• Title/Summary/Keyword: Data glove

Search Result 101, Processing Time 0.027 seconds

A Study on Synthetic Method and Material Analysis of Calcium Ammine Chloride as Ammonia Transport Materials for Solid SCR (Solid SCR용 암모니아 저장물질인 Calcium Ammine Chloride의 합성방법 및 물질분석 연구)

  • Shin, Jong Kook;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.199-207
    • /
    • 2015
  • Solid materials of ammonia sources with SCR have been considered for the application of lean NOx reduction in automobile industry, to overcome complex problems of liquid urea based SCR. These solid materials produce ammonia gas directly with proper heating and can be packaged by compact size, because of high volumetric ammonia density. Among ammonium salts and metal ammine chlorides, calcium ammine chloride was focused on this paper due to low decomposition temperature. In order to make calcium ammine chloride in lab-scale, simple reactor and glove box was designed and built with ammonium gas tank, regulator, and sensors. Basic test conditions of charging ammonia gas to anhydrous calcium chloride are chosen from equilibrium vapor pressure by Van't Hoff plot based on thermodynamic properties of materials. Synthetic method of calcium ammine chloride were studied for different durations, temperatures, and pressures with proper ammonia gas charged, as a respect of ammonia gas adsorption rate(%) from simple weight calculations which were confirmed by IC. Also, lab-made calcium ammine chloride were analyzed by TGA and DSC to clarify decomposition step in the equations of chemical reaction. To understand material characteristics for lab-made calcium ammine chloride, DA, XRD and FT-IR analysis were performed with published data of literature. From analytical results, water content in lab-made calcium ammine chloride can be discovered and new test procedures of water removal were proposed.

The Influence of Cold Therapy on the Perineal Discomfort and the Healing State of the Postpartum Women (냉요법이 산모의 회음부 불편감 및 치유상태에 미치는 영향)

  • Shin, Hyun-Jeong
    • Women's Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.67-83
    • /
    • 1998
  • A quasi-experiment, repeated measures design with non-equivalent control group was used to test the influence of cold therapy on the perineal discomfort and the healing state of the postpartum women undergoing vaginal delivery with episiotomy. Experiment was carried out from July 28, through October 2, 1996 with 40 postpartum women conveniently sampled from one university hospital located in Seoul. The 40 postpartum women undergoing vaginal delivery with episiotomy were as signed to experimental and control groups evenly(20 each). The instrument of measurement of perineal discomfort was 0-10 rating scale that was made by researcher and that of perineal healing state was Davidson's REEDA tool. The perineal discomfort and the healing state level were measured before and after each treatment. The treatment using ice glove that was given for the only experimental group was carried out at three points ; as soon as returning to the recovery room, 3 hours after returning to the recovery room and 6 hours after returning to the recovery room. The data was analysed by using t-test, chi-square test to determine the similarity between experimental and control groups. The hypotheses were tested using repeated measures ANOVA. The results of this study are summarized as follows; 1. The first hypothesis that the perineal discomfort level of the experimental group will be significantly lower than that of the control group(df(1,38), F=24.12, p=.0001) was supported. 2. The second hypothesis that the perineal healing state of the experimental group wil be better than that of the control group(df(1,38), F=0.48, p=.49) was not supported. Based on the results of this study, could therapy was turned out to have significant effect on the perineal discomfort of the postpartum women undergoing vaginal delivery with episiotomy.

  • PDF

The Coating Effects of Al2O3 on a Li[Li0.2Mn0.54Co0.13Ni0.13]O2 Surface Modified with (NH4)2SO4

