgeni River was noted to produce flux rates which were higher than those obtainable under normal dead-end. It can be concluded that there was no stabilisation of flux noted. However, feed water with low E.coli and turbidity concentrations enhances the flux rates. The technology was noted to produce water of less than 1 NTU and 100% removal efficiency for E.coli and total coliforms.

Performance Degradation of Dead-end Type PEMFC by Startup and Shutdown Cycles (시동/정지 반복에 의한 데드엔드형 고분자전해질 연료전지의 성능 감소)

  • Jeong, Jaehyeun;Jeong, Jaejin;Song, Myunghyun;Chung, Hoibum;Na, Ilchai;Lee, Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.540-544
    • /
    • 2013
  • During start up and shut down of a proton exchange membrane fuel cells (PEMFC), the performance and lifetime of PEMFC were reduced. In this study, effect of startup and shutdown were investigated in dead-end type PEMFC using oxygen as a cathode gas with polarization curve, impedance spectroscopy (EIS), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Dummy load which eliminates residual hydrogen and oxygen during startup and shutdown operation should be applied to mitigated the degradation of PEMFC performance. At 50% relative humidity (RH) under the repetitive on/off cycling, the cell performance decayed faster than at 100% RH because of corrosion of the cathode carbon support. Water suppling into cell reduced the degradation rate of dead-end type PEMFC during start up and shut down cycling at 50% RH.

Analysis of Preconcentration Dynamics inside Dead-end Microchannel (막다른 미세유로 내부의 농축 동역학 분석)

  • Hyomin Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.155-161
    • /
    • 2023
  • Ion concentration polarization (ICP) is one of the essential important mechanisms for biomolecule preconcentration devices as well as a fundamental transport phenomenon found in electrodialysis, electrochemical cell, etc. The ICP triggered by externally applied voltage enables the biomolecular analyte to be preconcentrated at an arbitrary position by a locally amplified electric field inside the microchannel. Conventional preconcentration methodologies using the ICP have two limitations: uncertain equilibrium position and hydrodynamic instability of preconcentration plug. In this work, a new preconcentration method in the dead-end microchannel around cation exchange membrane was numerically studied to resolve the limitations. As a result, the numerical model showed that the analyte was concentrated at a shock front developed in a geometrically confined dead-end channel. Furthermore, the electrokinetic behaviors for preconcentration dynamics were analyzed by changing microchannel's applied voltage and volumetric charge concentration of microchannel as key parameters to describe the dynamics. This work would provide an effective means for a point-of-care platform that requires ultra-fast preconcentration method.

Linear Velocity Control of the Mobile Robot with the Vision System at Corridor Navigation (비전 센서를 갖는 이동 로봇의 복도 주행 시 직진 속도 제어)

  • Kwon, Ji-Wook;Hong, Suk-Kyo;Chwa, Dong-Kyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.9
    • /
    • pp.896-902
    • /
    • 2007
  • This paper proposes a vision-based kinematic control method for mobile robots with camera-on-board. In the previous literature on the control of mobile robots using camera vision information, the forward velocity is set to be a constant, and only the rotational velocity of the robot is controlled. More efficient motion, however, is needed by controlling the forward velocity, depending on the position in the corridor. Thus, both forward and rotational velocities are controlled in the proposed method such that the mobile robots can move faster when the comer of the corridor is far away, and it slows down as it approaches the dead end of the corridor. In this way, the smooth turning motion along the corridor is possible. To this end, visual information using the camera is used to obtain the perspective lines and the distance from the current robot position to the dead end. Then, the vanishing point and the pseudo desired position are obtained, and the forward and rotational velocities are controlled by the LOS(Line Of Sight) guidance law. Both numerical and experimental results are included to demonstrate the validity of the proposed method.

Free Vibrations of Arbitrary Tapered Beams with Static Deflections due to Arbitrary Distributed Dead Loads (임의분포 사하중에 정적변위를 갖는 변단면 보의 자유진동)

  • Lee, Byoung-Koo;Lee, Yong
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.3
    • /
    • pp.50-57
    • /
    • 1996
  • A numerical method is presented to obtain the natural frequencies and mode shapes of the arbitrary tapered beams with static deflection due to arbitrary distributed dead loads. The differential equation governing free vibration of such beams is derived and solved numerically. The double integration method using the trapezoidal rule is used to solve the static behaviour of beams loaded arbitrary distributed dead load. Also, the Improved Euler method and the determinant search method are used to integrate the differential equation subjected to the boundary conditions and to determine the natural frequencies of the beams, respectively. In the numerical examples, the various geometries of the beams are considered : (1) linearly tapered beams as the arbitrary variable cross-section, (2) the triangular, sinusoidal and uniform loads as the arbitrary distributed dead loads and (3) the hinged-hinged, clamped-clamped and hinged-clamped ends as the end constraints. All numerical results are shown as the non-dimensional forms of the system parameters. The lowest three natural frequencies versus load parameter, slenderness ratio and section ratio are reported in figures. And for the comparison purpose, the typical mode shapes with and without the effects of static deflection are presented in the figure. According to the numerical results obtained in this analysis, the following conclusions may be drawn : (1) the natural frequencies increase when the effects of static deflections are included, (2) the effects are larger at the lower modes than the higher ones and (3) it should be betteF to include the effect of static deflection for calculating the frequencies when the beams are supported by both hinged ends or one hinged end.

