• Title/Summary/Keyword: Data Archiving

Search Result 186, Processing Time 0.031 seconds

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

A New Method of Registering the XML-based Clinical Document Architecture Supporting Pseudonymization in Clinical Document Registry Framework (익명화 방법을 적용한 임상진료문서 등록 기법 연구)

  • Kim, Il-Kwang;Lee, Jae-Young;Kim, Il-Kon;Kwak, Yun-Sik
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.10
    • /
    • pp.918-928
    • /
    • 2007
  • The goal of this paper is to propose a new way to register CDA documents in CDR (Clinical Document Repository) that is proposed by the author earlier. One of the methods is to use a manifest archiving for seamless references and visualization of CDA related files. Another method is to enhance the CDA security level for supporting pseudonymization of CDA. The former is a useful method to support the bundled registration of CDA related files as a set. And it also can provide a seamless presentation view to end-users, once downloaded, without each HTTP connection. The latter is a new method of CDA registration which can supports a do-identification of a patient. Usually, CDA header can be used for containing patient identification information, and CDA body can be used for diagnosis or treatment data. So, if we detach each other, we can get good advantages for privacy protection. Because even if someone succeeded to get separated CDA body, he/she never knows whose clinical data that is. The other way, even if someone succeeded to get separated CDA header; he/she doesn't know what kind of treatment has been done. This is the way to achieve protecting privacy by disconnecting association of relative information and reducing possibility of leaking private information. In order to achieve this goal, the method we propose is to separate CDA into two parts and to store them in different repositories.

Development of a Road Hazard Map Considering Meteorological Factors (기상인자를 고려한 도로 위험지도 개발)

  • Kim, Hyung Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.3
    • /
    • pp.133-144
    • /
    • 2017
  • Recently, weather information is getting closer to our real life, and it is a very important factor especially in the transportation field. Although the damage caused by the abnormal climate changes around the world has been gradually increased and the correlation between the road risk and the possibility of traffic accidents is very high, the domestic research has been performed at the level of basic research. The Purpose of this study is to develop a risk map for the road hazard forecasting service of weather situation by linking real - time weather information and traffic information based on accident analysis data by weather factors. So, we have developed a collection and analysis about related data, processing, applying prediction models in various weather conditions and a method to provide the road hazard map for national highways and provincial roads on a web map. As a result, the road hazard map proposed in this study can be expected to be useful for road managers and users through online and mobile services in the future. In addition, information that can support safe autonomous driving by continuously archiving and providing a risk map database so as to anticipate and preemptively prepare for the risk due to meteorological factors in the autonomous driving vehicle, which is a key factor of the 4th Industrial Revolution, and this map can be expected to be fully utilized.

Comparative study on the Shape between a Customized Finger Made by 3D Printing Technology, Real Small Finger, a plaster Small Finger, Based on CT Data (CT data 기반 3D 프린팅으로 제작된 Small Finger, 실제 Small Finger 그리고 석고 Small Finger 형상 비교 연구)

  • Choi, Hyeun-Woo;An, Do-Hyun;Rhee, Do-byung;Lee, Jong-Min;Seo, Anna
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.153-158
    • /
    • 2019
  • The purpose of this study is to compare and analyse the differences between a customized small finger made by 3D printing technology, a real small finger, and the other made from plaster of an orthotic company. The areas and the volumes of each cross-section were measured by Computer tomography(CT) and a 3D scanner and analysis of variance was performed to find out the differences of each shape. The areas of the point of 15.69mm, Distal Interphalangel Joints, were measured 30 times respectively using the caliper toll function of Picture Archiving Communication System(PASC) program. The volumes were measured by Configure Units of Meshmixer Program. There was no significant difference in the areas between three of them and there was 0.2 mm gap in the volume, which was more than the significance probability. Therefore, the result of this study shows the availability of finger orthoses made by 3D printing technology in the medical field.

