• Title/Summary/Keyword: Data Accuracy

Search Result 11,880, Processing Time 0.042 seconds

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

A Comparative Analysis between Photogrammetric and Auto Tracking Total Station Techniques for Determining UAV Positions (무인항공기의 위치 결정을 위한 사진 측량 기법과 오토 트래킹 토탈스테이션 기법의 비교 분석)

  • Kim, Won Jin;Kim, Chang Jae;Cho, Yeon Ju;Kim, Ji Sun;Kim, Hee Jeong;Lee, Dong Hoon;Lee, On Yu;Meng, Ju Pil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.553-562
    • /
    • 2017
  • GPS (Global Positioning System) receiver among various sensors mounted on UAV (Unmanned Aerial Vehicle) helps to perform various functions such as hovering flight and waypoint flight based on GPS signals. GPS receiver can be used in an environment where GPS signals are smoothly received. However, recently, the use of UAV has been diversifying into various fields such as facility monitoring, delivery service and leisure as UAV's application field has been expended. For this reason, GPS signals may be interrupted by UAV's flight in a shadow area where the GPS signal is limited. Multipath can also include various noises in the signal, while flying in dense areas such as high-rise buildings. In this study, we used analytical photogrammetry and auto tracking total station technique for 3D positioning of UAV. The analytical photogrammetry is based on the bundle adjustment using the collinearity equations, which is the geometric principle of the center projection. The auto tracking total station technique is based on the principle of tracking the 360 degree prism target in units of seconds or less. In both techniques, the target used for positioning the UAV is mounted on top of the UAV and there is a geometric separation in the x, y and z directions between the targets. Data were acquired at different speeds of 0.86m/s, 1.5m/s and 2.4m/s to verify the flight speed of the UAV. Accuracy was evaluated by geometric separation of the target. As a result, there was an error from 1mm to 12.9cm in the x and y directions of the UAV flight. In the z direction with relatively small movement, approximately 7cm error occurred regardless of the flight speed.

Prediction on the Quality of Total Mixed Ration for Dairy Cows by Near Infrared Reflectance Spectroscopy (근적외선 분광법에 의한 국내 축우용 TMR의 성분추정)

  • Ki, Kwang-Seok;Kim, Sang-Bum;Lee, Hyun-June;Yang, Seung-Hak;Lee, Jae-Sik;Jin, Ze-Lin;Kim, Hyeon-Shup;Jeo, Joon-Mo;Koo, Jae-Yeon;Cho, Jong-Ku
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.29 no.3
    • /
    • pp.253-262
    • /
    • 2009
  • The present study was conducted to develop a rapid and accurate method of evaluating chemical composition of total mixed ration (TMR) for dairy cows using near infrared reflectance spectroscopy (NIRS). A total of 253 TMR samples were collected from TMR manufacturers and dairy farms in Korea. Prior to NIR analysis, TMR samples were dried at $65^{\circ}C$ for 48 hour and then ground to 2 mm size. The samples were scanned at 2 nm interval over the wavelength range of 400-2500 nm on a FOSS-NIR Systems Model 6500. The values obtained by NIR analysis and conventional chemical methods were compared. Generally, the relationship between chemical analysis and NIR analysis was linear: $R^2$ and standard error of calibration (SEC) were 0.701 (SEC 0.407), 0.965 (SEC 0.315), 0.796 (SEC 0.406), 0.889 (SEC 0.987), 0.894 (SEC 0.311), 0.933 (SEC 0.885) and 0.889 (SEC 1.490) for moisture, crude protein, ether extract, crude fiber, crude ash, acid detergent fiber (ADF) and neutral detergent fiber (NDF), respectively. In addition, the standard error of prediction (SEP) value was 0.371, 0.290, 0.321, 0.380, 0.960, 0.859 and 1.446 for moisture, crude protein, ether extract, crude fiber, crude ash, ADF and NDF, respectively. The results of the present study showed that the NIR analysis for unknown TMR samples would be relatively accurate. Use of the developed NIR calibration curve can obtain fast and reliable data on chemical composition of TMR. Collection and analysis of more TMR samples will increase accuracy and precision of NIR analysis to TMR.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

