• 제목/요약/키워드: Data Piping

검색결과 265건 처리시간 0.026초

원자력발전소 배관 내부 매질이 초음파검사에 미치는 영향 평가 (Evaluation on the Effect of Ultrasonic Testing due to Internal Medium of Pipe in Nuclear Power Plant)

  • 윤병식;김용식;양승한
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.25-30
    • /
    • 2013
  • The periodic inspection of piping and pressure vessels welds in nuclear power plant has to provide reliable result related to weld flaws, such as location, maximum amplitude response, ultrasonic length, height and finally the nature or flaw pattern. The founded flaw in ultrasonic inspection is accepted or rejected based on these data. Specially, the amplitude of flaw response is used as basic parameter for flaw sizing and it may cause some deviation in length sizing result. Currently the ultrasonic inspections in nuclear power plant components are performed by specific inspection procedure which describing inspection technique include inspection system, calibration methodology and flaw characterizing. To perform ultrasonic inspection during in-service inspection, reference gain should be established before starting ultrasonic inspection by the requirement of ASME code. This reference gain used as basic criteria to evaluate flaw sizing. Sometimes, a little difference in establishing reference gain between calibration and field condition can lead to deviation in flaw sizing. Due to this difference, the inspection result may cause flaw sizing error. Therefore, the objective of this study is to compare and evaluate the ultrasonic amplitude difference between air filled and water filled pipe in nuclear power plant. Additionally, the accuracy of flaw sizing is estimated by comparing both conditions.

Pipe thinning model development for direct current potential drop data with machine learning approach

  • Ryu, Kyungha;Lee, Taehyun;Baek, Dong-cheon;Park, Jong-won
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.784-790
    • /
    • 2020
  • The accelerated corrosion by Flow Accelerated Corrosion (FAC) has caused unexpected rupture of piping, hindering the safety of nuclear power plants (NPPs) and sometimes causing personal injury. For the safety, it may be necessary to select some pipes in terms of condition monitoring and to measure the change in thickness of pipes in real time. Direct current potential drop (DCPD) method has advantages in on-line monitoring of pipe wall thinning. However, it has a disadvantage in that it is difficult to quantify thinning due to various thinning shapes and thus there is a limitation in application. The machine learning approach has advantages in that it can be easily applied because the machine can learn the signals of various thinning shapes and can identify the thinning using these. In this paper, finite element analysis (FEA) was performed by applying direct current to a carbon steel pipe and measuring the potential drop. The fundamental machine learning was carried out and the piping thinning model was developed. In this process, the features of DCPD to thinning were proposed.

단열배관의 온라인 두께측정시스템 개발 (Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline)

  • 장지훈;김병주;조경식;김기동
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF

원전 2차측 배관 감육여부 판별을 위한 Total Point Method 전산 알고리즘 개발 (Development of Numerical Algorithm of Total Point Method for Thinning Evaluation of Nuclear Secondary Pipes)

  • 오영진;윤훈;문승재;한경희;박병욱
    • 한국압력기기공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.31-39
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion (FAC) and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall-thinning that includes periodic measurements for pipe wall thicknesses using ultrasonic tests (UTs). Nevertheless, thinning evaluations are not easy because the amount of thickness reduction being measured is often quite small compared to the accuracy of the inspection technique. U.S. Electric Power Research Institute (EPRI) had proposed Total Point Method (TPM) as a thinning occurrence evaluation method, which is a very useful method for detecting locally thinned pipes or fittings. However, evaluation engineers have to discern manually the measurement data because there are no numerical algorithm for TPM. In this study, numerical algorithms were developed based on non-parametric and parametric statistical method.

Seismic Fragility of Steel Piping System Based on Pipe Size, Coupling Type, and Wall Thickness

  • Ju, Bu Seog;Gupta, Abhinav;Ryu, Yonghee
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1200-1209
    • /
    • 2018
  • In this study, a probabilistic framework of the damage assessment of pipelines subjected to extreme hazard scenario was developed to mitigate the risk and enhance design reliability. Nonlinear 3D finite element models of T-joint systems were developed based on experimental tests with respect to leakage detection of black iron piping systems, and a damage assessment analysis of the vulnerability of their components according to nominal pipe size, coupling type, and wall thickness under seismic wave propagations was performed. The analysis results showed the 2-inch schedule 40 threaded T-joint system to be more fragile than the others with respect to the nominal pipe sizes. As for the coupling types, the data indicated that the probability of failure of the threaded T-joint coupling was significantly higher than that of the grooved type. Finally, the seismic capacity of the schedule 40 wall thickness was weaker than that of schedule 10 in the 4-inch grooved coupling, due to the difference in the prohibition of energy dissipation. Therefore, this assessment can contribute to the damage detection and financial losses due to failure of the joint piping system in a liquid pipeline, prior to the decision-making.