  • Oh, Ji-Woo;Oh, Rye-Gyeong;Hong, Jung-Eui;Yang, Won-Geun;Ryu, Kwang-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1516-1522
    • /
    • 2014
  • A series of 20 wt % $(NH_4)_2SO_4$ and 3 wt % $Al_2O_3$ surface treatments were applied to $Li[Li_{0.2}Mn_{0.54}Co_{0.13}Ni_{0.13}]O_2$ substrates. The $Li[Li_{0.2}Mn_{0.54}Co_{0.13}Ni_{0.13}]O_2$ substrates were synthesized using a co-precipitation method. Sample (a) was left pristine and variations of the 20 wt % $(NH_4)_2SO_4$ and 3 wt % $Al_2O_3$ were applied to samples (b), (c) and (d). XRD was used to verify the space group of the samples as R$\bar{3}$m. Additional morphology and particle size data were obtained using SEM imagery. The $Al_2O_3$ coating layers of sample (b) and (d) were confirmed by TEM images and EDS mapping of the SEM images. 2032-type coin cells were fabricated in a glove box in order to investigate their electrochemical properties. The cells were charged and discharged at room temperature ($25^{\circ}C$) between 2.0V and 4.8V during the first cycle. The cells were then charged and discharged between 2.0V and 4.6V in subsequent cycles. Sample (d) exhibited lower irreversible capacity loss (ICL) in the first charge-discharge cycle as compared to sample (c). Sample (d) also had a higher discharge capacity of ~250 mAh/g during the first and second charge-discharge cycles when compared with sample (c). The rate capability of the $Al_2O_3$-coated sample (b) and (d) was lower when compared with sample (a) and (c). Sample (d), coated with $Al_2O_3$ after the surface treatment with $(NH_4)_2SO_4$, showed an improvement in cycle performance as well as an enhancement of discharge capacity. The thermal stability of sample (d) was higher than that of the sample (c) as the result of DSC.

Assessment of Vibration Produced by Pneumatic Hand Tools Used in Automobile Assembly (자동차 조립공정에서 공기압력식 진동공구의 국소진동평가)

  • Kim, Sun Sul;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • This study was conducted at an automobile assembly line located in Kyonggi-do, Korea from January 16 to February 28, 1995. The purposes of this study were to assess worker exposures to hand-arm vibration and the performance of gloves for reduction of vibration. The exposure to vibration was measured using to the ISO 5349(1986) method. Vibration acceleration and frequency spectra for each tool were determined on-line replicating actual working conditions and analyzed together with exposure time for evaluating individual worker exposure. Eight pneumatic hand tools, 60 workers exposured to hand-arm vibration, and three pairs of gloves were involved in this study. Results are summarized as follows. 1. Dominant frequencies of vibration for all tools(n=8) measured in this study ranged from 250 Hz to 800 Hz. 2. There was no significant correleration between dominant frequencies and free running speed (p>0.05). 3. Total predicted exposure times of using impact, hammer type did not exceed 40 minutes, but metal finish task, using grinder and sander exceeded 40 minutes. Total exposure time affected significantly the frequency-weighted, 4 hr equivalent acceleration. 4. Predicted prevalence and observed exposure period data were compared in workers(n=60), according to ISO 5349. In this results, 23(50.0 %) and 24(48.07 %) persons exceeded the mean latency periods for vibration-induced white finger(VWF) at 10 % (n=46) and 50 % (n=52) standards, respectively. On the basis of ISO equation, mean latent periods for VWF were 3.23, 4.72 years at 10 %, 50 % standards, respectively. 5. Reduction of vibration by gloves was evaluated. Since impact pneumatic tools produced low frequency vibrations, conventional gloves did not provide any protection. Gloves A and C amplify somewhat the signal at frequency below 400 Hz; the attenuation increases progressively by frequency to reach 18 dB ($7.94{\times}10^{-6}m/s^2$) at 1,000 Hz, slightly worsening Glove B did not provide any protection and made the situation slightly worse. However, since they make the hands warm, the occurrence of vibration-induced white fingers may be reduced.

  • PDF

Augmented Reality Board Game System and PGA (실감형 보드게임 시스템과 PGA)

  • Han, Eun-Jung;Kim, Ki-Rack;Lee, Jang-Hyung;Yoo, Chang-Hyuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.1
    • /
    • pp.163-173
    • /
    • 2011
  • In this paper, we propose a new paradigm of augmented reality board game environment and a portable game assistant(PGA) which can help gamers with strategy information. Previous AR board games consist of a private and public space. The public space provides rules of the game and shows the scene of game. And the gamers control game pieces in the public space. The previous games use the RFIDs for recognizing positions of the pieces, and the VR/AR environment for providing the scene of the game. However the RFIDs are expansive, and the VR/AR environment is inconvenient because it uses additional devices: the DataGlove, the digital pen, and the HMD. The proposed system recognizes positions of real pieces using the computer vision technique, and uses a monitor to provide dynamic effects. In the private space, previous systems provide entire screen of game and position of specific pieces, but cannot be controled the pieces by gamers. Therefore, in this system, we provide PGA that helps the user to plan of the strategy individually using universally mobile. The PGA helps to plan the strategy in the individual area, and to play easily in the side of the user's convenience.

