• 제목/요약/키워드: Damage rates

검색결과 534건 처리시간 0.037초

Front-end investigations of the coated particles of nuclear fuel samples - ion polishing method

  • Krajewska, Zuzanna M.;Buchwald, Tomasz;Tokarski, Tomasz;Gudowski, Wacław
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.1935-1946
    • /
    • 2022
  • The investigations of the coated-particles of nuclear fuel samples are carried out in three stages: front-end, irradiation in the reactor core, and post-irradiation examination. The front-end stage is the initial analysis of the failures rates of produced samples before they are placed in the reactor core. The purpose of the verification is to prepare the particles for an experiment that will determine the degree of damage to the coated particles at each stage. Before starting experiments with the samples, they must be properly prepared. Polishing the samples in order to uncover the inner layers is an important, initial experimental step. The authors of this paper used a novel way to prepare samples for testing - by applying an ion polisher. Mechanical polishing used frequently for sample preparations generates additional mechanical damages in the studied fuel particle, thus directly affecting the experimental results. The polishing methods were compared for three different coated particles using diagnostic methods such as Raman spectroscopy, scanning electron microscopy, and confocal laser scanning microscopy. Based on the obtained results, it was concluded that the ion polishing method is better because the level of interference with the structures of the individual layers of the tested samples is much lower than with the mechanical method. The same technique is used for the fuel particles undergone ion implantation simulating radiation damage that can occur in the reactor core.

화재피해를 받은 철근콘크리트 건축물의 기둥의 영향인자를 고려한 해석적 연구 (Numerical Study on the Fire Damaged Reinforced Concrete Building Structures Considering Influencing Fire Case and Parameters of Columns)

  • 서연우;손희주
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.101-112
    • /
    • 2022
  • Expanding urbanization practices result in high numbers of buildings being developed in city centers. This high building concentration leads to an increased fire risk, resulting in higher casualty rates and increased economic damages compared to fires in the past. The purpose of this study was to analyze the structural behavior of fire-damaged reinforced concrete buildings using analytical methods and to suggest methods of improving fire resistance in the event of a fire. Damage levels were measured using commercial software to apply the finite element method, ABAQUS, and MIDAS GEN to the dataset. Load-deflection curves were calculated using the effective area and moment of inertia of the fire-damaged columns provided by ABAQUS. The results of this analysis indicate that fire-damaged beams with experience greater deflection from indoor fires than they will from outdoor fires. Fires that occurred on the middle floors were more dangerous than those occurring on higher floors, and eccentrically loaded columns experienced more damage than axially loaded columns. The results indicate that these methods accurately predict structural behaviors of fire damaged concrete columns by considering fire exposure area and eccentric loading.

Structural health monitoring for pinching structures via hysteretic mechanics models

  • Rabiepour, Mohammad;Zhou, Cong;Chase, James G.;Rodgers, Geoffrey W.;Xu, Chao
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.245-258
    • /
    • 2022
  • Many Structural Health Monitoring (SHM) methods have been proposed for structural damage diagnosis and prognosis. However, SHM for pinched hysteretic structures can be problematic due to the high level of nonlinearity. The model-free hysteresis loop analysis (HLA) has displayed notable robustness and accuracy in identifying damage for full-scaled and scaled test buildings. In this paper, the performance of HLA is compared with seven other SHM methods in identifying lateral elastic stiffness for a six-story numerical building with highly nonlinear pinching behavior. Two successive earthquakes are employed to compare the accuracy and consistency of methods within and between events. Robustness is assessed across sampling rates 50-1000 Hz in noise-free condition and then assessed with 10% root mean square (RMS) noise added to responses at 250 Hz sampling rate. Results confirm HLA is the most robust method to sampling rate and noise. HLA preserves high accuracy even when the sampling rate drops to 50 Hz, where the performance of other methods deteriorates considerably. In noisy conditions, the maximum absolute estimation error is less than 4% for HLA. The overall results show HLA has high robustness and accuracy for an extremely nonlinear, but realistic case compared to a range of leading and recent model-based and model-free methods.

