• Title/Summary/Keyword: Data Retention Time

Search Result 231, Processing Time 0.024 seconds

A Study on Refresh Time Improvement of DRAM using the MEDICI Simulator (MEDICI 시뮬레이터를 이용한 DRAM의 Refresh 시간 개선에 관한 연구)

  • 이용희;이천희
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.4
    • /
    • pp.51-58
    • /
    • 2000
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. The novel junction process scheme in sub-micron DRAM cell with STI(Shallow Trench Isolation) has been investigated to improve the tail component in the retention time distribution which is of great importance in DRAM characteristics. In this' paper, we propose the new implantation scheme by gate-related ion beam shadowing effect and buffer-enhanced ${\Delta}Rp$ (projected standard deviation) increase using buffered N-implantation with tilt and 4X(4 times)-rotation that is designed on the basis of the local-field-enhancement model of the tail component. We report an excellent tail improvement of the retention time distribution attributed to the reduction of electric field across the cell junction due to the redistribution of N-concentration which is Intentionally caused by ion Beam Shadowing and Buffering Effect using tilt implantation with 4X-rotation. And also, we suggest the least requirements for adoption of this new implantation scheme and the method to optimize the key parameters such as tilt angle, rotation number, Rp compensation and Nd/Na ratio. We used MEDICI Simulator to confirm the junction device characteristics. And measured the refresh time using the ADVAN Probe tester.

  • PDF

Membrane fouling in thermophilic membrane bioreactor with different sludge retention times

  • Ince, Elif;Ince, Mahir;Topaloglu, Alikemal
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.343-351
    • /
    • 2018
  • As membrane fouling is based on various factors, it is a complex phenomenon that is hard to estimate. This study investigated membrane fouling in a thermophilic jet loop membrane bioreactor (JLMBR). With this purpose, four different empirical membrane fouling models with different sludge retention times were applied on the flow data obtained in the system. As a result of the model implementation, it was found for all sludge retention times that, standard blocking is effective in the first 1.5 hours of filtration, while cake filtration was dominant in the remaining duration. Additionally, it was observed that as the sludge retention time increases, membrane fouling rate decreases.

Analysis of Middle School Students' Retention Types about Results of Evaluation in School Mathematics (중학생들의 수학과 평가 결과의 파지 유형 분석)

  • Kim, Min-Ju;Kang, Yun-Soo
    • Communications of Mathematical Education
    • /
    • v.21 no.2 s.30
    • /
    • pp.331-345
    • /
    • 2007
  • This research is aimed to inquiry retention types of middle school students about results of evaluation in school mathematics, For this purpose, we selected evaluation time, problem types, evaluation score, evaluation factors as important factors which influence to students' retention types. Then we classified students' retention types about results of evaluation in school mathematics. From this results, we selected two students as participants, and collected data through depth interviews of them. In depth interviews, we focused on 'what is the core factor influenced to students' evaluation', 'how the core factors reappear in the future'. Through this process, we analyzed middle school students' retention types about results of evaluation in school mathematics.

  • PDF

Retention Characteristics of Various Proteins in Flow Field-Flow Fractionation : Effects of pH, Ionic Strength, and Denaturation

  • 송종희;김원숙;박영훈;유의경;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1159-1164
    • /
    • 1999
  • The study investigated the effect of carrier composition (ionic strength and pH) on the retention of various proteins in flow field-flow fractionation (Flow FFF) as well as the conformational change of Bovine Serum Albumin (BSA) with urea concentration, storage time and temperature. The study found that the retention of protein in Flow FFF increased with the ionic strength of the carrier liquid. Most proteins were well solubilized at pH = 7-8. The hydrodynamic diameters obtained from Flow FFF retention data agree well with theoretical values. The retention increased and the peak shape became distorted at extreme pH conditions of the carrier solution. The selected carrier composition for comparison between the literature value of proteins was 0.05 M tris buffer solution with a pH of 8. Storing BSA at 4 ±2℃ over a period of three months resulted in slow dimerization. Also, in case of the storage of BSA at 37 ±5℃ for one week, the retention of both BSA monomer and dimer increased with the urea concentration. Finally, the structural composition of specific enzymes: malonyl-CoA decarboxylase (MCDC) and malonyl-CoA synthesis (MCS) was determined by using Flow FFF at specific carrier solutions. The molecular weight of the natural MCDC was determined to be 208 kDa, which means it is a homotetramer, while that of the MCS was determined to be 47 kDa, which means it is a monomer.

A Study on the Identification of Target Compounds From the GC/MS Data (GC/MS분석자료의 목표물질 인식에 관한 연구)

  • 민홍기;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.223-228
    • /
    • 1989
  • In this paper, the computerized interpretation of the analytical chemical data, especially GC/MS data, was performed for the purpose of prescreening of the target compounds. First, the data from the analytical instrument was analyzed to get the information about the retention time of the ISTD and the time inteval between the records. Second, the identification of the characteristic ion peaks was performed by calculating the ratio of the heights and the relative slope sensitivity of the characteristic mass abundance.