Development of Wrist Tunnel Syndrome Prevention Smart Gloves using CNT-based Tensile Fabric Sensor: Focusing on Mouse Use (CNT 기반의 인장 직물 센서를 사용한 손목터널증후군 예방 스마트장갑 개발: 마우스사용을 중심으로)

  • Chun, Se-Hwan;Kim, Sang-Un;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.117-128
    • /
    • 2021
  • In this work, we study smart gloves that can prevent carpal tunnel syndrome when using a mouse. Because the left and right wrist movements are fine, a tensile fabric sensor with a large gauge factor and low hysteresis was required before the study. A universal testing machine was used to calculate each gauge rate on four different fabrics, and the fabric with the least hysteresis was selected. In addition, three attachment methods were analyzed using Arduino to select a method with a large sensor value change. For prototypes made by attaching to the selected fabric, data patterns were analyzed using Arduino. The first method identifies only one sensor (A sensor), and the second identifies two sensors (A and B sensors). When the wrist is bent to the right, tensile fabric sensors are attached to both the left (A sensor) and right (B sensor) sides of the wrist, the A sensor is strained, increasing the △sensor value, and the B sensor is relaxed, decreasing the △sensor value. However, when the wrist was bent to the left, the pattern was analyzed in the opposite direction. Through this study, we examined smart gloves to prevent carpal tunnel syndrome with an algorithm that turns on the LED when the wrist is bent, and based on the results of this study, we will directly use mice on 10 people to identify problems and solve problems when used.

An Implementation of Dynamic Gesture Recognizer Based on WPS and Data Glove (WPS와 장갑 장치 기반의 동적 제스처 인식기의 구현)

  • Kim, Jung-Hyun;Roh, Yong-Wan;Hong, Kwang-Seok
    • The KIPS Transactions:PartB
    • /
    • v.13B no.5 s.108
    • /
    • pp.561-568
    • /
    • 2006
  • WPS(Wearable Personal Station) for next generation PC can define as a core terminal of 'Ubiquitous Computing' that include information processing and network function and overcome spatial limitation in acquisition of new information. As a way to acquire significant dynamic gesture data of user from haptic devices, traditional gesture recognizer based on desktop-PC using wire communication module has several restrictions such as conditionality on space, complexity between transmission mediums(cable elements), limitation of motion and incommodiousness on use. Accordingly, in this paper, in order to overcome these problems, we implement hand gesture recognition system using fuzzy algorithm and neural network for Post PC(the embedded-ubiquitous environment using blue-tooth module and WPS). Also, we propose most efficient and reasonable hand gesture recognition interface for Post PC through evaluation and analysis of performance about each gesture recognition system. The proposed gesture recognition system consists of three modules: 1) gesture input module that processes motion of dynamic hand to input data 2) Relational Database Management System(hereafter, RDBMS) module to segment significant gestures from input data and 3) 2 each different recognition modulo: fuzzy max-min and neural network recognition module to recognize significant gesture of continuous / dynamic gestures. Experimental result shows the average recognition rate of 98.8% in fuzzy min-nin module and 96.7% in neural network recognition module about significantly dynamic gestures.

A Study on Practice of Infection Control by Dental Hygienists -With Reference to Seoul and Incheon·Gyeonggi Province- (치과위생사의 감염방지 실천 정도에 관한 연구 - 서울 및 인천·경기도를 중심으로-)

