• 제목/요약/키워드: Data Retention Time

검색결과 231건 처리시간 0.027초

MEDICI 시뮬레이터를 이용한 DRAM의 Refresh 시간 개선에 관한 연구 (A Study on Refresh Time Improvement of DRAM using the MEDICI Simulator)

  • 이용희;이천희
    • 한국시뮬레이션학회논문지
    • /
    • 제9권4호
    • /
    • pp.51-58
    • /
    • 2000
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. The novel junction process scheme in sub-micron DRAM cell with STI(Shallow Trench Isolation) has been investigated to improve the tail component in the retention time distribution which is of great importance in DRAM characteristics. In this' paper, we propose the new implantation scheme by gate-related ion beam shadowing effect and buffer-enhanced ${\Delta}Rp$ (projected standard deviation) increase using buffered N-implantation with tilt and 4X(4 times)-rotation that is designed on the basis of the local-field-enhancement model of the tail component. We report an excellent tail improvement of the retention time distribution attributed to the reduction of electric field across the cell junction due to the redistribution of N-concentration which is Intentionally caused by ion Beam Shadowing and Buffering Effect using tilt implantation with 4X-rotation. And also, we suggest the least requirements for adoption of this new implantation scheme and the method to optimize the key parameters such as tilt angle, rotation number, Rp compensation and Nd/Na ratio. We used MEDICI Simulator to confirm the junction device characteristics. And measured the refresh time using the ADVAN Probe tester.

  • PDF

Membrane fouling in thermophilic membrane bioreactor with different sludge retention times

  • Ince, Elif;Ince, Mahir;Topaloglu, Alikemal
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.343-351
    • /
    • 2018
  • As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention time increases, membrane fouling rate decreases.

중학생들의 수학과 평가 결과의 파지 유형 분석 (Analysis of Middle School Students' Retention Types about Results of Evaluation in School Mathematics)

  • 김민주;강윤수
    • 한국수학교육학회지시리즈E:수학교육논문집
    • /
    • 제21권2호
    • /
    • pp.331-345
    • /
    • 2007
  • 본 연구에서는 중학생들이 수학 평가 결과를 어떻게 파지하는지를 탐구하고자 하였다. 이를 위해, 측정시기, 문항 유형, 성적, 평가요소 등을 학생들이 평가결과를 파지하는데 중요한 요인이라고 보고 이 변인들과 관련된 학생들의 평가결과 파지 유형을 분류하였다. 이를 토대로, 두 명의 연구 참여자를 선정하여 심층면담을 진행함으로써 그들의 평가에서 핵심적인 역할을 하는 요소가 무엇이며 그것이 향후에 어떤 형태로 파지되어 나타나는지를 분석함으로써 중학생들의 수학과 평가 결과의 파지 유형을 분석하였다.

  • PDF

Retention Characteristics of Various Proteins in Flow Field-Flow Fractionation : Effects of pH, Ionic Strength, and Denaturation

  • 송종희;김원숙;박영훈;유의경;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권10호
    • /
    • pp.1159-1164
    • /
    • 1999
  • The study investigated the effect of carrier composition (ionic strength and pH) on the retention of various proteins in flow field-flow fractionation (Flow FFF) as well as the conformational change of Bovine Serum Albumin (BSA) with urea concentration, storage time and temperature. The study found that the retention of protein in Flow FFF increased with the ionic strength of the carrier liquid. Most proteins were well solubilized at pH = 7-8. The hydrodynamic diameters obtained from Flow FFF retention data agree well with theoretical values. The retention increased and the peak shape became distorted at extreme pH conditions of the carrier solution. The selected carrier composition for comparison between the literature value of proteins was 0.05 M tris buffer solution with a pH of 8. Storing BSA at 4 ±2℃ over a period of three months resulted in slow dimerization. Also, in case of the storage of BSA at 37 ±5℃ for one week, the retention of both BSA monomer and dimer increased with the urea concentration. Finally, the structural composition of specific enzymes: malonyl-CoA decarboxylase (MCDC) and malonyl-CoA synthesis (MCS) was determined by using Flow FFF at specific carrier solutions. The molecular weight of the natural MCDC was determined to be 208 kDa, which means it is a homotetramer, while that of the MCS was determined to be 47 kDa, which means it is a monomer.

GC/MS분석자료의 목표물질 인식에 관한 연구 (A Study on the Identification of Target Compounds From the GC/MS Data)

  • 민홍기;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.223-228
    • /
    • 1989
  • In this paper, the computerized interpretation of the analytical chemical data, especially GC/MS data, was performed for the purpose of prescreening of the target compounds. First, the data from the analytical instrument was analyzed to get the information about the retention time of the ISTD and the time inteval between the records. Second, the identification of the characteristic ion peaks was performed by calculating the ratio of the heights and the relative slope sensitivity of the characteristic mass abundance.

  • PDF

Dynamic Customer Population Management Model at Aggregate Level

  • Kim, Geon-Ha
    • Management Science and Financial Engineering
    • /
    • 제16권3호
    • /
    • pp.49-70
    • /
    • 2010
  • Customer population management models can be classified into three categories: the first category includes the models that analyze the customer population at cohort level; the second one deals with the customer population at aggregate level; the third one has interest in the interactions among the customer populations in the competitive market. Our study proposes a model that can analyze the dynamics of customer population in consumer-durables market at aggregate level. The dynamics of customer population includes the retention curves from the purchase or at a specific duration time, the duration time expectancy at a specific duration time, and customer population growth or decline including net replacement rate, intrinsic rate of increase, and the generation time of customer population. For this study, we adopt mathematical ecology models, redefine them, and restructure interdisciplinary models to analyze the dynamics of customer population at aggregate level. We use the data of previous research on dynamic customer population management at cohort level to compare its results with those of ours and to demonstrate the useful analytical effects which the precious research cannot provide for marketers.

