• 제목/요약/키워드: Data Decompression

검색결과 101건 처리시간 0.026초

Volume change pattern of decompression of mandibular odontogenic keratocyst

  • Park, Jin Hoo;Kwak, Eun-Jung;You, Ki Sung;Jung, Young-Soo;Jung, Hwi-Dong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.2.1-2.6
    • /
    • 2019
  • Objectives: This study was aimed to analyze the reducing pattern of decompression on mandibular odontogenic keratocyst and to determine the proper time for secondary enucleation. Materials and methods: Seventeen patients with OKC of the mandible were treated by decompression. Forty-five series of CT data were taken during decompression and measured by using InVivo software (Anatomage, San Jose, Calif) and were analyzed. Results: The expected relative volume during decompression is calculated using the following formula: V(t) = Vinitial × exp.(at + 1/2bt2) (t = duration after decompression (day)). There was no significant directional indicator in the rate of reduction between buccolingual and mesiodistal widths. Conclusion: The volume reduction rate gradually decreased, and 270 days were required for 50% volume reduction following decompression of OKC. The surgeon should be aware of this pattern to determine the timing for definitive enucleation. Clinical relevance: The volume reduction rate and pattern of decompression of the OKC can be predicted and clinicians should be considered when treating OKC via decompression.

Performance of Decompression Orifices Attached to Indoor Hydrant Discharge Outlets (옥내소화전 방수구에 부착되는 감압오리피스의 감압성능에 관한 연구)

  • Park, Bong-Rae;Lee, Meng-Ro;Jang, Kyung-Nam;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • 제29권3호
    • /
    • pp.6-12
    • /
    • 2015
  • Indoor hydrant facilities are used to fight initial fires before more intense fire extinguishing activities. Fire extinguishing facilities should ensure good fire extinguishing performance and the safety of users. Indoor hydrant facilities are mostly installed in buildings and facilities, and users must manipulate valves, hoses, and nozzles manually. When the discharge pressure is higher than 0.70 MPa, there is a high possibility that problems with manipulation and hose breakdown can occur. To prevent these problems, a method to attach orifice-type decompression valves to the angle valves of indoor hydrant discharge outlets has frequently been used for decompression methods. However, the decompression performance was reduced due to structural problems of the decompression valves over time. Accordingly, based on three-stage initial pressures, applicable pressure ranges were selected by measuring the decompression performance according to the diameter of the decompression orifices. Based on the data, stable decompression valve models are proposed. These models have the lowest decrease in decompression performance, regardless of time.

An Efficient Test Data Compression/Decompression Using Input Reduction (IR 기법을 이용한 효율적인 테스트 데이터 압축 방법)

  • 전성훈;임정빈;김근배;안진호;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제41권11호
    • /
    • pp.87-95
    • /
    • 2004
  • This paper proposes a new test data compression/decompression method for SoC(Systems-on-a-Chip). The method is based on analyzing the factors that influence test parameters: compression ratio and hardware overhead. To improve compression ratio, the proposed method is based on Modified Statistical Coding (MSC) and Input Reduction (IR) scheme, as well as a novel mapping and reordering algorithm proposed in a preprocessing step. Unlike previous approaches using the CSR architecture, the proposed method is to compress original test data and decompress the compressed test data without the CSR architecture. Therefore, the proposed method leads to better compression ratio with lower hardware overhead than previous works. An experimental comparison on ISCAS '89 benchmark circuits validates the proposed method.

Proposal for Decoding-Compatible Parallel Deflate Algorithm by Inserting Control Header Composed of Non-Compressed Blocks (비 압축 블록으로 구성된 제어 헤더 삽입을 통한 압축 해제 호환성 있는 병렬 처리 Deflate 알고리즘 제안)

  • Kim Jung Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • 제12권5호
    • /
    • pp.207-216
    • /
    • 2023
  • For decoding-compatible parallel Deflate algorithm, this study proposed a new method of the control header being made in such a way that essential information for parallel compression and decompression are stored in the Disposed Bit Area (DBA) of the non-compression block and being inserted into the compressed blocks. Through this, parallel compression and decompression are possible while maintaining perfect compatibility with the existing decoder. After applying this method, the compression time was reduced by up to 71.2% compared to the sequential processing method, and the parallel decompression time was reduced by up to 65.7%. In particular, it is well known that parallel decompression is impossible due to the structural limitations of the Deflate algorithm. However, the decoder equipped with the proposed method enables high-speed parallel decompression at the algorithm level and maintains compatibility, so that parallelly compressed data can be decoded normally by existing decoder programs.

