• Title/Summary/Keyword: Daylight Distributions

Search Result 19, Processing Time 0.02 seconds

Analysis of Daylight Distributions and Solar Radiation to Verify the Applicability of Blind PV Systems Using Simulation (블라인드PV 시스템의 적용성 검증을 위한 주광 특성 및 일사량 분석 시뮬레이션)

  • Hong, Seong-Kwan;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.1-9
    • /
    • 2011
  • Daylight provides residents with good visual environment. And available daylight in inside provides positive influence on psychological and physiological aspects. Also, sunlight can be converted directly into electricity using PV(photovoltaic) power generation. This study was to analyze characteristics of daylight distributions, calculate an amount of solar radiation and a PV power generation on the building facade using Radiance and Ecotect simulation programs. Ultimately, the purpose of this study is to verify the applicability of Blind PV systems.

Evaluation on the Characteristics of Daylight Distributions of Grating Louver System in a Pair Glass by Computer Simulation (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.1-9
    • /
    • 2009
  • A recent research trend on the Daylight Responsive Dimming Systems, using available daylight for energy savings, is to integrate automated roller shading systems and venetian blind systems which are vertically controlling daylight to indoor based on sun profile angle. Therefore, this paper suggests Grating Louver System into a pair glass as a new shading system, which can control daylight vertically and horizontally. The optimized spacing of louvers, which is to block direct sunlight into a space, was calculated. And then, the system was simulated for analysis and evaluation of characteristics of daylight by Desktop Radiance 2.0.

A Study on the Characteristics of Daylight Distributions by Different Sky Conditions and Controlled Roller Shade Heights (천공종류 및 롤러쉐이드의 제어된 높이에 따른 주광분포 특성에 관한 연구)

  • Park, Byoung-Chul;Lim, Ji-Sun;Kim, Yu-Sin;Lee, Jeong-Ho;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.18-26
    • /
    • 2009
  • Daylight responsive dimming systems are one of lighting control systems which are to control artificial lightings using available daylight for energy savings. This system is not popular because useful daylight is usually blocked by uncontrolled passive shading systems in buildings. It is necessary to integrate daylight responsive dimming systems and automata! roller shading systems. In this research, mock-up test is performed to analyze the daylight distributions in three different rooms for integrated systems. Roller shades are installed in two rooms. One is fully downed and the other is controlled by sun profile angle. The other room has no shading system as a reference room.

Characteristics of the Illuminance Distributions by Artificial Lighting in Different Shading Systems (쉐이딩 시스템에 따른 인공조명에 의한 조도분포 특성에 관한 연구)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.169-172
    • /
    • 2009
  • Daylight responsive dimming system, which is one of the method for utilizing available daylight. continuously adjusts lighting output with an algorithm of the correlation of photosensor signal and workplane illuminance levels. This system must be related with shading systems which are to control penetrating daylight. The purpose of this research is to analyze illuminance distributions by artificial lighting in different shading systems. Lighting power is changed by 5 levels in nighttime for comparing correlation between illuminance and lighting power in different shading systems.

  • PDF

The prediction of reduction ranges of daylight illuminance in small office for sky and shading conditions (천공 및 차양조건에 따른 소규모 사무실의 주광 조도 감소범위 예측)

  • Jang, Seo Yeon
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • This study examines the distributions of daylight illuminance in a small office space under clear and cloudy sky conditions. Three shading conditions using Venetian blinds were applied for the analysis of daylight illuminance. Computer simulations using the Lightscacpe were conducted for the daylight conditions applied to the office space. Results indicate that the illuminance differences between clear and cloudy sky for south-facing conditions were greater than those for north-facing conditions. The differences in December and June were the greatest and smallest, respectively. For the north-facing conditions, the daylight illuminance at 10:00, 12:00 and 14:00 in June and September under the cloudy sky was higher than those under the clear sky conditions. For all daylight conditions, the biggest amount of illuminance reduction occurred when the shading device conditions were changed from the no blind to the 45 degree blinds. As the distance from window increased, the shading effect that occurred when the shading device conditions were changed from the horizontal blind to the 45 degree blinds increased.

A study on daylight distributions for applying effective daylight responsive dimming systems in offices (사무공간에서 효율적인 조광제어시스템 적용을 위한 주광분포 연구)

  • Kim, Ga-Young;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.123-128
    • /
    • 2005
  • This study purposes to increase the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing daylight incident A photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, received a proper dimming signal from DCU. Generally it Is effective to control artificial lighting with the different control ratio of each row by setting a photosensor as same numbers and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. As a result of grasping the distribution of daylight previously, we can dim different dimming ratios to each row of artificial lighting by a single photosensor.

  • PDF

Computer Simulation on the Characteristics of Daylight Distributions by Grating Louver System in a Pair Glass (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.117-120
    • /
    • 2009
  • New shading system, which is Grating Louver System into a pair glass, is proposed for integrated lighting system between Daylight Responsive Dimming Systems and shading system in this study. The optimized distance of louvers, which is to block direct sunlight into a space, is calculated. Grating Louver System was simulated using Desktop Radiance 2.0 of lighting simulation software for comparing daylight distribution and changes of control slope by distance from window to back wall with roller shading system controlled by sun profile angle.

  • PDF

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.

The Image-forming Property of Optical System having Gaussian Amplitude for Polychromatic Source (다색 광원에 대한 가우시안 진폭을 갖는 광학계의 결상 특성)

  • Park, Seong Jong;Park, Hae Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.33-38
    • /
    • 1999
  • To investigate the image-forming property of optical system having Gaussian amplitude for polychromatic source, we calculated the chromaticity variation and the illuminance distribution. Considered polychromatic sources in this paper are A light which is on incandescent-tungsten lamp, C light which is a daylight, and $D_{65}$ light which is a extend daylight to the near ultraviolet. The polychromatic sources represent the different chromaticity values at a geometrical image point. The chromaticity variation of optical system having a Gaussian amplitude is smaller than that having an uniform amplitude. The illuminance distributions for polychromatic sources present nearly the same values, and the depth of focus for optical system having a Gaussian amplitude is wider than that having an uniform amplitude. From these results, we know that the depth of focus increases and the chromaticity variation decreases, when the incident light amplitude is modulated from an uniform amplitude to a Gaussian amplitude.

  • PDF

Proposal of the Prediction Equation for Interior Daylight Illuminance (실내 주광조도 분포 예측식의 제안 및 검증)

  • Park, Woong-Kyu;Park, Tae-Ju;Kang, Gyu-Min;Lee, Sang-Yup;Song, Doosam
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.114-123
    • /
    • 2013
  • In these days, most of the office buildings are being required to save energy for maintenance. lighting system constitutes 20% to 30% of the total annual electrical energy consumption in office buildings. As an energy saving strategy for lighting system, dimming control system based on illuminance sensors came into use. But the system is accompanied with many illuminance sensors to control lighting and needs a lot of initial investment. In this study, the prediction equation for indoor daylighting illuminance distribution is proposed through the review for conventional research results and field measurements. The proposed equation was verified by the comparison between predicted results and field measurement results. The developed prediction equation for daylighting can be used to control the indoor illuminance level with the limited sensor when dimming control system is operated.