하천제방 유지관리 기술의 고도화를 위한 하천제방 안전도맵 평가체계 제안 (Evaluation System of River Levee Safety Map for Improving River Levee Maintenance Technology)

  • 김진만;문인종
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.768-777
    • /
    • 2017
  • 세계 각국은 기후 및 홍수사상의 변화와 이에 따른 각종 수재해 시나리오에 대응하기 위하여 하천제방 유지관리기술을 고도화하고 있는 추세이다. 이러한 세계적 동향에 따라 본 연구에서는 하천제방을 효율적으로 유지관리할 수 있도록 하천제방 안전도맵 평가체계를 제안하고자 한다. 하천제방 안전도맵의 개념은 현행 하천제방의 활동, 파이핑, 육안점검 등의 안전도 지표를 GIS맵 상에 지도형태로 표출함으로써 하천관리자의 유지관리효율을 극대화하는 것이다. 이러한 평가체계를 구축하기 위해서 관련 문헌 및 자료 조사를 통해 활동, 파이핑, 육안점검 등 주요 안전도 지표를 선정하였으며, 각각의 안전도 지표를 A, B, C 등 3등급으로 평가할 수 있는 합리적인 기준을 제시하였다. 제시된 기준을 바탕으로 수치해석을 활용하여 시범구간(남강)에 대한 홍수위지속시간 변화에 따른 활동 및 파이핑 안전도 특성을 평가하였다. 시범평가 결과, 활동의 경우 제내외지 구분 없이 모두 A등급을 만족하였으며, 파이핑의 경우 R2에서 홍수위지속시간이 증가함에 따라 파이핑 등급 C등급으로 감소하는 경향을 확인하였다. 본 연구는 하천제방 안전도맵 평가체계를 제안하는 기획연구로서 하천제방 안전도맵 평가체계를 구축하기 위해서는 추후 개선된 추가 연구, 하천제방 자료의 표준화, 제도 및 관련 법 개선 등이 필요할 것으로 판단된다.

감마선을 이용한 단열배관의 실시간 두께측정시스템 개발 (Development of Real-Time Thickness Measuring System for Insulated Pipeline Using Gamma-ray)

  • 장지훈;김병주;김기동;조경식
    • 비파괴검사학회지
    • /
    • 제22권5호
    • /
    • pp.500-507
    • /
    • 2002
  • 본 연구에서는 감마선과 섬광체 및 광 다이오드로 구성된 64 채널의 선형 디텍터 어레이를 이용하여 보온재로 싸인 배관의 두께를 실시간으로 측정하는 시스템을 개발하였다. 본 측정시스템은 감마선원으로 Ir-192를 사용하였으며, 디텍터는 BGO 섬광체와 광다이오드로 구성하였다. Ir-192 방사선원은 배관의 한쪽 편에, 그리고 디텍터 어레이는 배관을 중심으로 그 반대편에 위치하며 컴퓨터로 제어되는 주행 시스템에 실려 배관을 따라 이송되는 동안 배관과 단열재를 투과한 방사선의 강도는 각 디텍터에서 측정된다. 측정된 디텍터 어레이의 출력은 증폭기에서 증폭된 후 케이블에 의해 컴퓨터로 전송되며 주행시스템이 진행하는 동안 컴퓨터는 수집된 신호를 분석 및 계산하여 실제의 두께를 나타내며 주사간격을 1mm로 할 경우의 최대 측정속도는 분당 120cm이다.