The Short Term Effects of the Decompression (KNX $7000^{(R)}$) and Traction Device on Pain in Patients with Chronic Low Back Pain with or without Radicular Pain (만성 요통 및 하지방사통 환자에서 감압치료(KNX $7000^{(R)}$)와 견인치료의 단기 치료 효과)

  • Park, So-Hyun;Kim, Chul-Seoung;Lee, Dong-Gyu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • 제23권5호
    • /
    • pp.29-34
    • /
    • 2011
  • Purpose: The purpose of this study is to evaluate the short term effects of the traction and decompression device, which is a newly developed domestic medical device, on pain and functional activity in patients with chronic low back pain with or without radicular pain. Methods: Forty patients with chronic low back pain were included and allocated to decompression (n=20) and traction groups (n=20). They received decompression or traction therapy for 20 minutes a day, 3 days per week for two weeks. For evaluating pain and functional activity, a visual analogue scale (VAS) for low back pain and the Oswestry back pain disability index (ODI) were obtained on pre-treatment, and at 6, 12 and 15 days after treatment. Patients'satisfaction levels were measured 15 days after treatment. Results: VAS was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in both groups (p<0.05). ODI was significantly decreased at 12 days and 15 days post-treatment compared to pre-treatment in the decompression group (p<0.05). However, there was no significant difference between the two groups in the VAS and ODI scales (p>0.05). Patients' satisfaction levels were significantly higher in the decompression group than in the traction group (p<0.05). Conclusion: These findings suggest that decompression therapy might be effective for increasing functional activity in patients with low back pain and could provide patients with higher satisfaction than traction therapy. This study provided validity data for the therapeutic effects of the decompression device in patients with low back pain and it will be useful for medical cost development and patient education of this device.

Sparse Matrix Compression Technique and Hardware Design for Lightweight Deep Learning Accelerators (경량 딥러닝 가속기를 위한 희소 행렬 압축 기법 및 하드웨어 설계)

  • Kim, Sunhee;Shin, Dongyeob;Lim, Yong-Seok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • 제17권4호
    • /
    • pp.53-62
    • /
    • 2021
  • Deep learning models such as convolutional neural networks and recurrent neual networks process a huge amounts of data, so they require a lot of storage and consume a lot of time and power due to memory access. Recently, research is being conducted to reduce memory usage and access by compressing data using the feature that many of deep learning data are highly sparse and localized. In this paper, we propose a compression-decompression method of storing only the non-zero data and the location information of the non-zero data excluding zero data. In order to make the location information of non-zero data, the matrix data is divided into sections uniformly. And whether there is non-zero data in the corresponding section is indicated. In this case, section division is not executed only once, but repeatedly executed, and location information is stored in each step. Therefore, it can be properly compressed according to the ratio and distribution of zero data. In addition, we propose a hardware structure that enables compression and decompression without complex operations. It was designed and verified with Verilog, and it was confirmed that it can be used in hardware deep learning accelerators.

Central Decompressive Laminoplasty for Treatment of Lumbar Spinal Stenosis : Technique and Early Surgical Results

