• 제목/요약/키워드: DVR

검색결과 262건 처리시간 0.035초

DVR 모니터의 동특성 향상을 위한 구조 개선에 관한 연구 (Design Alteration of a Security DVR Monitor Structure for the Improved Dynamic Stabilty)

  • 김건형;이원규;이태훈;노승훈;정평수
    • 한국산업융합학회 논문집
    • /
    • 제13권2호
    • /
    • pp.63-68
    • /
    • 2010
  • Structural vibrations are among the biggest concerns in developing high resolution DVR(Digital Video Recorder) monitors. The vibrations in DVR monitors are mostly originated from the excitation sources such as the HDD and the cooling fan. In this study, the vibrations generated from the excitation sources were investigated in order to analyze the individual effect on the structural vibrations of the monitors and further to establish the design alteration to suppress the vibrations for the stability of the structure and for the better quality of the screen. The result shows that relatively simple design alterations can improve the stability of the structure substantially.

  • PDF

DVR시스템을 위한 저널링 파일시스템의 성능평가 (Performance Test of Journaling File System for DVR System)

  • 권우일;윤미현;이동준;장재혁;양승민
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2002년도 가을 학술발표논문집 Vol.29 No.2 (1)
    • /
    • pp.397-399
    • /
    • 2002
  • 최근 무인 감시 시스템 분야에서 리눅스 기반 DVR(Digital Video Recording)시스템의 사용이 늘어나고 있다. DVR시스템은 기존의 아날로그 비디오영상 기록을 대체하여, 카메라에서 입력받은 아날로그 신호를 디지털화(MPEG또는 MJPEG)된 영상을 하드디스크에 저장하는 방법으로 작동하는 주기적으로 빈번한 하드디스크의 쓰기 작업을 수행한다. 또 기록되는 내용의 특성상 높은 신뢰도가 요구된다. 따라서 저장장치의 신뢰도가 중요하며, 만일의 사태에 발생할 수 있는 시스템 고장에도 저장된 정보의 손실을 최소화해야 한다. 저널링 파일시스템은 이러한 요구사항에 적합한 기능을 갖추고 있으며 최근 사용범위가 넓어지고 있다. 본 논문에서는 리눅스 시스템에서 널리 사용되는 4가지 저널링 파일시스템의 상대적인 읽기, 쓰기 및 복구 성능을 비교 평가하고 이를 바탕으로 고 신뢰도의 DVR시스템에 요구되는 적절한 저널링 파일시스템을 제안한다.

  • PDF

22.9kV 배전선로 적용을 위한 DVR 제어시스템 설계 (DVR Control System Design applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;전영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.30-32
    • /
    • 2004
  • This paper describes control system design for the DH(dynamic voltage restorer) consisted of a diode rectifier and series inverter applied to 22.9kV distribution system. The DVR control system is consisted of the main two parts. One is a voltage event detector using a neural network and the other is deadbeat controller for the output voltage and current control of the DVR. A simulation model was developed for analyzing performance of the controller and the whole system. The results confirm that the DVR can restore load voltage under the fault of the distribution system.

  • PDF

Modeling and Control Design of Dynamic Voltage Restorer in Microgrids Based on a Novel Composite Controller

  • Huang, Yonghong;Xu, Junjun;Sun, Yukun;Huang, Yuxiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1645-1655
    • /
    • 2016
  • A Dynamic Voltage Restorer (DVR) model is proposed to eliminate the short-term voltage disturbances that occur in the grid-connected mode, the switching between grid-connected mode and the stand-alone mode of a Microgrid. The proposed DVR structure is based on a conventional cascaded H-bridge multilevel inverter (MLI) topology; a novel composite control strategy is presented, which could ensure the compensation ability of voltage sag by the DVR. Moreover, the compensation to specified order of harmonic is added to implement effects that zero-steady error compensation to harmonic voltage in specified order of the presented control strategy; utilizing wind turbines-batteries units as DC energy storage components in the Microgrid, the operation cost of the DVR is reduced. When the Microgrid operates under stand-alone mode, the DVR can operate on microsource mode, which could ease the power supply from the main grid (distribution network) and consequently be favorable for energy saving and emission reduction. Simulation results validate the robustness and effective of the proposed DVR system.

High-Performance Control of Three-Phase Four-Wire DVR Systems using Feedback Linearization

  • Jeong, Seon-Yeong;Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.351-361
    • /
    • 2016
  • Power quality is a critical issue in distribution systems, where a dynamic voltage restorer (DVR) is commonly used to mitigate the voltage disturbances for loads. This paper deals with a nonlinear control for the three-phase four-wire (3P-4W) DVR under a grid voltage unbalance and nonlinear loads in the distribution system, where a novel control scheme based on the feedback linearization technique is proposed. Through feedback linearization, a nonlinear model of a DVR with a PWM voltage-source inverter (VSI) and LC filters is linearized. Then, the controller design of the linearized model is performed by applying the linear control theory, where the load voltages are kept constant by controlling the d-q-0 axis components of the DVR output voltages. To keep the load voltage unchanged, an in-phase compensation strategy is employed, where the load voltages are recovered to be the same as the previous voltage without a change in the magnitude. With this strategy, the performance of the DVR becomes faster and more stable even under unbalanced source voltages and nonlinear loads. The validity of the proposed control strategy has been verified by simulation and experimental results.

