Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T  

Goo, Eun-Hoe (Department of Radiological Science, Cheongju University)
Publication Information
Journal of the Korean Society of Radiology / v.10, no.5, 2016 , pp. 367-373 More about this Journal
Abstract
This study conducted an analysis to compare the differences in the properties of the magnetic field and the generation of artifacts because of the difference in the magnetic field between 1.5 T equipment and 3.0 T equipment, centering around four types of pulse sequences, mainly applied to the abdominal Magnetic Resonance Imaging (MRI). With data on 500 persons transmitted to the PACS, this study analyzed the SNR value, quantitatively and carried out a qualitative evaluation, dividing MSA, CSA, and DA into three steps. As a result of the quantitative evaluation, the SNR value was significantly higher in the 1.5 T equipment; however, there was a factor deteriorating the image quality, too, as artifacts were generated in the images. The 1.5 T equipment generated fewer artifacts than the 3.0 T equipment did, so it could compensate the image quality for 3.0 T. In conclusion, based on these findings, this study could understand the differences in the properties of the magnetic field and the generation of artifacts occurring because of the difference in the magnetic field and could provide a measure for them. This study would be guidelines for MRI users who directly examine the patients in abdominal MRI using the two types of equipment in the clinical setting in the future.
Keywords
Signal to noise ratio; Magnetic susceptibility artifact; Chemical shift artifact; Dielectric artifact; Picture archiving communication system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 C. Zhu, H. Haraldsson, F. Faraji, C. Owens, W. Gasper, S. Ahn, J. Liu, G. Laub, M. D. Hope, D. Saloner, “Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus,” Magn Reson Imaging, Vol. 34, No. 1, pp. 18-25, 2016.   DOI
2 J. D. Collins, “Unsuspected Herniated Lung Obstructing the Right Internal Jugular Vein and Internal Carotid Artery in a Patient with Thoracic Outlet Syndrome: MRI/MRA and MRV,” J Natl Med Association, Vol. 108, No. 2, pp. 106-112, 2016.   DOI
3 J. Guo, N. Chen, R. Li, Q. Wu, H. Chen, Q. Gong, L. He, “Regional homogeneity abnormalities in patients with transient ischaemic attack: a resting-state fMRI study,” Clin Neurophysiol, Vol. 125, No. 3, pp. 520-525, 2014.   DOI
4 J. A. Goncalves Neto, E. Altun, M. Elazzazi, G. D. Vaidean, M. Chaney, R. C. Semelka, “Enhancement of abdominal organs on hepatic arterial phase: quantitative comparison between 1.5-and 3.0-T magnetic resonance imaging,” Magn Reson Imaging, Vol. 28, No. 1, pp. 47-55, 2010.   DOI
5 H. Kataoka, T. Kiriyama, T. Taoka, N. Oba, M. Takewa, N Eura, R. Syobatake, Y. Kobayashi, M. Kumazawa, T. Izumi, Y. Furiya, N. Aoyama, N. Kichikawa, "Comparison of brain3.0-T with 1.5-TMRI in patients with multiple sclerosis: a 6-month follow-up study," Clin Neurol Neurosurg, Vol. 121, doi: 10.1016/j.clineuro.2014.03.018, pp. 55-58, 2014.   DOI
6 G. B Joseph, C. E. McCulloch, M. C. Nevitt, U. Heilmeier, L. Nardo, J. A Lynch, F. Liu, T. Baum, T. M. Link, “A reference database of cartilage 3T MRI T2 values in knees without diagnostic evidence of cartilage degeneration: data from the osteoarthritis initiative,” Osteoarthritis Cartilage, Vol. 23, No. 6., pp. 897-905, 2015.   DOI
7 M. Ramalho, I. Hithaya, M. AlObaidy, J. Kalubowil a, Y. H. Jeon, S. Manikkavasakar, R. C. Semelka, “MRI Evaluation of cooperative and non-cooperative patients with non-traumatic acute abdominal pain-pre liminary observations,” Clin Imaging, Vol. 40, No. 4, pp. 707-713, 2016.   DOI
8 J. Y. Choi, M. J. Kim, Y. E. Chung, J. Y. Kim, A. C. Jones, J. de Becker, M. van Cauteren, “ Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-Tsystem,” Radiographics, Vol. 28, No. 4, pp. 1-29, 2008.   DOI
9 M. M Barth, M. P. Smith, I. Pedrosa, R. E. Lenkinski, N. M. Rofsky, “Body MR imaging at 3.0T: understanding the opportunities and challenges,” Radiographics, Vol. 27, No. 5, pp. 1445-1462, 2007.   DOI
10 J. Y. Jung, Y. C. Yoon, H. R. Kim, B. K. Choe, J. H. Wang, J. Y. Jung, “Knee derangements: comparis on of isotropic 3D fast spin-echo, isotropic 3D balanced fast field-echo, and conventional 2D fast spin-echo MR imaging,” Radiology, Vol. 268, No. 3, pp. 802-813, 2013.   DOI
11 K. J. Chang, I. R. Kamel, K. J. Macura, D. A. Bluemke, “3.0-T MR imaging of the abdomen: comparison with 1.5T,” Radiographics, Vol. 28, No. 7, pp. 1983-1998, 2008.   DOI
12 Y. Ishimori, M. Monma, Y. Kohno, “Artifact reduction of susceptibility-weighted imaging using a short-echo phase mask,” Acta Radiology, Vol. 50, No. 9, pp. 1027-1034, 2009.   DOI
13 S. J. Bawden, M. C. Stephenson, E. Ciampi, K. Hunter, L. Marciani, I. A. Macdonald, G. P. Aithal, P. G. Morris, P. A. Gowland, “Investigating the effects of an oral fructose challenge on hepatic ATP reserves in healthy volunteers: A (31)P MRS study,” ClinNutr., Vol. 35, No. 3, pp. 645-649, 2015.
14 N. A. Husni, M. T. Islam, Mohammad R. I. Faruque, and N. Misran, "Effects of Electromagnetic Absorption to-Wards human Head due to Variation of Its Dielectric properties at 900, 1800MHz with Different Antenna Substrates," Progress In Electromagnetics Research, Vol. 138, No. 1, 367-388, 2013.   DOI
15 A. Stadlbauer, W. van der Riet, G. Crelier, E. Salo monowitz, "Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and k-tBLAST," Eur J Radiol., Vol. 75, No. 1, pp. e15-21, 2010.   DOI