  • PDF

Study of Design Standard Establishment of Vehicle Rotation Area in the Dead-end Parking Lot (막다른주차장내 차량회전구간 설계기준 정립에 관한 연구)

  • Lim, Jae-Moon;Oh, Se-Kyung;Kim, Hoe-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7403-7415
    • /
    • 2014
  • This study points out a problem that the vehicle rotation area provided in a dead-end parking lot for apartment blocks is misused as unreasonable parking places but accordingly, the edge parking spaces are rarely used for parking. Therefore, this study aims to establish a parking design standard to improve the parking convenience and land-use efficiency by investigating the real parking behaviors and problems identified in the study area, multiple apartment blocks in Haeundae-gu, Busan. This study calculated two simple linear regression models for two mutually exclusive factors, such as the parking convenience and land-use efficiency, respectively, and specified a trade-off point that optimizes both factors. The study results found that parking convenience and land-use efficiency can be improved by not only changing the misused vehicle rotation area to normal parking spaces depending on the usage pattern, but also by increasing the width of the edge parking spaces from 2.3m to 2.6m. Finally, this study suggests two parking design cases for more realistic design applications by considering the parking environment in the dead-end parking lot for apartment blocks.

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (II) : Dead-end Nanofiltration of PCB Etching Waste Solution Containing Copper Ion (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(II) : 구리이온을 함유한 PCB 폐에칭액의 Dead-end 나노여과)

  • Nam, Sang-Won;Jang, Kyung-Sun;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.92-99
    • /
    • 2013
  • In this study the nanofiltration (NF) membrane treatment of a sulfuric acid waste solutions containing copper ion ($Cu^{+2}$) discharging from the etching processes of the printed circuit board (PCB) manufacturing industry has been studied for the recycling of acid etching solution. SelRO MPS-34 4040 NF membrane from Koch company was tested to obtain the basic NF data for recycling of etching solution and separation efficiency (total rejection) of copper ion. NF experiments were carried out with a dead-end membrane filtration laboratory system. The pure water flux was increased with the increasing storage time in sulfuric acid solution and lowering pH of acid solution because of the enhancement of NF membrane damage by sulfuric acid. The permeate flux of acid solution was decreased with the increasing copper ion concentration. Total rejection of copper ion was decreased with the increasing storage time in sulfuric acid solution and copper ion concentration, and lowering the pH of acid solution. The total rejection of copper ion was decreased from initial 37% to 15% minimum value.

Design of Dead-end Membrane Module with Increased Permeate Flux by Natural Convection Instability Flow (자연대류 불안정 흐름에 의해 투과량을 증가시킨 전량여과 막모듈의 설계)

  • Kim, Gi-Jun;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.29 no.3
    • /
    • pp.147-154
    • /
    • 2019
  • The permeate flux increments of a natural convection instability flow (NCIF) caused by the change of inclined angles ($0{\sim}180^{\circ}$) to gravity of the commercial membrane module were tested in the dead-end membrane filtration of BSA protein solution. The NCIF are more generated as the inclined angle increased from $0^{\circ}$ to $180^{\circ}$, and the occurred NCIF enhances permeate flux. However, the commercial module can only generate NCIF by completely removing the air gap in module. Since the custom design module designed in this study is permeated in a crossward direction ($90^{\circ}$), NCIF is always generated even if there is the air gap in module. The results of membrane filtration of BSA and dextran solutions using a custom design module showed that the flux in the crossward direction is increased to about 3.8 times for BSA solution and 1.8 times for dextran solution after two hours of operation due to the occurrence of NCIF. Also, NCIF generation is continued during 20 hours filtration of BSA solution, increasing the permeate flux to about 7.5 times. Since the custom design module with a permeation in the crossward direction and NCIF is always generated within the module, so it is possible to expect an increase in permeate flux due to the suppression of fouling formation, and thus to be utilized as a superb dead-end membrane module.

An Advanced Dead-Time Compensation Method for Dual Inverter with a Floating Capacitor (플로팅 커패시터를 갖는 이중 인버터를 위한 향상된 데드 타임 보상 기법)

  • Kang, Ho Hyun;Jang, Sung-Jin;Lee, Hyung-Woo;Hwang, Jun-Ho;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.271-279
    • /
    • 2022
  • This paper proposes an advanced dead-time compensation method for dual inverter with a floating capacitor. The dual inverter with floating capacitor is composed of double two-level inverters and a bulk electrolytic capacitor. The output voltage of the dual inverter is dropped by the conduction voltage of the power semiconductors. The voltage drop and dead-time cause the fundamental and harmonic distortions of output currents. When supplied power for OEW-load is low, the dual inverter operates as single inverter for effective operation. The dead-time compensation method for the dual inverter operated as single inverter is needed for reliability. The proposed method using band pass filter in this paper compensates dead-time, dead-time error and changed voltage drop error of power semiconductors for the dual inverter and dual inverter operated as single inverter. The effectiveness of the proposed method is verified by simulation results.