  • PDF

Dynamic Customer Population Management Model at Aggregate Level

  • Kim, Geon-Ha
    • Management Science and Financial Engineering
    • /
    • v.16 no.3
    • /
    • pp.49-70
    • /
    • 2010
  • Customer population management models can be classified into three categories: the first category includes the models that analyze the customer population at cohort level; the second one deals with the customer population at aggregate level; the third one has interest in the interactions among the customer populations in the competitive market. Our study proposes a model that can analyze the dynamics of customer population in consumer-durables market at aggregate level. The dynamics of customer population includes the retention curves from the purchase or at a specific duration time, the duration time expectancy at a specific duration time, and customer population growth or decline including net replacement rate, intrinsic rate of increase, and the generation time of customer population. For this study, we adopt mathematical ecology models, redefine them, and restructure interdisciplinary models to analyze the dynamics of customer population at aggregate level. We use the data of previous research on dynamic customer population management at cohort level to compare its results with those of ours and to demonstrate the useful analytical effects which the precious research cannot provide for marketers.

Prediction of Organic Acid Chromatogram in High Performance Ion Chromatography (고성능 이온 크로마토그래피에서 유기산의 크로마토그램 예측 연구)

  • 원혜진;한선호;박양순;조기수;김인호
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.60-65
    • /
    • 2000
  • In order to predict the chromatogram for organic acid in ion chromatography, Langmuir isotherm parameters were obtained by Retention Time Method (RTM) and moment method. Ion chromatography analysis for formic acid was performed and compared with theoretically predicted profiles under isocratic condition. Band profiles were estimated with the equilibrium-dispersive model of chromatography using a PDEsolver Macsyma . The relationship between the characteristics of chromatogram and the variable operating condition in chromatography such as the flow rate, ionic strength and injection volume was studied. Satisfactory agreement was observed between the experimental and the estimated chromatograms with parameters obtained form the moment method.

  • PDF

Effectiveness and Retention of Repeated Simulation-based Basic Life Support Training for Nursing Students (간호학생 대상 시뮬레이션기반 기본소생술 반복교육의 효과와 지속성)

  • Jung, Ji Soo;Hur, Hea Kung
    • Journal of Korean Critical Care Nursing
    • /
    • v.6 no.2
    • /
    • pp.24-36
    • /
    • 2013
  • Propose: This study was to investigate the educational effect and retention of repeated simulation-based basic life support (BLS) training for nursing students. Methods: A comparison group design with pretest and posttest was used. A total of 35 nursing students (18 for the experimental group, 17 for the control group) participated in the study. A repeated simulationbased BLS training program which include a lecture, skills training, and two repeated sessions of simulation practice and debriefing was provided twice for experimental group. Knowledge, self-efficacy, and skill performance of cardiopulmonary resuscitation (CPR) were measured three times: at baseline, week 2, and week 6. Descriptive analysis, repeated measures ANOVA, and t-test were used for data analyses. Results: Knowledge, self-efficacy and skill performance of CPR were not significantly changed by group assignment, by the time, and interaction of group by time. Effectiveness of intervention was not maintained until Week 6. Conclusion: The results suggest that the timing of repeat education, total training time, and students' mastery of CPR performance should be considered when developing simulation-based programs to improve and maintain students' CPR knowledge, self-efficacy, and skill performance.

  • PDF

A survey on retention practice among orthodontists in Malaysia

  • Rahman, Norma Ab;Low, Tze Fui;Idris, Nur Shaheera
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.36-41
    • /
    • 2016
  • Objective: The aim of this study was to evaluate retention practices commonly employed by orthodontists. The objectives were to identify the types of retainer frequently used and to investigate the variations in retention practice. Methods: A total of 97 orthodontists were randomly selected, and a questionnaire consisting of 25 multiple-choice questions sent to them by mail. Upon receiving of the completed questionnaires, the data were statistically analyzed. Results: A total of 32 responses were received; among these, 59.4% of orthodontists' practiced is in a government setting and 40.6% were in private practice. A vacuum-formed retainer was the most commonly used removable retainer for both maxillary (46.9%) and mandibular (46.9%) arches, followed by a Hawley retainer (maxilla, 43.8%; mandible, 37.5%), and a fixed retainer (maxilla, 3.1%; mandible, 9.4%). Of the responding orthodontists, 78.1% prescribed full-time wear (more than 20 h per day) for a duration of 3-9 months for a maxillary arch, compared to 71.9% for the mandibular arch. Only 18.8% of the orthodontists prescribed part-time wear of the retainer for the maxillary arch, compared to 21.9% for the mandibular arch. The majority of orthodontists did not instruct their patients to stop wearing removable retainers (71.9%) or fixed retainers (66.8%) at any specific time and they preferred their patients to continue wearing retainers. Conclusions: Vacuum-formed retainers are the most commonly used retainers among orthodontists. The majority of orthodontists prescribed full-time wear for more than 20 h per day with a duration of 3-9 months and preferred indefinite use of the retainer.

The Study on Impurity Concentration Optimizing for the Refresh Time Improvement of DRAM (DRAM의 Refresh 시간 개선을 위한 불순물 농도 최적화에 관한 연구)

  • Lee Yong-Hui;Woo Kyong-Hwan;Yi Cheon Hee
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.325-328
    • /
    • 2000
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. In this paper, we propose the new implantation scheme by gate-related ion beam shadowing effect and buffer-enhanced $\Delta$ Rp increase using buffered N- implantation with tilt and 4X-rotation that is designed on the basis of the local-field-enhancement model of the tail component. We report an excellent tail improvement of the retention time distribution attributed to the reduction of electric field across the cell junction due to the redistribution of N- concentration which is intentionally caused by Ion Beam Shadowing and Buffering Effect using tilt implantation with 4X-rotation.

  • PDF