• Title/Summary/Keyword: Dap-ho

Search Result 49, Processing Time 0.034 seconds

Performance Evaluation of Domestic Prototype Dose Area Product Meter SFT-1 (국산 프로토타입 면적선량계 SFT-1의 성능평가)

  • Lee, Ho-Sun;Han, Seong-Gyu;Roh, Young-Hoon;Lim, Hyun-Jong;Kim, Jung-Min;Kim, Jong-Uk;Chae, Hyun-Sik;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.435-441
    • /
    • 2016
  • The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R&BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatability coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria.

Development of Enhanced DAP(Dose Area Product) (성능이 향상된 면적선량계(DAP) 개발)

  • Lee, Young-Ji;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.739-742
    • /
    • 2019
  • In this paper, we propose enhanced DAP(Dose Area Product). The development of enhanced DAP proposed in this paper has optimized the area dose meter that was developed previously. The development of enhanced DAP performed Optimized design of charge integrator and ADC circuit, optimization of line transceiver for RS-485 communication, optimization of display circuit, and optimization of PC-based control program for interlocking and aging. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, Radiation dose dependence and Radiation quality dependence were measured to be 4.2%, which is below ${\pm}15%$ of international standard. Energy range/Tube voltage was confirmed in the range of 30~150kV. The sensitivity difference between sensor field and sensor field area dose sensitivity was measured to be 4.3%, and it was confirmed that it operates normally under ${\pm}15%$ of international standard. In order to measure the reproducibility of the area dosimeter, it was confirmed that it was 0% and it was operated normally at less than 2% of IEC60580 recommendation. Digital resolution was confirmed to be a minimum unit of $0.01{\mu}Gy{\cdot}m^2$ within the error range for the reference dose per hour.

Isolation and Identification of Actinomycetes F-97 Producing Tyrosinase Inhibitor (Tyrosinase 저해제를 생성하는 방선균 F-97의 분리 및 동정)

  • Bang, Byung-Ho;Rhee, Moon-Soo;Kim, Gwan-Pil;Kim, Jin-O;Yi, Dong-Heui
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.1
    • /
    • pp.97-102
    • /
    • 2009
  • In order to obtain a non-toxic and more active and stable microorganism-produced tyrosinase inhibitor, we isolated actinomycetes F-97, a producer of tyrosinase inhibitor, from soil. The aerial hyphae of this strain were gray in color with tree types. Under the microscopic examination, the isolate formed a spiral aerial spore mass with a smooth surface. The analysis of cell wall acid hydrolysate of the isolate revealed the presence of LL-diaminopimelic acid(LL-DAP). No specific sugar was detected. From these results and the cultural and physiological characteristics described in the Bergey's Manual, actinomycetes F-97 was identificated as, or best-matched to, Streptomyces aburaviensis.

Antimicrobial activity and tumor cell growth inhibition of an Actinomycete isolated from Korean soil (토양에서 분리한 방선균의 항균력 및 암세포주 성장 억제능)

  • Han, Jin-HO;Kim, Seung-Cheol;Chang, Young-Soo;Ryeom, Kon
    • YAKHAK HOEJI
    • /
    • v.37 no.4
    • /
    • pp.389-396
    • /
    • 1993
  • An Actinomycetes strain JB isolated from Mt. Hanla had a strong antimicrobial activity against gram positive bacteria and tumor cell growth inhibition. Especially, it couldn't degrade starch and casein as organic compounds. It was resist on lincomycin and rifampicin. The spore mass of strain JB which was arethrospore was white. DAP of the cell wall was L, L-DAP. Antimicrobial material was heat stable, dissolved in ethyl acetate, and not dissolved in butanol. In the pressnce of 0.1% phenol and 4% sodium chloride, strain JB could grow, but it didn't growth at below $10^{\circ}C$. Strain JB didn't use dextran, sodium acetate and sodium citrate as sole carbon source and L-cystein and L-thereonine as nitrogen source. The filtered broth of strain JB had the antimicrobial activity against gram positive bacteria, especially Staphylococcus aureus (ATCC 65389) and the growth inhibition of tumor cell line.

  • PDF

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

Effects of Altitude and Planting Time on Tuber Bulking of Potato (감자 고랭지 재배 시 표고 및 파종시기에 따른 괴경의 비대반응)