  • Park, Hyang-Sook;Choi, Jung-Young;Sim, Su-Hyun;Kim, Jin-Soo;Choi, Boo-Keun;Jang, Hee-Kyung
    • Journal of dental hygiene science
    • /
    • v.8 no.4
    • /
    • pp.275-281
    • /
    • 2008
  • Background: This research aims to provide basic data for dental hygienists to implement the infection control after understanding the level of their implementation of infection control in case they have been trained of infection control or not. Method: The respondents in this research are the dental hygienists who worked in the Incheon or Gyeonggi areas between June 16 and July 5, 2008 and who attended complementary training conducted by the Seoul Branch of Korean Dental Hygienists Association in April 2008. A total of 191 questionnaires were distributed to them, and the frequency of the collected data was analyzed using SPSS WIN 12.0. Moreover, cross-tabulation analysis (${\chi}^2$) whose significance level was 0.05, was applied to the data in order to verify the statistical significance of the survey method. Result: There was significant difference in their practice to wear gloves and/or a mask, use a disposable apron and the time to change the apron depending upon the respondents' workplace. There was significant difference in the time to change their apron depending upon the respondents' time of service. 91.6% had been trained in the infection control: of them, 70.7% trained at their school. It was found that 68.6% of the respondents who had been trained in the infection control would wash their hands before treating a patient. 50.3% of the respondents who had been trained in the prevention of contamination would wear their gloves as needed for a basic treatment. Conclusion: Considering the above results of this research, it is concluded that it is necessary to provide practicing dental hygienists with many opportunities for systematic and practical training so that they may faithfully follow the guidelines for the prevention of contamination and to encourage hospitals to have a greater store of relevant facilities, equipment and supplies.

  • PDF

Investigation of Infection Prevention by Dental Hygienist's Personal Protection (치과위생사의 개인방호에 관한 감염방지 실태조사)

  • Kim, Chang-Hee;Jang, Hee-Kyung
    • Journal of dental hygiene science
    • /
    • v.5 no.2
    • /
    • pp.63-70
    • /
    • 2005
  • The relation among the variables of dental hygienists' both personal protection and infection prevention education was investigated in order to identify the necessity of realization of personal protection and utilize in the development of educational programs. The study tools included structured questionnaire and in-home interview. Data analysis included frequency and t-test, and the relations among the variables were as below: (1) Dental hygienist's maskwearing was most well observed in Kyonggi-do (90.0%) by locations, and in the dental hospitals (84.8%) by working places, which was statistically significant. (2) Glove-wearing was most well observed in the university and the higher graduates population (59.1%) by academic background, and in the dental hospital (73.9%) by working place, which was statistically significant. (3) Protection glasses-wearing was most well observed in Guns, Ups, and Myons (82.4%) by locations, which was statistically significant. (4) Uniforms were hand-laundered at home in the 40.9% of the university and the higher graduates, which was statistically significant. (5) About infection management, 67.0% of 2-year college graduates and 71.7% of the respondents from dental hospitals had been educated during their college days, which was statistically significant. (6) About the necessity of infection education, 77.3% of the university graduates responded it is very necessary, which was statistically significant.

  • PDF

Hazard Analysis for the Cultivation Stage of Strawberry Farms for Securing Preliminary Data to Establish the Good Agricultural Practices (농산물우수관리제도 확립의 기초자료 확보를 위한 딸기농장 재배단계의 위해요소 분석)

  • Lee, Chi-Yeop;Lee, Won-Gyeong;Song, Jeong-Eon;Kim, Kyeong-Yeol;Shim, Won-Bo;Yoon, Yo-Han;Kim, Yun-Shik;Chung, Duck-Hwa
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.97-108
    • /
    • 2012
  • Physical, chemical and biological hazards of strawberry farms at the cultivation stage were analyzed to establish the GAP(Good Agricultural Practice) system. Samples were collected from the plants, cultivation environments(water, soil and air), and personal hygiene (hand, glove, and clothes) of three strawberry farms(A, B, and C) and were tested to analyze physical, chemical (heavy metals and pesticide residues), and biological(sanitary indications and foodborne pathogens) hazards. Physical hazards such as insects and pieces of metal and glass were found in the strawberry farms and can be potential bow for strawberry products. Heavy metal and pesticide residue as chemical hazards were detected at levels lower than the regulation limit. In case of biological hazards, total bacteria and coliform were detected at the levels of 1.6~7.3 and 1.3~5.6 log CFU/g, leaf, mL, hand or $100cm^2$. However, Escherichia coli was not detected in all samples. Bacillus cereus and Staphylococuus aureus were detected at levels of ${\leq}$ 1.1~6.1 log CFU and 4.7~5.4 log CFU/g, mL, hand or $100cm^2$, whereas Listeria monocytogenes, E. coli O157 and Salmonella spp. were not detected in all samples. This study demonstrates that various harzards were in strawberry farms at the growing stage. Therefore proper management such as GAP is needed to prevent the occurrence of food poisoning associated with the hazards revealed in this study.