• Title/Summary/Keyword: Data Retention Time

Search Result 232, Processing Time 0.025 seconds

A simplified directly determination of soil-water retention curve from pore size distribution

  • Niu, Geng;Shao, Longtan;Sun, De'an;Guo, Xiaoxia
    • Geomechanics and Engineering
    • /
    • v.20 no.5
    • /
    • pp.411-420
    • /
    • 2020
  • Numbers fitting-curve equations have been proposed to predict soil-water retention curve (SWRC) whose parameters have no definitude physical meaning. And these methods with precondition of measuring SWRC data is time-consuming. A simplified directly method to estimate SWRC without parameters obtained by fitting-curve is proposed. Firstly, the total SWRC can be discretized into linear segments respectively. Every segment can be represented by linear formulation and every turning point can be determined by the pore-size distribution (PSD) of Mercury Intrusion Porosimetry (MIP) tests. The pore diameters governing the air-entry condition (AEC) and residual condition (RC) can be determined by the PSDs of MIP test. The PSD changes significantly during drying in SWR test, so the determination of AEC and RC should use the PSD under corresponding suction conditions. Every parameter in proposed equations can be determined directly by PSD without curve-fitting procedure and has definitude physical meaning. The proposed equations give a good estimation of both unimodal and bimodal SWRCs.

Application of Probabilistic Health Risk Analysis in Life Cycle Assessment -Part I : Life Cycle Assessment for Environmental Load of Chemical Products using Probabilistic Health Risk Analysis : A Case Study (전과정평가에 있어 확률론적 건강영향분석기법 적용 -Part II : 화학제품의 환경부하 전과정평가에 있어 건강영향분석 모의사례연구)

  • Park, Jae-Sung;Choi, Kwang-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.203-214
    • /
    • 2000
  • Health risk assessment is applied to streamlining LCA(Life Cycle Assessment) using Monte carlo simulation for probabilistic/stochastic exposure and risk distribution analysis caused by data variability and uncertainty. A case study was carried out to find benefits of this application. BTC(Benzene, Trichloroethylene, Carbon tetrachloride mixture alias) personal exposure cases were assumed as production worker(in workplace), manager(in office) and business man(outdoor). These cases were different from occupational retention time and exposure concentration for BTC consumption pattern. The result of cancer risk in these 3 scenario cases were estimated as $1.72E-4{\pm}1.2E+0$(production worker; case A), $9.62E-5{\pm}1.44E-5$(manger; case B), $6.90E-5{\pm}1.16E+0$(business man; case C), respectively. Portions of over acceptable risk 1.00E-4(assumed standard) were 99.85%, 38.89% and 0.61%, respectively. Estimated BTC risk was log-normal pattern, but some of distributions did not have any formal patterns. Except first impact factor(BTC emission quantity), sensitivity analysis showed that main effective factor was retention time in their occupational exposure sites. This case study is a good example to cover that LCA with probabilistic risk analysis tool can supply various significant information such as statistical distribution including personal/environmental exposure level, daily time activity pattern and individual susceptibility. Further research is needed for investigating real data of these input variables and personal exposure concentration and application of this study methodology.

  • PDF

CMOS On-Chip Temperature detector circuit For Low Power DRAM (저전력 DRAM을 위한 온-칩 온도 감지 회로)

  • Kim, Young-Sik;Lee, Jong-Seok;Yang, Ji-Un;Lee, Hyun-Seok;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.232-234
    • /
    • 1996
  • The self-refresh mode was introduced as method to reduce power dissipation in DRAM. Because the data retention time of DRAM cell decreases as the ambient temperature rises, the internal period in self-refresh mode must be limited by retention capability at the highest temperature in DRAM specification. Because of this, at room temperature($25^{\circ}C$) unnecessary power dissipation happens, If the period of self-refresh could be modulated as temperature, it is possible to reduce the self-refresh current. In this paper, new temperature detector circuit is suggested as this purpose.