The Diagnostic Value of 99mTc DMSA Renal Scan SPECT Images in Addition to Planar Image in Children with Urinary Tract Infection (소아 요로 감염에서 99mTc DMSA 신스캔 평면영상에 추가된 SPECT 영상의 진단적 가치)

  • Yang Jea-Young;Yang Jung-An;Seo Jung-Wan;Lee Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.22-29
    • /
    • 2001
  • Purpose : 99mTc DMSA renal scan have been widely used not only for tile evaluation of renal scars but also for the diagnosis of acute pyelonephritis. Recent studies have shown SPECT images have higher accuracy than the planar images with some controversy. We evaluated the availability of the SPECT images adding to planar images for the diagnosis of acute pyelonephritis(APN) and renal scar in children with urinary tract infection (UTI). Methods : 130 children with UTI (260 kidney units) and 22 follow-up children (44 kidney units) were included between January 1, 1997 and July 31, 1999 at Ewha University Mokdong Hospital. Planar Anterior and posterior images and SPECT axial and coronal images of 99mTc DMSA renal scan were obtained with Starcam 4000-i U.S.A. GE at 3 hours after 99mTc DMSA I.V. injection. The data were analyzed by Chi square test after Yates's correction. Results : The detection rate of the acute pyelonephritis by SPECT images was 12.3$\%$ higher than that of planar images ($47.7\%\;vs\;35.4\%$) by the patient and 6.9$\%$ higher also ($31.9\%\;vs\;25.4\%$) by the kidney unit. 18 kidney units with negative planar images had focal defect in 10 kidney units (3.8$\%$) and multifocal defect in 8 kidney units (3.1$\%$) on SPECT images, but 1 kidney unit with positive planar image had negative SPECT image. SPECT images were superior to tile planar images in 17.3$\%$. identical in 82.3$\%$ and inferior in 0.4$\%$ to planar image. The detection rate of tile renal scars by SPECT images was 13.7$\%$ higher than planar images by the patient ($68.2\%\;vs\;54.5\%$) and 6.8$\%$ higher also ($43.2\%\;vs\;36.4\%$) by the kidney unit. SPECT images were superior to the planar images in 17.3$\%$ and identical in 82.3$\%$ to planar image. Conclusion SPECT images had shown higher detection rate and better image than planar images for the diagnosis of the acute pyelonephritis and the evaluation of the renal scars. (J. Korean Soc Pediatr Nephrol 5 : 22- 9, 2001)

  • PDF

A Study on the Simplification of Questionnaire for Sasang Constitution Classification(QSCC II) (사상체질진단검사(QSCC II) 설문지 간소화 연구)

  • Park, Jee-Won;Kim, Jeong-Ah;Wang, Myung-Ja
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.334-350
    • /
    • 2003
  • The purpose of this descriptive study was to evaluate the clinical validity of QSCCII (Questionnaire for the Sasang Constitution Classification), whose high accuracy as a constitutional diagnostic tool has been recognized by medical professionals. The subjects of this study were 568 clients from an A university hospital in Suwon. Of the subjects, 259 were health center visitors and 292 were ambulatory clinic visitors. Data were collected using self-reported questionnaire and were analyzed by $X^2$-test and one-way ANOVA. The results of this study as follows: 1. In 4 types of constitution, Soeumin type was found in 41.5% of the subjects. Taeumin type in 39.2%.,and Soyangin type in 19.2%, respectively. There was no Tayangin type found in this study. There were no significant differences on types of constitution by demographic characteristics such as age, sex, marital status, education, religion, and economic status. 2. As for 15 item-selective questionnaire, there were statistically significant differences on the response rate of the 12 items, except items such as A4, A11 and A14, by the types of constitution. When the subjects' own criteria on their constitution were compared to the given constitutional criteria on each item, 4 items such as A6, A11, A13 and A14 were advisable to be excluded from the questionnaire or to be reunited to the other criteria. In the meanwhile, 3 items such as A7, A18 and A15 were desirable to be re-categorized to the other constitutional types and reconstructed to the QSCC II questionnaire. 3. In terms of 106 true-false questionnaire, there were statistically significant differences on the response rate of 46 items by the types of constitution. The 46 items include 15 items (32.6%) of the domain of 'handling something/strength and weakness', 4 items (8.7%) of the domain of 'interpersonal relationship', 9 items (19.6%) of the domain of 'state of mind at ordinary times', 2 items (4.3%) of the domain of 'distinctive emotional characteristics' area, 11 items (23.9%) of the domain of 'specific behavioral trait' and 5 items (10.9%) of the domain of 'physical characteristics'. Therefore, the areas of 'handling something/strength and weakness' and' specific behavioral trait' mainly contributed to the classification of constitutional type. 4. When the 106 true-false items were simplified to the 46 items, statistically significant differences were found on the rate of items allocated to the 3 types of constitution. The rate of selection assigned to the 3 constitutional types of the simplified 46-item questionnaire was higher than that of the original 106-item questionnaire. Conclusions; It was concluded that the rate of selection of each lay person about his own constitutional type would be still higher even though the simplified items of QSCC II questionnaire were applied. If more replicated studies are conducted on the diverse population using the simplifying QSCC II questionnaire in the future, a more simplified standardized Sasang Constitution Questionnaire that is available to the public rather than to medical staffs in the clinical settings could be developed. Moreover, the simplified scale will help nurses deliver more efficient nursing care by providing a more rapid way of health assessment.