증기발생기 튜브재질의 미끄럼 마멸 및 프레팅 마멸 특성 (Sliding Wear and Fretting Wear of Steam Generator Tube Materials)

  • 김동구;조정우;이영제
    • Tribology and Lubricants
    • /
    • 제17권5호
    • /
    • pp.380-385
    • /
    • 2001
  • In nuclear power steam generators, high flow rates can induce vibration of the tubes resulting in fretting wear damage due to contacts between the tubes and their supports. In this paper the fretting wear tests and the sliding wear tests were performed using the steam generator tube materials of Inconel 600 and 690 against STS 304. Sliding tests with the pin-on-disk type tribometer were done under various applied loads and sliding speeds at air environment. Fretting tests were done under various vibrating amplitudes and applied normal loads. From the results of sliding and fretting wear tests, the wear of Inconel 600 and 690 can be predictable using the work rate model. Depending on normal loads and vibrating amplitudes, distinctively different wear mechanisms and often drastically different wear rates can occur. It was found the results that the wear coefficients for Inconel 600 and 690 were 262.3$\times$10$\^$-15/Pa$\^$-1/ and 209.2$\times$10$\^$-15/Pa$\^$-1/, respectively. This study shows that Inconel 690 can provide much better wear resistance than Inconel 600 in air.

Compressive behavior of concrete under high strain rates after freeze-thaw cycles

  • Chen, Xudong;Chen, Chen;Liu, Zhiheng;Lu, Jun;Fan, Xiangqian
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.209-217
    • /
    • 2018
  • The dynamic compressive behavior of concrete after freezing and thawing tests are investigated by using the split Hopkinson pressure bar (SHPB) technique. The stress-strain curves of concrete under dynamic loading are measured and analyzed. The setting numbers of freeze-thaw cycles are 0, 25, 50, and 75 cycles. Test results show that the dynamic strength decreases and peak strain increases with the increasing of freeze-thaw cycles. Based on the Weibull distribution model, statistical damage constitutive model for dynamic stress-strain response of concrete after freeze-thaw cycles was proposed. At last, the fragmentation test of concrete subjected to dynamic loading and freeze-thaw cycles is carried out using sieving statistics. The distributions of the fragment sizes are analyzed based on fractal theory. The fractal dimensions of concrete increase with the increasing of both freeze-thaw cycle and strain rate. The relations among the fractal dimension, strain rates and freeze-thawing cycles are developed.

다공성 금속 샤워헤드가 적용된 상압플라즈마 화학기상증착법을 이용한 저온 다결정 실리콘 증착 공정 (Low Temperature Polycrystalline Silicon Deposition by Atmospheric Pressure Plasma Enhanced CVD Using Metal Foam Showerhead)

  • 박형규;송창훈;오훈정;백승재
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.344-349
    • /
    • 2020
  • Modern thin film deposition processes require high deposition rates, low costs, and high-quality films. Atmospheric pressure plasma-enhanced chemical vapor deposition (AP-PECVD) meets these requirements. AP-PECVD causes little damage on thin film deposition surfaces compared to conventional PECVD. Moreover, a higher deposition rate is expected due to the surface heating effect of atomic hydrogens in AP-PECVD. In this study, polycrystalline silicon thin film was deposited at a low temperature of 100℃ and then AP-PECVD experiments were performed with various plasma powers and hydrogen gas flow rates. A deposition rate of 15.2 nm/s was obtained at the VHF power of 400 W. In addition, a metal foam showerhead was employed for uniform gas supply, which provided a significant improvement in the thickness uniformity.

Analysis of the Inhibitory Effect of two Bacterial Strains on Metarhizium anisopliae Induced Fatality Rates in Protaetia Brevitarsis

  • Kwak, Kyu-Won;Nam, Sung-Hee;Park, Kwan-Ho;Lee, Heuisam;Han, Myung-Sae
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제37권1호
    • /
    • pp.9-14
    • /
    • 2018
  • Bacterial species, Bacillus amyloliquefaciens and Lactobacillus species (L. sp.5-1), are known to inhibit the growth of pathogenic bacteria and fungi. Metarhizium anisopliae is a pathogenic fungal species which causes fatal damage to P. brevitarsis populations. Therefore, we investigated the inhibitory effect of B. amyloliquefaciens and L. sp. 5-1 on M. anisopliae induced fatality rates in P. brevitarsis. Samples of M. anisopliae-infected sawdust were treated with strain B. amyloliquefaciens KACC10116, strain L. sp. 5-1 KACC19351, and a combination of the two. P. brevitarsis were fed treated sawdust samples, and their subsequent fatality rate was monitored. The fatality rate fell below 1.5% after 10 days and decreased by approximately 40% after 15 days. On average, the fatality rate decreased by 20%, compared to the control. The difference in the decrease in fatality rate between B. amyloliquefaciens treatment and L. sp. 5-1 treatment was not significant. Results indicate that both strains exhibit high anti-fungal activity, which may be useful in environmental purification efforts. These strains may be used for effective prevention of fungal infection in P. brevitarsis.