Development of JPEG2000 Viewer for Mobile Image System (이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2003
  • Currently, as a consequence of PACS (Picture Archiving Communication System) implementation many hospitals are replacing conventional film-type interpretations of diagnostic medical images with new digital-format interpretations that can also be saved, and retrieve However, the big limitation in PACS is considered to be the lack of mobility. The purpose of this study is to determine the optimal communication packet size. This was done by considering the terms occurred in the wireless communication. After encoding medical image using JPGE2000 image compression method, This method embodied auto-error correction technique preventing the loss of packets occurred during wireless communication. A PC class server, with capabilities to load, collect data, save images, and connect with other network, was installed. Image data were compressed using JPEG2000 algorithm which supports the capability of high energy density and compression ratio, to communicate through a wireless network. Image data were also transmitted in block units coeded by JPEG2000 to prevent the loss of the packets in a wireless network. When JPGE2000 image data were decoded in a PUA (Personal Digital Assistant), it was instantaneous for a MR (Magnetic Resonance) head image of 256${\times}$256 pixels, while it took approximately 5 seconds to decode a CR (Computed Radiography) chest image of 800${\times}$790 pixels. In the transmission of the image data using a CDMA 1X module (Code-Division Multiple Access 1st Generation), 256 byte/sec was considered a stable transmission rate, but packets were lost in the intervals at the transmission rate of 1Kbyte/sec. However, even with a transmission rate above 1 Kbyte/sec, packets were not lost in wireless LAN. Current PACS are not compatible with wireless networks. because it does not have an interface between wired and wireless. Thus, the mobile JPEG2000 image viewing system was developed in order to complement mobility-a limitation in PACS. Moreover, the weak-connections of the wireless network was enhanced by re-transmitting image data within a limitations The results of this study are expected to play an interface role between the current wired-networks PACS and the mobile devices.

  • PDF

Estimation of the Surface Currents using Mean Dynamic Topography and Satellite Altimeter Data in the East Sea (평균역학고도장과 인공위성고도계 자료를 이용한 동해 표층해류 추산)

  • Lee, Sang-Hyun;Byun, Do-Seong;Choi, Byoung-Ju;Lee, Eun-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.14 no.4
    • /
    • pp.195-204
    • /
    • 2009
  • In order to estimate sea surface current fields in the East Sea, we examined characteristics of mean dynamic topography (MDT) fields (or mean surface current field, MSC) generated from three different methods. This preliminary investigation evaluates the accuracy of surface currents estimated from satellite-derived sea level anomaly (SLA) data and three MDT fields in the East Sea. AVISO (Archiving, Validation and Interpretation of Satellite Oceanographic data) provides a MDT field derived from satellite observation and numerical models with $0.25^{\circ}$ horizontal resolution. Steric height field relative to 500 dbar from temperature and salinity profiles in the East Sea supplies another MDT field. Trajectory data of surface drifters (ARGOS) in the East Sea for 14 years provide another MSC field. Absolute dynamic topography (ADT) field is calculated by adding SLA to each MDT. Application of geostrophic equation to three different ADT fields yields three surface geostrophic current fields. Comparisons were made between the estimated surface currents from the three different methods and in-situ current measurements from a ship-mounted ADCP (Acoustic Doppler Current Profiler) in the southwestern East Sea in 2005. For offshore areas more than 50 km away from the land, the correlation coefficients (R) between the estimated versus the measured currents range from 0.58 to 0.73, with 17.1 to $21.7\;cm\;s^{-1}$ root mean square deviation (RMSD). For coastal ocean within 50 km from the land, however, R ranges from 0.06 to 0.46 and RMSD ranges from 15.5 to $28.0\;cm\;s^{-1}$. Results from this study reveal that a new approach in producing MDT and SLA is required to improve the accuracy of surface current estimations for the shallow costal zones of the East Sea.

Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T (복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2016
  • This study conducted an analysis to compare the differences in the properties of the magnetic field and the generation of artifacts because of the difference in the magnetic field between 1.5 T equipment and 3.0 T equipment, centering around four types of pulse sequences, mainly applied to the abdominal Magnetic Resonance Imaging (MRI). With data on 500 persons transmitted to the PACS, this study analyzed the SNR value, quantitatively and carried out a qualitative evaluation, dividing MSA, CSA, and DA into three steps. As a result of the quantitative evaluation, the SNR value was significantly higher in the 1.5 T equipment; however, there was a factor deteriorating the image quality, too, as artifacts were generated in the images. The 1.5 T equipment generated fewer artifacts than the 3.0 T equipment did, so it could compensate the image quality for 3.0 T. In conclusion, based on these findings, this study could understand the differences in the properties of the magnetic field and the generation of artifacts occurring because of the difference in the magnetic field and could provide a measure for them. This study would be guidelines for MRI users who directly examine the patients in abdominal MRI using the two types of equipment in the clinical setting in the future.