  • PDF

NIRS AS AN ESSENTIAL TOOL IN FOOD SAFETY PROGRAMS: FEED INGREDIENTS PREDICTION H COMMERCIAL COMPOUND FEEDING STUFFS

  • Varo, Ana-Garrido;MariaDoloresPerezMarin;Cabrera, Augusto-Gomez;JoseEmilioGuerrero Ginel;FelixdePaz;NatividadDelgado
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1153-1153
    • /
    • 2001
  • Directive 79/373/EEC on the marketing of compound feeding stuffs, provided far a flexible declaration arrangement confined to the indication of the feed materials without stating their quantity and the possibility was retained to declare categories of feed materials instead of declaring the feed materials themselves. However, the BSE (Bovine Spongiform Encephalopathy) and the dioxin crisis have demonstrated the inadequacy of the current provisions and the need of detailed qualitative and quantitative information. On 10 January 2000 the Commission submitted to the Council a proposal for a Directive related to the marketing of compound feeding stuffs and the Council adopted a Common Position (EC N$^{\circ}$/2001) published at the Official Journal of the European Communities of 2. 2. 2001. According to the EC (EC N$^{\circ}$ 6/2001) the feeds material contained in compound feeding stufs intended for animals other than pets must be declared according to their percentage by weight, by descending order of weight and within the following brackets (I :< 30%; II :> 15 to 30%; III :> 5 to 15%; IV : 2% to 5%; V: < 2%). For practical reasons, it shall be allowed that the declarations of feed materials included in the compound feeding stuffs are provided on an ad hoc label or accompanying document. However, documents alone will not be sufficient to restore public confidence on the animal feed industry. The objective of the present work is to obtain calibration equations fur the instanteneous and simultaneous prediction of the chemical composition and the percentage of ingredients of unground compound feeding stuffs. A total of 287 samples of unground compound feeds marketed in Spain were scanned in a FOSS-NIR Systems 6500 monochromator using a rectangular cup with a quartz window (16 $\times$ 3.5 cm). Calibration equations were obtained for the prediction of moisture ($R^2$= 0.84, SECV = 0.54), crude protein ($R^2$= 0.96, SECV = 0.75), fat ($R^2$= 0.86, SECV = 0.54), crude fiber ($R^2$= 0.97, SECV = 0.63) and ashes ($R^2$= 0.86, SECV = 0.83). The sane set of spectroscopic data was used to predict the ingredient composition of the compound feeds. The preliminary results show that NIRS has an excellent ability ($r^2$$\geq$ 0, 9; RPD $\geq$ 3) for the prediction of the percentage of inclusion of alfalfa, sunflower meal, gluten meal, sugar beet pulp, palm meal, poultry meal, total meat meal (meat and bone meal and poultry meal) and whey. Other equations with a good predictive performance ($R^2$$\geq$0, 7; 2$\leq$RPD$\leq$3) were the obtained for the prediction of soya bean meal, corn, molasses, animal fat and lupin meal. The equations obtained for the prediction of other constituents (barley, bran, rice, manioc, meat and bone meal, fish meal, calcium carbonate, ammonium clorure and salt have an accuracy enough to fulfill the requirements layed down by the Common Position (EC Nº 6/2001). NIRS technology should be considered as an essential tool in food Safety Programs.