  • Kwon, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권3호
    • /
    • pp.206-210
    • /
    • 2014
  • Objective : Lumbar spinal stenosis is a common degenerative spine disease that requires surgical intervention. Currently, there is interest in minimally invasive surgery and various technical modifications of decompressive lumbar laminectomy without fusion. The purpose of this study was to present the author's surgical technique and results for decompression of spinal stenosis. Methods : The author performed surgery in 57 patients with lumbar spinal stenosis between 2006 and 2010. Data were gathered retrospectively via outpatient interviews and telephone questionnaires. The operation used in this study was named central decompressive laminoplasty (CDL), which allows thorough decompression of the lumbar spinal canal and proximal two foraminal nerve roots by undercutting the lamina and facet joint. Kyphotic prone positioning on elevated curvature of the frame or occasional use of an interlaminar spreader enables sufficient interlaminar working space. Pain was measured with a visual analogue scale (VAS). Surgical outcome was analyzed with the Oswestry Disability Index (ODI). Data were analyzed preoperatively and six months postoperatively. Results : The interlaminar window provided by this technique allowed for unhindered access to the central canal, lateral recess, and upper/lower foraminal zone, with near-total sparing of the facet joint. The VAS scores and ODI were significantly improved at six-month follow-up compared to preoperative levels (p<0.001, respectively). Excellent pain relief (>75% of initial VAS score) of back/buttock and leg was observed in 75.0% and 76.2% of patients, respectively. Conclusion : CDL is easily applied, allows good field visualization and decompression, maintains stability by sparing ligament and bony structures, and shows excellent early surgical results.

Effect of whole body cryotherapy with spinal decompression on lumbar disc herniation by functional assessment measures (기능적 평가 측정을 통하여 전신냉기치료와 척추 감압기 적용이 요추 추간판 탈출증 환자에게 미치는 효과)

  • Ma, Sang-Yeol
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권6호
    • /
    • pp.1101-1108
    • /
    • 2010
  • This study was conducted to investigate whether whole body cryotherapy and spinal decompression have effectiveness on the pain, lumbar flexion range of motion, and global perceived effect scale in patients with lumbar disc herniation. Thirty subjects were participated in this study. And they were all randomly divided into whole body cryotherapy and spinal decompression group. To evaluate the effects of whole body cryotherapy and spinal decompression, subjects were evaluated by using visual analogue scale, lumbar flexion range of motion, and global perceived effect scale. The assessment parameters were evaluated before, after 2 weeks treatments. And we received a consent form whole body cryotherapy subjects. The results of paired t-test, independent t-test, and ANCOVA analysis of variance showed that pain, lumbar flexion range of motion, global perceived effect scale were significantly improved after than before therapy in whole body cryotherapy group. So we conclude that whole body cryotherapy has effectiveness on the pain, lumbar flexion range of motion, and global perceived effect scale in patients with lumbar disc herniation.

A Study on Compression and Decompression of Bit Map Data by NibbleRLE Code (니블 RLE 코드에 의한 비트 맵 데이타의 압축과 복원에 관한 연구)

  • Jo, Gyeong-Yeon
    • The Transactions of the Korea Information Processing Society
    • /
    • 제2권6호
    • /
    • pp.857-865
    • /
    • 1995
  • In this paper, a nibble RLE(Run Length Encoding) code for real time compression and decompression of Hanguel bit map font and printer data is proposed. The nibble RLE code shows good compression ratio in complete form Hangeul Myoungjo and Godik style bit map font and printer output bit map data. And two ASICs seperating compression and decompression are designed and simulated on CAD to verify the proposed code. The 0.8 micron CMOS Sea of Gate is used to implement the ASICs in amount of 2, 400 gates, and these are running at 25MHz. Therefore, the proposed code could be implemented with simple hardware and performs 100M bit/sec compression and decomression at maximum, it is good for real time applications.

  • PDF

Compression and Visualization Techniques for Time-Varying Volume Data (시변 볼륨 데이터의 압축과 가시화 기법)

  • Sohn, Bong-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • 제12권3호
    • /
    • pp.85-93
    • /
    • 2007
  • This paper describes a compression scheme for volumetric video data(3D space X 1D time) there each frame of the volume is decompressed and rendered in real-time. Since even one frame size of volume is very large, runtime decompression can be a bottleneck for real-time playback of time-varying volume data. To increase the run-time decompression speed and compression ratio, we decompose the volume into small blocks and only update significantly changing blocks. The results show that our compression scheme compromises decompression speed and image quality well enough for interactive time-varying visualization.

  • PDF