  • Kim, Chung-Guk;Ok, Hyun-Chung;Jeong, Jin-Chol;Hur, On-Sook;Seo, Jong-Ho;Jeong, Kwang-Ho;Kim, Si-Ju
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.4
    • /
    • pp.418-423
    • /
    • 2012
  • Field experiments were carried out to improve the cultural practice of potato by analysing its tuberization patterns. Tuberization patterns affected by different altitudes was analyzed at two potato cultivation regions, Jinbu (600 m) and Daegwallyung (800 m) using two potato cultivars, 'Superior' and 'Atlantic'. To analyse tuberization patterns affected by different planting time, seed potatoes were planted at every 10 days from April 19 to May 19 in Daegwallyung. Total dry weight was greater in plant grown at the altitude of 800 m than 600 m during the entire growth period and the highest increase was observed at the early growth period, July 6, comparing to other growth period. The total dry weight was the greatest at 110~112 days after planting (DAP) at the altitude of 800 m and 108~111 DAP at 600 m. There was no significant differences between altitudes and between cultivars. Tuber dry weight per plant at the altitude of 600 m was lower than 800 m on July 6 (58 DAP), but it increased rapidly from July 21 (73 DAP). At both altitudes, the increase of tuber dry weight per plant from July 6 to August 8 was higher than the other growth period. The time of growth period at which tuber dry weight per plant was the highest was similar at both altitudes that was 118~125 DAP at the altitude 800 m and 118~124 DAP at the altitude 600 m. Dry weight per tuber at the altitude 800m was higher than 600 m due to the number of tubers per plant. A higher increase of crop growth rate (CGR) was shown at the altitude 600 m on July 6 (58 DAP), comparing to at 800 m. The highest tuber dry weight per plant of each cultivar was shown when the planting time was April 29 for 'Superior' and was April 19 for 'Atlantic'. Both the tuber dry weight of plant and the total dry weight were lower at a later planting time. Dry weight per tuber increased quickly during the period between June 30 to August 8. Tuberization period was shortened as the planting time was delayed.

Gonadal Development and Sex Ratio of Artificial Seedlings of the Oblong Rockfish Sebastes oblongus (황점볼락 Sebastes oblongus 인공종묘의 생식소 발달과 성비)

  • Kwak Eun-Joo;Lee Kyung-Wo;Choi Nak-Hyun;Park Chung-Kug;Han Kyeong-Ho;Lee Won-Kyo;Yang Seok-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.3
    • /
    • pp.297-302
    • /
    • 2006
  • We investigated gonadal development and sex ratio of artificial seedlings of the oblong rockfish Sebastes oblongus, based on samplings for 370 days just after parturition. The primordial germ cells and genital ridge appeared separately under the mesentery in the yolk-sac stage larva (total length: 7.10-7.77 mm) just after parturition. The primordial germ cells and genital ridge integrated to form primordial gonad in 5-day-old larvae (7.12-9.68 mm), and then proliferation of somatic cell and germ cell occurred in the gonad, which was maintained undifferentiated until 45-days after parturition (18.6-20.4 mm). The ovarian differentiation began in the larva of 50-days old (dab) after parturition (dap) (20.0-24.5 mm). The somatic tissues elongated from the both opposite end-sites of undifferentiated gonad were consequently fused and formed a complete ovarian cavity at 60-days old dap (25.5-32.0 mm). In 80-days old dap (37.3-47.2 mm), meiosis of oogonia occurred to be chromatin nucleolus stage oocyte. The perinucleolus stage oocytes appeared at in 130-days old dap (68.0-86.0 mm), and previtellogenic stage oocytes appeared in 370-days old dap (101.0-116.0 mm). Only female was observed in the artificially produced oblong rockfish in the present study. This result revealed the effect of higher temperature on the sex determination of the oblong rockfish..

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Effect of Ethylene Removal on Fruit Quality of Oriental Pear during Storage (저장고 내의 에틸렌 제거가 배 과실의 품질에 미치는 영향)

  • Kim Ho-Cheol;Bae Kang-Soon;Bae Jong-Hyang;Jeon Kyung-Soo;Hong Jong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.15 no.1
    • /
    • pp.78-83
    • /
    • 2006
  • The objective of this study was to examine effect of ethylene removal apparatus on fruit quality of 'Niitaka' pear (Pyrus pyrifolia) in case of a double storage of apples and pears in a storage room. Ethylene and carbon dioxide concentration were efficiently decreased by the ethylene removal apparatus. Fruit weight loss was high at double storage of apples and pears (DAP) in a storage room compared with storage of pears. Fruit core browning was $5{\sim}22.5%$ at the fruits in DAP, but as setting ethylene removal apparatus it was not occurred till 90 days after storage. Soluble solids content and fruit peel hardness were not different among the treatments. Accordingly, a double storage of apples and pears in a storage room is possible as setting ethylene removal apparatus.

Investigation on the Excitonic Luminescence Properties of ZnO Bulk Crystal (ZnO 기판의 불순물 속박 엑시톤 발광을 이용한 물성 분석)

  • Choi, Jun Seck;Ko, Dong Wan;Jeong, Min Ji;Lee, Sang Tae;Chang, Ji Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.196-200
    • /
    • 2019
  • In this study, photoluminescence (PL) analysis was performed to evaluate the optical properties of commercial ZnO substrates. Particular attention was paid to the bound exciton (BX) luminescence, which is usually the strongest emission intensity of commercial substrates. At 15 K, PL analysis revealed that the BX peak due to donor-type impurities (donor-bound-exciton; DX) dominated, while two-electron satellite (TES) emission, donor-accepter pair (DAP) emission, and LO-phonon replica emission were also observed. The impurity concentration of the ZnO substrate was determined to be $10^{15}$ to $10^{16}/cm^3$ by examination of the temperature variation of DAP, while the half width and intensity change of the luminescence revealed that the temperature change of BX can be interpreted almost the same as the analysis of free-exciton emission.