  • PDF

Dose Verification Study of Brachytherapy Plans Using Monte Carlo Methods and CT Images (CT 영상 및 몬테칼로 계산에 기반한 근접 방사선치료계획의 선량분포 평가 방법 연구)

  • Cheong, Kwang-Ho;Lee, Me-Yeon;Kang, Sei-Kwon;Bae, Hoon-Sik;Park, So-Ah;Kim, Kyoung-Joo;Hwang, Tae-Jin;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • Most brachytherapy treatment planning systems employ a dosimetry formalism based on the AAPM TG-43 report which does not appropriately consider tissue heterogeneity. In this study we aimed to set up a simple Monte Carlo-based intracavitary high-dose-rate brachytherapy (IC-HDRB) plan verification platform, focusing particularly on the robustness of the direct Monte Carlo dose calculation using material and density information derived from CT images. CT images of slab phantoms and a uterine cervical cancer patient were used for brachytherapy plans based on the Plato (Nucletron, Netherlands) brachytherapy planning system. Monte Carlo simulations were implemented using the parameters from the Plato system and compared with the EBT film dosimetry and conventional dose computations. EGSnrc based DOSXYZnrc code was used for Monte Carlo simulations. Each $^{192}Ir$ source of the afterloader was approximately modeled as a parallel-piped shape inside the converted CT data set whose voxel size was $2{\times}2{\times}2\;mm^3$. Bracytherapy dose calculations based on the TG-43 showed good agreement with the Monte Carlo results in a homogeneous media whose density was close to water, but there were significant errors in high-density materials. For a patient case, A and B point dose differences were less than 3%, while the mean dose discrepancy was as much as 5%. Conventional dose computation methods might underdose the targets by not accounting for the effects of high-density materials. The proposed platform was shown to be feasible and to have good dose calculation accuracy. One should be careful when confirming the plan using a conventional brachytherapy dose computation method, and moreover, an independent dose verification system as developed in this study might be helpful.

Acceleration of computation speed for elastic wave simulation using a Graphic Processing Unit (그래픽 프로세서를 이용한 탄성파 수치모사의 계산속도 향상)

  • Nakata, Norimitsu;Tsuji, Takeshi;Matsuoka, Toshifumi
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.98-104
    • /
    • 2011
  • Numerical simulation in exploration geophysics provides important insights into subsurface wave propagation phenomena. Although elastic wave simulations take longer to compute than acoustic simulations, an elastic simulator can construct more realistic wavefields including shear components. Therefore, it is suitable for exploration of the responses of elastic bodies. To overcome the long duration of the calculations, we use a Graphic Processing Unit (GPU) to accelerate the elastic wave simulation. Because a GPU has many processors and a wide memory bandwidth, we can use it in a parallelised computing architecture. The GPU board used in this study is an NVIDIA Tesla C1060, which has 240 processors and a 102 GB/s memory bandwidth. Despite the availability of a parallel computing architecture (CUDA), developed by NVIDIA, we must optimise the usage of the different types of memory on the GPU device, and the sequence of calculations, to obtain a significant speedup of the computation. In this study, we simulate two- (2D) and threedimensional (3D) elastic wave propagation using the Finite-Difference Time-Domain (FDTD) method on GPUs. In the wave propagation simulation, we adopt the staggered-grid method, which is one of the conventional FD schemes, since this method can achieve sufficient accuracy for use in numerical modelling in geophysics. Our simulator optimises the usage of memory on the GPU device to reduce data access times, and uses faster memory as much as possible. This is a key factor in GPU computing. By using one GPU device and optimising its memory usage, we improved the computation time by more than 14 times in the 2D simulation, and over six times in the 3D simulation, compared with one CPU. Furthermore, by using three GPUs, we succeeded in accelerating the 3D simulation 10 times.