Upper Body Surface Change Analysis using 3-D Body Scanner

3차원 인체 측정기를 이용한 체표변화 분석

  • Lee Jeongran (Dept. of Clothing & Textiles, Institute of Ecology for the Elderly, Pusan National University) ;
  • Ashdoon Susan P. (Dept, of Textiles & Apparel, Cornell University)
  • 이정란 (부산대학교 의류학과, 노인생활환경연구소) ;
  • Published : 2005.12.01

Abstract

Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

3차원 스캐너를 통한 인체 측정치는 다양한 분야에서 사용되고 있다. 본 연구는 이러한 3차원 측정치의 정확성과 신뢰도를 조사하기 위한 것이다. 이를 위해 TECMATH사의 VITUS 전신 스캐너로 인체를 측정, ScanWorX Body Measure 소프트웨어를 이용하여 항목을 측정 한 값과 직접 인체측정 에 의해 얻어진 값을 비교하였다. 피험자는 평균 체형의 미국 여대생 25명이며 기준 자세와 일상생활에 많이 쓰이는 $135^{\circ}$ 양팔들기, 어깨 구부리기, 어깨 들어올리기의 3가지 동적 자세를 실험 동작으로 하여 체표의 길이 및 둘레의 변화를 측정하였다. 기준 자세와 135"양팔 들기에 대한 측정치 비교에서 두 가지 측정법에 의한 항목들의 차이는 $-2\~20mm$였으나 두 동작 모두에서 목둘레만이 유의한 차이가 있는 것으로 나타났다. 또한 길이항목보다 둘레항목에서 좀 더 큰 차이를 보였다. 실험 동작에 의해 상반신 18개의 측정항목들은 유의한 체표변화를 나타내었으며 특히 어깨길이, 겨드랑앞벽사이길이, 겨드랑뒤벽사이길이 그리고 견봉사이길이에서 뚜렷한 변화가 나타났다. 그러나 두 측정 법에 따른 체표변화 차이는 없었다. 어깨 구부리기와 어깨 들어올리기 동작시에는 스캔 측정을 3회 반복함으로써 3차원 측정치의 신뢰도를 조사하였는데 모든 항목에서 3회 반복된 측정치가 통계적으로 동일한 것으로 나타났다. 또한 ScanWorX소프트웨어의 가상적 도구인 Body Measure와 자동 프로그램인 ScanWorX Tailor의 측정치를 비교한 결과 자동 측정치가 더 큰 값을 보였고 사용한 프로그램에 따른 유의한 차이를 나타내는 항목들이 나타났다. 이상의 결과로 3차원 인체 측정기를 사용함으로써 짧은 시간에 동작을 촬영하고 이에 대한 측정치를 얻을 수 있어 편리함과 신뢰도에 있어서 장점을 가짐을 확인할 수 있었다. 그러나 좀 더 다양한 분석과 정확한 결과를 얻기 위해서는 의복 분야에 유용한 자동 프로그램의 개발과 3차원 인체 측정기간의 호환성의 문제들이 요구된다고 할 수 있다.

Keywords

References

  1. Aldrich, W., Smith, B., & Dong, F. (1998). Obtaining repeatability of natural extended upper body positions. Journal of Fashion Marketing and Management, 2(4), 329-351 https://doi.org/10.1108/eb022538
  2. Brunsman, M. A., Dannen, H., Robinette, K. M. (1997). Optimal postures and positioning for human body scanning. Proceedings of International Conference on Recent Advance in 3D Digital Imaging and Modeling, 266-273
  3. Yu, C. Y., Lo, Y. H., & Chiou, W. K. (2003). The 3D scanner for measuring body surface area. Applied Ergonomics, 34, 273-278 https://doi.org/10.1016/S0003-6870(03)00007-3
  4. Dannen, H. A., Brunsman, M. A., & Robinette, K. M. (1997). Reducing movement artifacts in whole body scanning. Proceedings of International Conference on Recent Advance in 3D Digital Imaging and Modeling. 262-265
  5. Feathers, D. J., Paquet, V. L., & Drury, C. G. (2003). Measurement consistency and three-dimensional electromechanical anthropometry, International Journal of Industrial Ergonomics, 33, 181-190
  6. Bougourd, J. P., Dekker, L., Ross, P. G., & Ward, J. P. (2000). A Comparison of Women's Sizing by 3D Electronic Scanning and Traditional Anthropometry. Journal of Textile Institute, 91 Part 2(2), 163-173 https://doi.org/10.1080/00405000008659536
  7. Brooke-Wavell, K., Jones, P. R. M., & West, G. M. (1994). Reliability and repeatability of 3-D body scanner (LASS) measurements compared to anthropometry. Annals of Human Biology, 21(6), 571-577 https://doi.org/10.1080/03014469400003572
  8. Mckinnon, J., & Istook, C. L. (2002). Body scanning, The effects of subject respiration and foot positioning on the data integrity of scanned measurements. Journal of Fashion Marketing and Management, 6(2), 103-121 https://doi.org/10.1108/13612020210429458
  9. Lee, J. Y., Joo, S. Y., & Ashdown, S. P. (2004). A basic study contributes to extract the standardized 3D body data for women aged 60 and older. Journal of the Korean Society of Clothing and Textiles, 28(2), 344-353
  10. Park, S. M., Nam, Y. J., & Choi, K. M. (2004). A basic study for the standardization of 3D anthropometry. Proceedings of Korean Society of Clothing and Textiles, 57
  11. Trieb, R., Seidl, A., Hansen, G., & Prutt, C. (2000), 3-D Body scanning-systems, methods and applications for automatic interpretation of 3D surface anthropometrical data. Proceedings of the IEA 2000/HFES 2000 Congress, 843-846
  12. Ashdown, S. P., & Locker, S. (2004). Improved apparel sizing: Fit and anthropometric 3D scan data. National Textile Center Annual Report
  13. Williamson, D., Kahn, H., Burnette, C., & Russell, C. (1997). Precision of recumbent anthropometry. American Journal of Epidemiology, 15, 159-167