  • PDF

Adsorption Kinetics for Polymeric Additives in Papermaking Aqueous Fibrous Media by UV Spectroscopic Analysis

  • Yoon, Sung-Hoon;Chai, Xin-Sheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1819-1824
    • /
    • 2006
  • The general objective of the present study was to investigate the potential application of the UV spectroscopic method for determination of the polymeric additives present in papermaking fibrous stock solutions. The study also intended to establish the surface-chemical retention model associated with the adsorption kinetics of additives on fiber surfaces. Polyamide epichlorohydrin (PAE) wet strength resin and imidazolinium quaternary (IZQ) softening agents were selected to evaluate the analytical method. Concentrations of PAE and IZQ in solution were proportional to the UV absorption at 314 and 400 nm, respectively. The time-dependent behavior of polymeric additives obeyed a mono-molecular layer adsorption as characterized in Langmuir-type expression. The kinetic modeling for polymeric adsorption on fiber surfaces was based on a concept that polymeric adsorption on fiber surfaces has two distinguishable stages including initial dynamic adsorption phase and the final near-equilibrium state. The simulation model predicted not only the real-time additive adsorption behavior for polymeric additives at high accuracy once the kinetic parameters were determined, but showed a good agreement with the experimental data. The spectroscopic method examined on the PAE and IZQ adsorption study could potentially be considered as an effective tool for the wet-end retention control as applied to the paper industry.

Analysis of Regional Antecedent Wetness Conditions Using Remotely Sensed Soil Moisture and Point Scale Rainfall Data (위성토양수분과 지점강우량을 이용한 지역 선행습윤조건 분석)

  • Sunwoo, Wooyeon;Kim, Daeun;Hwang, Seokhwan;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2014
  • Soil moisture is one of the most important interests in hydrological response and the interaction between the land surface and atmosphere. Estimation of Antecedent Wetness Conditions (AWC) which is soil moisture condition prior to a rainfall in the basin should be considered for rainfall-runoff prediction. In this study, Soil Wetness Index (SWI), Antecedent Precipitation Index ($API_5$), remotely sensed Soil Moisture ($SM_{rs}$), and 5 days ground Soil Moisture ($SM_{g5}$) were selected to estimate the AWC at four study area in the Korean Peninsula. The remotely sensed soil moisture data were taken from the AMSR-E soil moisture archive. The maximum potential retention ($S_{obs}$) was obtained from direct runoff and rainfall using Soil Conservation Service-Curve Number (SCS-CN) method by rainfall data of 2011 for each study area. Results showed the great correlations between the maximum potential retention and SWI with a mean correlation coefficient which is equal to -0.73. The results of time length representing the time scale of soil moisture showed a gap from region to region. It was due to the differences of soil types and the characteristics of study area. Since the remotely sensed soil moisture has been proved as reasonable hydrological variables to predict a wetness in the basin, it should be continuously monitored.

Continuity of BLS Training Effects in Nursing Students (간호대학생의 기본심폐소생술에 대한 교육효과의 지속성)

  • Kim, Hye-Sook;Choi, Eun-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.18 no.1
    • /
    • pp.102-110
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the effects of BLS training in nursing students and their retention period. Methods: The participants were 48 nursing students enrolled in M University in Mokpo. Data were collected from September, 2009 through September 2010. Nursing students were tested for their knowledge, attitude, confidence before, immediately after, 4 weeks after, 8 weeks after, 6 months after, and 1 year after BLS training. In addition, their knowledge and skill of cardiopulmonary resuscitation were tested 5 times. Data were analyzed using the SPSS/PC 12.0 statistical program Results: Knowledge, attitude and confidence were significantly increased immediately after compared to before BLS training. Knowledge and confidence 6 months after, and attitude, performance ability and technical precision for ventilation and compression 4 weeks after BLS training were significantly decreased compared to immediately after. Conclusion: Overall retention of BLS training effects among nursing students, without reinforcement, decreases significantly after six months following initial training. BLS training in nursing students should be repeated every six months, especially performance training of BLS should be repeated every 4 weeks. In addition, to maintain the knowledge and skills of BLS, appropriate renewal time of certification and improvement of training programs are necessary.

Study on The System Suitability Test for Alcohols Separation by GCOTC (GCOTC에 의한 알코올류 분리를 위한 시스템 적합성에 관한 연구)