Full-HD급 PC기반 DVR System 구현을 위한 FPGA 활용에 관한 연구 (A Study on FPGA utilization For PC-based Full-HD DVR System Implementation)

  • 김기화
    • 한국산학기술학회논문지
    • /
    • 제15권4호
    • /
    • pp.2363-2369
    • /
    • 2014
  • DVR 시스템은 다수의 카메라를 지원하고 채널당 30프레임의 영상을 실시간으로 받을 수 있어야 한다. 따라서 Full-HD급 Multiplexer와 별도의 하드웨어 압축 Codec을 사용하는데, 본 논문에서는 이들을 사용하지 않고 FPGA와 CPU가 가지고 있는 GPU를 이용하여 4채널 Full-HD급 PC기반 DVR의 설계 및 구현 방법에 대하여 기술한다. Multiplexer와 H/W Codec을 사용하지 않는 기존의 방법으로는 실시간으로 채널당 20프레임 정도의 영상을 획득하는 단점을 가지고 있다. FPGA를 이용하여 다채널의 영상을 실시간으로 획득하는 시스템을 설계하였으며, 소프트웨어로는 Intel Media SDK를 이용하여 영상 압축을 구현하였다. 구현된 제품의 성능 평가 결과, 제시한 요구 성능을 모두 만족하였고, 하드웨어 압축 코덱디바이스를 제거함으로써 시스템의 실용성을 확인 하였다.

온도ㆍ일장 2차원 Non-Parametric 모형에 의한 건답직파재배 벼의 출아기 예측 (Application of Non-Parametric Model to Prediction of Heading Date in Direct-Seeded Rice)

  • 이변우
    • 한국작물학회지
    • /
    • 제36권2호
    • /
    • pp.97-106
    • /
    • 1991
  • 온도와 일장을 예측변수로 하는 2차원 non-par-ametric model을 개발하여, 건답직파재배에서 파종기 이동 및 단일처리 (26개품종, 4월 10일부터 2주 간격으로 8회 파종, 해지기 직전 1시간 차광)를 하여 얻은 자료로부터 출아에서 출수까지의 일평균발육속도(DVR)를 추정하였다. 또한 여기서 추정한 DVR을 이용 독립자료에 대하여 모델을 검증하였다. 1. 발육 예측정도는 온도와 일장에 대한 smoothing parameter λ$_{T}$ 와 λ$_{L}$에 따라서 단조적으로 변하였으며 예측정도를 가장 높게하는 λ$_{T}$ 와 λ$_{L}$이 존재하였다. 2. 최적 λ$_{T}$와 λ$_{L}$은 품종에 따라서 달랐으며 5~100,000의 범위내에 있었다 3. 최적 λ$_{T}$와 λ$_{L}$에서 구한 DVR을 이용하여 발육을 예측하는 경우 C.V는 품종에 따라 0.5-2.6% 였으며 기존의 함수모델들 보다 예측 정도가 높았다 4. DVR을 계산하는데 이용되지 않은 독립자료를 이용하여 11개 품종을 대상으로 출수기를 예측한 결과 예측오차는 0-3일로 추정 정도가 높았다.

  • PDF

영상저장장치(DVR)디자인 개발을 위한 제품 분석 (Product development for Digital Video Recorder Design Analysis)

  • 최종운
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.135-145
    • /
    • 2012
  • 네트워크 카메라 영상을 저장하는 DVR(Digital Video Recorder) 디자인 개발 연구 사례이다. 지금까지의 영상저장장치(DVR)는 아날로그 영상을 디지털 방식으로 변환 압축하여 저장하는 방식이었지만 앞으로는 네트워크 카메라를 통해 디지털 영상을 그대로 저장하는 방식으로 발전해 가고 있다. 또한 영상압축방식도 기존방식에서 고화질영상압축효율, 데이터크기 최소화, 네트워크와의 호환성, 제품의 처리속도 등을 고려한 제품들이 개발추세에 있다. 이에 따라 2012년에는 전 세계 네트워크 카메라와 영상처리장치의 판매 비율이 기존의 아날로그 방식의 제품군들을 크게 추월할 것으로 예상되며 이러한 기술 환경과 시장의 요구 변화에 있어서 기능구현, 신뢰성확보 등과 같이 품질 중심의 제품개발과 DVR의 개발 컨셉은 대형화되고 선명한 화질과 압축 기술의 향상으로 인하여 현재와는 다른 새로운 디자인을 요구하고 있으며, 제조사들은 사용자 중심의 제품디자인에 새로운 컨셉 방향으로 연구 개발하는 추세에 있다.

동적전압보상기를 위한 정합 변압기의 돌입전류 제어 (Inrush Current Control of Matching Transformer for Dynamic Voltage Restorer)

  • 서일동;전희종;손진근
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.340-348
    • /
    • 2006
  • 본 논문에서는 동적전압보상기 (DVR)를 구성하기 위한 정합 변압기의 돌입전류 제어기법을 제안하였다. DVR 시스템은 배전계통에서 발생하는 순시적 전압강하를 보상하기 위한 직렬전압 주입장치로서, 임의의 전압을 생성하는 PWM 인버터와 전압 평활용 LC 수동필터 및 절연을 위한 정합 변압기 등으로 구성된다. 그러나 정합 변압기의 사용은 변압기내에서 자속 포화현상에 의하여 정격의 수배에 달하는 돌입전류가 발생하여 시스템의 절연파괴를 초래하고 이 때문에 변압기의 정격용량을 2 배 정도로 초과하여 사용하게 한다. 따라서 본 연구에서는 정합 변압기의 자속 포화현상에 따른 돌입전류의 크기를 분석할 수 있는 새로운 모델링 분석기법 및 돌입전류의 크기를 제한하는 자화전류 제어기법을 제안하였다. 모의실험 및 실험을 통하여 제안된 DVR 제어기법의 타당성을 입증하였다.

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.62-68
    • /
    • 2013
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.