고성능 이온 크로마토그래피에서 유기산의 크로마토그램 예측 연구 (Prediction of Organic Acid Chromatogram in High Performance Ion Chromatography)

  • 원혜진;한선호;박양순;조기수;김인호
    • KSBB Journal
    • /
    • 제15권1호
    • /
    • pp.60-65
    • /
    • 2000
  • 크로마토그래피의 거동을 수치 모사하기 위하여, retention time method와 moment method에 의해 계산된 파라미터들을 흡착 등온선 모델식에 사용하였다. 이 경우, 이론치와 비교하기 위해서 등용매 조건하게 유기산 이온 크로마토그래피 실험을 수행하였고, 크로마토그램의 거동을 설명하는 수학적 모델로 equilibrium-dispersive model을 사용하였다. Moment method에서는 평균체류시간을 나타내는 1차 모멘트, $m^2$1와 분배 계수 K의 관계로 나타낼 수 있으며, 실험을 통해 분배 계수는 쉽게 구해 질 수 있다. 운전 변수의 변화에 따른 크로마토그램의 특성을 살펴보기 위해서 유기산의 농도, 이동상의 유속, 용리액의 이온 강도 그리고 용질의 주입량을 변화시켜 수치모사를 수행하였다. 각각의 조건에 대해서 크로마토그램은 용질의 농도가 증가할수록, 유속이 증가할수록, 이온 강도가 증가할수록 평균 체류 시간이 감소하고 날카로운 피크를 얻을 수 있었으며, retention time method에서 보다 moment method와 data fitting에 의해 계산된 파라미터들이 실험치와 더 잘 일치함을 볼 수 있었다. 본 연구를 바탕으로, gradient 조건에서 유기산에 대한 이온 크로마토그래피의 거동 연구로 확장할 수 있다.

  • PDF

간호학생 대상 시뮬레이션기반 기본소생술 반복교육의 효과와 지속성 (Effectiveness and Retention of Repeated Simulation-based Basic Life Support Training for Nursing Students)

  • 정지수;허혜경
    • 중환자간호학회지
    • /
    • 제6권2호
    • /
    • pp.24-36
    • /
    • 2013
  • Propose: This study was to investigate the educational effect and retention of repeated simulation-based basic life support (BLS) training for nursing students. Methods: A comparison group design with pretest and posttest was used. A total of 35 nursing students (18 for the experimental group, 17 for the control group) participated in the study. A repeated simulationbased BLS training program which include a lecture, skills training, and two repeated sessions of simulation practice and debriefing was provided twice for experimental group. Knowledge, self-efficacy, and skill performance of cardiopulmonary resuscitation (CPR) were measured three times: at baseline, week 2, and week 6. Descriptive analysis, repeated measures ANOVA, and t-test were used for data analyses. Results: Knowledge, self-efficacy and skill performance of CPR were not significantly changed by group assignment, by the time, and interaction of group by time. Effectiveness of intervention was not maintained until Week 6. Conclusion: The results suggest that the timing of repeat education, total training time, and students' mastery of CPR performance should be considered when developing simulation-based programs to improve and maintain students' CPR knowledge, self-efficacy, and skill performance.

  • PDF

A survey on retention practice among orthodontists in Malaysia

  • Rahman, Norma Ab;Low, Tze Fui;Idris, Nur Shaheera
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.36-41
    • /
    • 2016
  • Objective: The aim of this study was to evaluate retention practices commonly employed by orthodontists. The objectives were to identify the types of retainer frequently used and to investigate the variations in retention practice. Methods: A total of 97 orthodontists were randomly selected, and a questionnaire consisting of 25 multiple-choice questions sent to them by mail. Upon receiving of the completed questionnaires, the data were statistically analyzed. Results: A total of 32 responses were received; among these, 59.4% of orthodontists' practiced is in a government setting and 40.6% were in private practice. A vacuum-formed retainer was the most commonly used removable retainer for both maxillary (46.9%) and mandibular (46.9%) arches, followed by a Hawley retainer (maxilla, 43.8%; mandible, 37.5%), and a fixed retainer (maxilla, 3.1%; mandible, 9.4%). Of the responding orthodontists, 78.1% prescribed full-time wear (more than 20 h per day) for a duration of 3-9 months for a maxillary arch, compared to 71.9% for the mandibular arch. Only 18.8% of the orthodontists prescribed part-time wear of the retainer for the maxillary arch, compared to 21.9% for the mandibular arch. The majority of orthodontists did not instruct their patients to stop wearing removable retainers (71.9%) or fixed retainers (66.8%) at any specific time and they preferred their patients to continue wearing retainers. Conclusions: Vacuum-formed retainers are the most commonly used retainers among orthodontists. The majority of orthodontists prescribed full-time wear for more than 20 h per day with a duration of 3-9 months and preferred indefinite use of the retainer.

DRAM의 Refresh 시간 개선을 위한 불순물 농도 최적화에 관한 연구 (The Study on Impurity Concentration Optimizing for the Refresh Time Improvement of DRAM)

  • Lee Yong-Hui;Woo Kyong-Hwan;Yi Cheon Hee
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.325-328
    • /
    • 2000
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. In this paper, we propose the new implantation scheme by gate-related ion beam shadowing effect and buffer-enhanced $\Delta$ Rp increase using buffered N- implantation with tilt and 4X-rotation that is designed on the basis of the local-field-enhancement model of the tail component. We report an excellent tail improvement of the retention time distribution attributed to the reduction of electric field across the cell junction due to the redistribution of N- concentration which is intentionally caused by Ion Beam Shadowing and Buffering Effect using tilt implantation with 4X-rotation.

  • PDF