A Study on Record Selection Strategy and Procedure in Dataset for Administrative Information (행정정보 데이터세트 기록의 선별 기준 및 절차 연구)

  • Cho, Eun-Hee;Yim, Jin-Hee
    • The Korean Journal of Archival Studies
    • /
    • no.19
    • /
    • pp.251-291
    • /
    • 2009
  • Due to the trend toward computerization of business services in public sector and the push for e-government, the volume of records that are produced in electronic system and the types of records vary as well. Of those types, dataset is attracting everyone's attention because it is rapidly being supplied. Even though the administrative information system stipulated as an electronic record production system is increasing in number, as it is in blind spot for records management, the system can be superannuated or the records can be lost in case new system is developed. In addition, the system was designed not considering records management, it is managed in an unsatisfactory state because of not meeting the features and quality requirements as records management system. In the advanced countries, they recognized the importance of dataset and then managed the archives for dataset and carried out the project on management systems and a preservation formats for keeping data. Korea also is carrying out the researches on an dataset and individual administrative information systems, but the official scheme has not been established yet. In this study the items for managing archives which should be reflected when the administrative information system is designed was offered in two respects - an identification method and a quality requirement. The major directions for this system are as follows. First, as the dataset is a kind of an electronic record, it is necessary to reflect this factor from the design step prior to production. Second, the system should be established integrating the strategy for records management to the information strategy for the whole organization. In this study, based on such two directions the strategies to establish the identification for dataset in a frame to push e-government were suggested. The problem on the archiving steps including preservation format and the management procedures in dataset archive does not included in the research contents. In line with this, more researches on those contents as well as a variety of researches on dataset are expected to be more actively conducted.

The Case Study on a Documentation of Mega Sports Event (메가 스포츠이벤트의 기록화를 위한 사례연구)

  • Cheon, Ho Jun
    • The Korean Journal of Archival Studies
    • /
    • no.42
    • /
    • pp.37-71
    • /
    • 2014
  • The purpose of this study was to analyze developed case of archiving on Mega Sport Event for searching effective method on a documentation of Mega Sport Event. In order to conduct this study, literature review method was using about book, thesis and data of internet homepage for exploring the stage on Mega Sports Event and case of Mega Sports Event record management. The field study was conducted about institute related to Olympic record management institution for analysing Mega Sports Event record management. The result of this study is following: Firstly, 2012London Organizing Committee of the Olympic Games's case(The People's Record Project) is useful to ex-ante event phase. Secondly, 2000Sydney Organizing Committee of the Olympic Games's case(Olympic Games Knowledge Management Project) is useful to event operation phase. Thirdly. LA84Foundation's case(Olympic Oral History Project) is useful to ex-post event. The significance of this study which came up with the study result above can be presented as follows. Based on the result of this study, it is assumed that three case for documentation about Mega Sports Event. Lastly, the result of this study was useful to Mega Sports Event record management institution. For the more, it will be conducted to study law of Mega Sport Event record management, humane and Material resource and method related to record management of the Mega Sports Event organizing committee.

Assessing the relationship between muscle-to-fat ratio in pork belly and Boston butt using magnetic resonance imaging

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Juyoun Kang;Haram Kim;Yeongjae Chae;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;Yunseok Kim;Pil Nam Seong;In-Seon Bae;Soohyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.51 no.2
    • /
    • pp.187-192
    • /
    • 2024
  • This research aimed to investigate the relationship between meat quality and muscle-to-fat ratio in specific cuts of pork (pork belly and Boston butt) utilizing magnetic resonance imaging (MRI). Twenty-eight pigs were selected, and 24 hours post-slaughter, pork belly and Boston butt samples were individually extracted from the left half carcass for MRI assessment. The MRI scans were reviewed using the Picture Archiving and Communications System. Muscle and fat volumes in the pork belly and Boston butt from the cross-sectional images captured by MRI were estimated using Vitrea workstation version 7. Subsequently, these data were processed using Vitrea post-processing software to automatically determine the volumes, measured in milliliters (mL). Additionally, a three-dimensional reconstruction of the organ being studied was generated. The relationship between regions (pork belly and Boston butt) was assessed using Pearson's correlation coefficient, and statistical analysis was conducted using Graph Pad Prism 8. The muscle-to-fat ratio determined by MRI for pork belly was 1 : 0.64, whereas for Boston butt it was 1 : 0.35. Results of comparing the muscle-fat ratio, the correlation coefficient between pork belly and Boston butt was found to be 0.6127 (R2 = 0.3754, p < 0.001) based on MRI analysis. As a result of measuring the muscle-to-fat ratio using MRI as a non-destructive approach, there was a positive correlation between the muscle-to-fat ratios of pork belly and Boston butt.