  • Oh, Doe Seok;Kim, Sung Hwa;Lee, Seul;Choi, Jae Gu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2017
  • Objectives: The purpose of this study is to enhance the application of analytical method of polar solvents(alcohols) by GCOTC (gas chromatography open tubular column) through the system suitability test(SST) to estimate the whole chromatographic system performance(integral part). Methods: To perform the SST, carried out repeatability(n=6) as analytical method of polar solvents by GCOTC, got the retention time($t_R$), standard deviation(${\sigma}_{n-1}$) of $t_R$, baseline width($w_b=4{\sigma}_{n-1}$) and calculated dead time($t_m$) by $v_m=d^2{\pi}L(f/4)$ and $v_m=t_m$ x flow rate. Results: In this experiment, obtained the basic data, there were $t_m=2$ min, methanol($t_R=3.569$, ${\sigma}_{n-1}=0.01$, $w_b=0.04$), ethanol ($t_R=3.892$, ${\sigma}_{n-1}=0.004$, $w_b=0.016$), isopropanol($t_R=4.209$, ${\sigma}_{n-1}=0.004$, $w_b=0.016$). By using these data, calculated the corrected retention time($t_R{^{\prime}}$), capacity factor(k), separation factor(${\alpha}$), number of theoretical plate(n) and resolution($R_s$) for SST and got the good results. Conclusions: Through the SST, could reconfirm the whole chromatographic performance system(integral part) for analytical method of polar solvents by GCOTC. Therefore, this analytical method expect to be widely applied at the related areas.

Identification of Pitfalls Related to the Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Time of Flight Mass Spectrometry (액체크로마토그래프-질량분석기를 이용한 정성 및 정량 오류의 확인)

  • Kwon, Jin-Wook;Cho, Yoon-Jae;Rhee, Gyu-Seek
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.3
    • /
    • pp.230-237
    • /
    • 2015
  • BACKGROUND: To identify the sources of inaccuracy in LC/MS/MS methods used in the routine quantitation of small molecules are described and discussed. METHODS AND RESULTS: Various UPLC coupled to triple quadrupole mass spectrometer and time of flight (TOF) were used to identify the potential sources of inaccuracy and inducing the pitfalls of qualification and quntitation during the veterinary drug residue analysis. Some of stable isotope labelled veterinary drugs, which were used as internal standards, presented "cross-talk", regardless of manufactures of mass spectrometer and types of spectrometer. Group of sulfonamides also presented inaccuracy qualification and quantitation due to the multi-residue analytical method with the same fragment ions at the close retention times. CONCLUSION: The phenomena of "cross-talk" occurring between subsequently monitored transition from stable isotope labelled and isotope non-labelled authentic chemical were identified. To prevent errors and achieve more accurate data during the analysis of small molecules by LC/MS/MS SRM method, Followings should be taken care of and kept checking; purity and concentration of stable isotope as an internal standard, prevention of carry-over during the separation in column, minimizing the ion suppression by matrix effect, identification of retention time, precursor ion and product ion, and full knowledge of data processing including smoothing and peak integration.

A study on the Trap Density of Silicon Oxide (실리콘 산화막의 트랩 밀도에 관한 연구)

  • 김동진;강창수
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.13-18
    • /
    • 1999
  • The trap density by the stress bias in silicon oxides with different thicknesses has been investigated. The trap density by stress bias was shown to be composed of on time current and off time current. The on time trap density was composed of dc current. The off time trap density was caused by the tunneling charging and discharging of the trap in the interfaces. The on time trap density was used to estimate to the limitations on oxide thicknesses. The off time trap density was used to estimate the data retention in nonvolatile memory devices.

  • PDF

Simultaneous Analysis of Stimulants and Narcotic Analgesics by Capillary Column Gas Chromatography with Nitrogen Phosphorus Detector (Capillary Column Gas Chromatography/Nitrogen Phosphorus Detector를 이용한 흥분제 및 마약성 진통제의 동시분석에 관한 연구)

  • Lho, Dong-Seok;Shin, Ho-Sang;Kang, Bo-Kyung;Paek, Heang-Kee;Kim, Seung-Ki;Lee, Jeong-Ae;Kim, Young-Lim;Park, Jong-Sei
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.659-666
    • /
    • 1991
  • A systematic analysis of 18 stimulants and narcotic analgesics containing nitrogen atom (s) in human urine by gas chromatography with nitrogen phosphorus detector (GC-NPD), is described. The urinary extract with diethyl ether at pH 8.5 showed good recoveries of the drugs and less interference peaks on GC chromatogram. Retention data were standardized by the calculation of relative retention times using diphenylamine as the internal standard. The relative standard deviations of retention times were less than 0.1% for the within-run analyses. The response factor (RRF) of a drug relative to the internal standard was calculated. RRF decreased with increasing number of nitrogen atoms. This technique can be adapted to various analytical toxicology problems.

  • PDF