변형률 속도에 따른 EPP Foam의 대변형 동적 압축 특성에 관한 연구 (High Strain Rate Compression Behavior of EPP Bumper Foams)

  • 최기상;강우종;김기훈;김성근
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.118-125
    • /
    • 2009
  • Bumper is designed to protect the automotive frame without damage at low velocity. Expanded polypropylene (EPP) foam is used in the bumper as an energy absorbing material. In order to exactly predict the energy absorbing performance of the foam material under impact loading condition, it is important to use high strain rate material properties. In this study, a new apparatus for dynamic compression tests was developed to investigate the high strain rate behavior of EPP foams. Three kinds of EPP foams which have different expansion ratios were tested to investigate the quasi-static and dynamic compression behavior. Quasi-static compressions were performed at low strain rates of 0.001/s, 0.1/s and 1/s. The dynamic compressions were carried out at high strain rates of 50/s and 100/s with the developed apparatus. It was observed that the EPP foam has significant strain rate effect as compared to quasi-static behavior.

Dilatation characteristics of the coals with outburst proneness under cyclic loading conditions and the relevant applications

  • Li, Yangyang;Zhang, Shichuan;Zhang, Baoliang
    • Geomechanics and Engineering
    • /
    • 제14권5호
    • /
    • pp.459-466
    • /
    • 2018
  • By conducting uniaxial loading cycle tests on the coal rock with outburst proneness, the dilatation characteristics at different loading rates were investigated. Under uniaxial loading and unloading, the lateral deformation of coal rock increased obviously before failure, leading to coal dilatation. Moreover, the post-unloading recovery of the lateral deformation was rather small, suggesting the onset of an accelerated failure. As the loading rate increased further, the ratio of the stress at the dilatation critical point to peak-intensity increased gradually, and the pre-peak volumetric deformation decreased with more severe post-peak damage. Based on the laboratory test results, the lateral deformation of the coals at different depths in the #1302 isolated coal pillars, Yangcheng Coal Mine, was monitored using wall rock displacement meter. The field monitoring result indicates that the coal lateral displacement went through various distinct stages: the lateral displacement of the coals at the depth of 2-6 m went through an "initial increase-stabilize-step up-plateau" series. When the coal wall of the working face was 24-18 m away from the measuring point, the coals in this region entered the accelerated failure stage; as the working face continued advancing, the lateral displacement of the coals at the depth over 6 m increased steadily, i.e., the coals in this region were in the stable failure stage.

Study on the Damage by Pine Wood Nematode in Black Pine Trees

  • Ha, Man-Leung;Lee, Chong-Kyu
    • Journal of Forest and Environmental Science
    • /
    • 제33권2호
    • /
    • pp.105-112
    • /
    • 2017
  • The distribution and form of pine wood nematode (PWN) were investigated in Jinju-si and Sacheon-si areas, where infested with pine wilt disease (PWD). The average PWN population per g of the tubulation part in the wilted Japanese balck pine were 381.2 and 341 in Jinju-si and Sacheon-si, respectively. The PWN population per g of affected Japanese black pine with wilt rate below 60% were 556 and 518 in Jinju-si and Sacheon-si, respectively. The ratios of PWN and other plant-parasitic nematode in the wilted Japanse black pines were 48% vs. 52% in Jinju-si and 53% vs. 47% in Sacheon-si after exposure to PWD for 1 year. The survivorship of pine wood nematode in the sampled trees after 1 year was 0-10% in the Jinju-si area and 5-20% detected in the Sacheon-si area. In the forest areas affected by PWN, the highest survival rates were 37.2% and 39.8% at 25 cm diameter at breast height (DBH) in Jinju-si and Sacehon-si, respectively, while the highest wilt rates were 30.5% and 28.3% at 30 cm DBH in Jinju-si and Sacehon-si, respectively.