• Title/Summary/Keyword: Daylight Responsive Dimming Systems

Search Result 21, Processing Time 0.028 seconds

A optimization of photosensor shape for daylight responsive dimming systems (광센서 조광제어시스템의 효율적인 광센서 형상에 관한 연구)

  • Joo, Keun-Tak;Park, Byeong-Cheol;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.195-199
    • /
    • 2004
  • The most important role of photosensor is to measure on exact workplan illuminance of room when daylight responsive dimming systems are used. The shape of most optimal photosensor must be able to measure exact luminous flux without changing setting position corresponding to the change of room situations. That is, shape and positioning of optimal photosensor should be corresponded to the optimal luminous flux measurement.

  • PDF

A Study on the Characteristics of Daylight Distributions by Different Sky Conditions and Controlled Roller Shade Heights (천공종류 및 롤러쉐이드의 제어된 높이에 따른 주광분포 특성에 관한 연구)

  • Park, Byoung-Chul;Lim, Ji-Sun;Kim, Yu-Sin;Lee, Jeong-Ho;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.18-26
    • /
    • 2009
  • Daylight responsive dimming systems are one of lighting control systems which are to control artificial lightings using available daylight for energy savings. This system is not popular because useful daylight is usually blocked by uncontrolled passive shading systems in buildings. It is necessary to integrate daylight responsive dimming systems and automata! roller shading systems. In this research, mock-up test is performed to analyze the daylight distributions in three different rooms for integrated systems. Roller shades are installed in two rooms. One is fully downed and the other is controlled by sun profile angle. The other room has no shading system as a reference room.

Evaluation on the Characteristics of Daylight Distributions of Grating Louver System in a Pair Glass by Computer Simulation (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.1-9
    • /
    • 2009
  • A recent research trend on the Daylight Responsive Dimming Systems, using available daylight for energy savings, is to integrate automated roller shading systems and venetian blind systems which are vertically controlling daylight to indoor based on sun profile angle. Therefore, this paper suggests Grating Louver System into a pair glass as a new shading system, which can control daylight vertically and horizontally. The optimized spacing of louvers, which is to block direct sunlight into a space, was calculated. And then, the system was simulated for analysis and evaluation of characteristics of daylight by Desktop Radiance 2.0.

An Experimental Study of the Optimum Spatial Characteristics and Location of Photosensor for Daylight Responsive Dimming Systems (광센서 조광제어시스템의 광센서 최적 방향성과 위치에 관한 실험적 연구)

  • 정봉근;최안섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.8-14
    • /
    • 2003
  • The daylight responsive dimming system, which uses daylight and automatically controls the light output of electric lighting according to the amount of 3.vailable daylight, is an energy saving system Successful performance relies on how photosensor signal can precisely represent workplace illuminance. However, it is not accurately identified due to the dynamic nature of the sun and the sky changed with respect to different seasons or time. The purpose of this research is to identify the correlation between workplace illuminance and photosensor signals, and propose an optimal location and spatial characteristics of the photosensor through experiments, which minimizes the above impacts and improve system performance.

A study on daylight distributions for applying effective daylight responsive dimming systems in offices (사무공간에서 효율적인 조광제어시스템 적용을 위한 주광분포 연구)

  • Kim, Ga-Young;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.123-128
    • /
    • 2005
  • This study purposes to increase the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing daylight incident A photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, received a proper dimming signal from DCU. Generally it Is effective to control artificial lighting with the different control ratio of each row by setting a photosensor as same numbers and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. As a result of grasping the distribution of daylight previously, we can dim different dimming ratios to each row of artificial lighting by a single photosensor.

  • PDF

Evaluation of Energy Consumptions in Daylight Responsive Dimming Systems (광센서 조광제어시스템의 소비전력 평가)

  • Lee, Soon-Ji;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.195-199
    • /
    • 2006
  • This study aims to measure amount of the reduction ratio of energy consumptions by the daylight responsive dimming systems, which uses daylighting and electric lighting. The results of this study show that the reduction ratio of electric power is better 'clear sky' by sky condition and 'window side of room' by zoning. When calculating reduction ratio of energy consumptions with used times in real office space, it tells that the result of real office was higher ratio than that of experimental space. For this study which presents efficient use of daylight in office environment, it will be basis of improving energy performance.

  • PDF

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

Characteristics of the Illuminance Distributions by Artificial Lighting in Different Shading Systems (쉐이딩 시스템에 따른 인공조명에 의한 조도분포 특성에 관한 연구)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.169-172
    • /
    • 2009
  • Daylight responsive dimming system, which is one of the method for utilizing available daylight. continuously adjusts lighting output with an algorithm of the correlation of photosensor signal and workplane illuminance levels. This system must be related with shading systems which are to control penetrating daylight. The purpose of this research is to analyze illuminance distributions by artificial lighting in different shading systems. Lighting power is changed by 5 levels in nighttime for comparing correlation between illuminance and lighting power in different shading systems.

  • PDF

A Study on the System Calibration in Daylight Responsive Dimming Systems (광센서 조광제어시스템의 시스템 보정에 관한 연구)

  • 이정은;최안섭;정근영
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.197-201
    • /
    • 2003
  • The purpose of this study is to analyze the slopes of control algorithm and dimming levels based on different inputs and parameters. Different parameters such as photosensor aiming angles, sky types, and seasonal changes were considered. To determine the slopes of control algorithm and dimming levels, photosensor signals and workplan illuminance values were simulated by DayDim program, which is a lighting calculation and analysis tool. A typical small office space was used for simulation and three different sky types in three different seasons were considered. This study shows that differences in dimming levels can occur according to different sky types, if system calibration is conducted in a particular sky type.

  • PDF

Computer Simulation on the Characteristics of Daylight Distributions by Grating Louver System in a Pair Glass (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.117-120
    • /
    • 2009
  • New shading system, which is Grating Louver System into a pair glass, is proposed for integrated lighting system between Daylight Responsive Dimming Systems and shading system in this study. The optimized distance of louvers, which is to block direct sunlight into a space, is calculated. Grating Louver System was simulated using Desktop Radiance 2.0 of lighting simulation software for comparing daylight distribution and changes of control slope by distance from window to back wall with roller shading system controlled by sun profile angle.

  • PDF