수치해석을 이용한 하천제방의 건전도 평가 (River Embankment Integrity Evaluation using Numerical Analysis)

  • 변요셉;정혁상;김진만;최봉혁;김경민;천병식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.524-528
    • /
    • 2009
  • An influence factors for soundness evaluation of river levee include resistibility and embankment for piping of ground consisting embankment in case piping, permeability coefficient of ground, height of embankment, the width of crest, material characteristics of embankment and foundation ground, shape of embankment slope, an influence for penetration of rainfall or river water in case slope stability. In this study, it was operated a feasibility investigation of existing design result, stability evaluation for permeability coefficient use and permeability coefficient change of foundation ground to investigate an influence in line with permeability coefficient change for result of river levee penetration analysis. The evaluation results of influence factors, the permeability coefficient used in design and it was evaluated influence in safety factor of piping. After the evaluation of influence factors, the permeability coefficient used in the design appears with the fact that differs in a design report about same soil, Accordingly, the stability investigation of embankment by application of literature data can affect stability evaluation results by change factors like a permeability coefficient, void ratio. It should be certainly used material properties by a test in soundness evaluation of river levee.

  • PDF

가속도계를 이용한 탄성파 기반 누수탐지 기술 분석 (Analysis of Elastic Wave Based Leakage Detection Technology Using Accelerometers)

  • 최광묵;이호현;신강욱;홍성택
    • 한국정보통신학회논문지
    • /
    • 제24권9호
    • /
    • pp.1231-1240
    • /
    • 2020
  • 상수도 배관은 땅속에 매설되어 있어서 배관의 노후화에 따른 누수를 맨눈으로 탐지하기가 불가능하며, 누수음을 감지함으로써 배관의 누수를 탐지하는 기술이 주로 사용된다. 본 논문에서는 상수도 배관의 양단에 두 개의 가속도계를 부착·취득한 데이터 간의 도달 시간 차이를 계산하여 누수 지점을 탐지하는 알고리즘을 개발하였다. 배관의 누수 시험은 17.2m의 배관에 4.3m, 8.6m, 12.9m 지점에 밸브를 설치하고, 밸브의 개도율을 30%, 70%로 변경해 가면서 누수 지점을 분석하였으며, 밸브가 30%, 70%씩 개방된 정도의 배관 내 압력 강하에 대해서는 누수를 탐지할 수 있는 것으로 확인되었다. 초기 단계의 누수를 탐지하는 것이 매우 중요하며, 본 연구에서 적용한 알고리즘으로부터 초기의 누수 지점의 탐지가 가능할 것으로 판단된다.

플랜트 건설의 현장시공 및 모듈시공에 대한 공사비 비교 사례연구 - Pipe Rack을 대상으로 공사비 산정 - (A Case Study on Construction Cost Comparison for On-Site Construction and Off-Site Construction of Plant Project)

  • 강현욱
    • 한국건설관리학회논문집
    • /
    • 제24권4호
    • /
    • pp.25-34
    • /
    • 2023
  • 본 연구의 목적은 플랜트 건설에서 현장시공과 모듈시공에 대한 공사비를 산정하여 비교하는 것으로 공사비를 산정하는 대상을 Pipe Rack으로 한정하였다. 이에, 현장시공으로 준공된 국내 석유화학플랜트 건설사업 1곳을 사례로 선정한 후 비용자료를 조사하여 도출된 결과는 다음과 같다. Pipe Rack의 현장시공에 대한 직접공사비는 560억원으로 Steel Structure 251억원, Piping 308억원이며, 모듈시공에 대한 직접공사비는 607억원으로 Steel Structure 238억원, Piping 297억원으로 산정되었다. 또한, 현장시공과 모듈시공의 증감률을 비교해 보면, 재료비 1.9%, 경비 192.1% 증액되었으나, 노무비는 -9.1% 감액되어, 전체 직접공사비는 8.4%(47억원)가 증액되었다. 그리고 공사원가는 현장시공이 761억원, 모듈시공은 810억원으로 모듈시공이 6.4%(49억원) 증액되는 것으로 나타났다. 이와 같은 결과는 Pipe Rack을 모듈로 시공하는 경우 공사비가 증감되는 현황을 확인하기 위한 참고자료로 활용이 용이한 반면에, 모듈시공에 따른 간접적인 효과(노무인력 감소, 안전사고 발생 감소, 공사기간 단축 등)에 대한 연구가 필요하다.