• Title/Summary/Keyword: DRR

Search Result 75, Processing Time 0.022 seconds

Fair Bandwidth Allocation in Core-Stateless Networks (Core-Stateless망에서의 공정한 대역폭 할당 방식)

  • Kim Mun-Kyung;Park Seung-Seob
    • The KIPS Transactions:PartC
    • /
    • v.12C no.5 s.101
    • /
    • pp.695-700
    • /
    • 2005
  • To provide the fair rate and achieve the fair bandwidth allocation, many per-flow scheduling algorithms have been proposed such as fair queueing algorithm for congestion control. But these algorithms need to maintain the state, manage buffer and schedule packets on a per-flow basis; the complexity of these functions may prevent them from being cost-effectively implemented. In this paper, therefore, to acquire cost-effectively for implementation, we propose a CS-FNE(Core Stateless FNE) algorithm that is based on FM(Flow Number Estimation), and evaluated CS-FNE scheme together with CSFQ(Core Stateless Fair Queueing), FRED(Fair Random Early Detection), RED(Random Early Detection), and DRR(Dynamic Round Robin) in several different configurations and traffic sources. Through the simulation results, we showed that CS-FNE algorithm can allocate fair bandwidth approximately than other algorithms, and CS-FNE is simpler than many per-flow basis queueing mechanisms and it can be easily implemented.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF

Establishment of Evaluation System for Disaster Resilience Focusing on the Local Road under Complex Disaster (복합재해 발생 예상 시 지방도로 중심의 재난 레질리언스 평가체계 구축)

  • Kim, Young-Hwan;Jun, Kye-Won
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.37-46
    • /
    • 2020
  • Although the importance of resilience is emerging around the world, the single definition of resilience related to natural disasters is not clear. The reason for this is that there is no specific definition of how the definition of resilience relates to similar terms such as vulnerability, recovery, adaptability, and sustainability. In addition, it is because each country and region have different geographic and geological characteristics, and each measurement index is different, just as typhoons, droughts, and earthquakes have different types of disasters. Therefore, in this study, the definition of resilience is reflected in the spatial characteristics of this study as the ability to recover from'complex disasters (concentrated heavy rain, landslides, earth and stone flows) occurring on local roads or on local roads adjacent to people or facilities. Defined. And it was divided into DRR: Disaster Resilience focusing on the Road. In addition, domestic and foreign literature surveys were conducted to derive road-centered disaster resilience factors, and a hierarchical structure was established and AHP survey was conducted to establish a DRR evaluation system. As a result of the analysis of the AHP survey, the weight of direct road disaster influencing factors (drainage facilities, protection facilities, etc.) located inside local roads was 0.742, and the weight of indirect road disaster influencing factors (population, property, etc.) located near local roads. Was found to be 0.258, indicating that the direct impact factor of road disaster was relatively higher than that of the indirect impact factor.

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Development of Demand Response Operation System for Load Aggregators (부하관리사업자용 수요반응 운영 시스템 개발)

  • Kim, Ji-Hui;Moon, Guk-Hyun;Joo, Sung-Kwan;Oh, Jae-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2221-2224
    • /
    • 2011
  • During an emergency due to a shortage of power, a load aggregator (LA) can use the demand response operation system to deploy demand response resources (DRRs) through various demand response (DR) programs. This paper introduces the demand response operation system for a load aggregator to manage various demand response resources in a smart grid environment.

The relationships between the arrangement of teeth, root resorption, and dental maturity in bovine mandibular incisors

  • An, Jin-kyu;Matsumoto, Yoshiro;Ono, Takashi
    • The korean journal of orthodontics
    • /
    • v.47 no.6
    • /
    • pp.365-374
    • /
    • 2017
  • Objective: The objective of this study is to investigate the eruption pattern and root resorption of the bovine anterior dentition in relation to growth-related parameters based on dental maturity. Methods: A cross-sectional study was conducted on 110 bovine anterior mandibles by using standard radiography, cone-beam computed tomography (CBCT), and actual measurements. We determined the relationships between the stages of dental maturity by using a modification of Demirjian's method and various growth-related parameters, such as the activity of the root-resorbing tissue and mobility of the deciduous teeth. The correlation of growth-related parameters with interdental spacing and distal unusual root resorption (DRR) of the deciduous fourth incisor was assessed. The cause of mesial unusual root resorption (MRR) of the deciduous fourth incisor was determined on the basis of the arrangement of the permanent third incisor. Results: An independent t-test and chi-square test indicated significant differences in growth-related parameters associated with dental arch length discrepancy and factors related to the shedding of deciduous teeth between the low and high dental maturity groups. The samples with interdental spacing and DRR showed a larger sum of mesiodistal permanent crown widths and higher dental maturity than did the respective controls. Samples with MRR tended to show a lingually rotated distal tip of the adjacent tooth crown. Conclusions: Dental maturity has relevance to the interdental spaces and unusual root resorption of mixed dentition. The position of the adjacent tooth crown on CBCT may be correlated with the occurrence of unusual root resorption of the incisor.

Scheduling Algorithm for Military Satellite Networks using Dynamic WDRR(Weighted Deficit Round Robin) (군사용 위성통신망을 위한 동적 WDRR기반의 스케줄링 알고리즘)

  • Lee, Gi-Yeop;Song, Kyoung-Sub;Kim, Dong-Seong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.196-204
    • /
    • 2013
  • In this paper, a scheduling algorithm is proposed for military satellite networks to improve QoS(Quality of Service) based on WDRR(Weighted Deficit Round Robin) method. When the packet size that has been queued to be larger, the proposed scheme DWDRR(Dynamic WDRR) method give appropriate additional quantum using EWMA(Exponentially Weighted Moving Average). To demonstrate an usefulness of proposed algorithm using OPNET modeler that built the simulation environment, reliability and real-time availability of the proposed algorithm is analyzed. The simulation results show an availability of proposed scheme in terms of reduce queuing delay and packet drop rate compared and analyzed the existing algorithms WRR(Weighted Round Robin), DRR(Deficit Round Robin) and WDRR with DWDRR.

Typological System of Nature-based Solutions and Its Similar Concepts on Water Management (물관리를 위한 자연기반해법과 유사개념들의 유형분류 및 체계)

  • Woo, Hyoseop;Han, Seung-wan
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.1
    • /
    • pp.15-25
    • /
    • 2020
  • We've compared and conceptually evaluated the newly emerging concept of nature-based solutions (NbS's), in the aspect of water management, and existing similar solutions of different naming, all of which are based on ecosystem functions. In this study, it is found that NbS's seem significant and meaningful both educationally and understandably in the aspect that it can comprehensively cover and include the existing methodologies and solutions using the functions of natural ecosystem to socio-environmental challenges. It, however, seems not quite different from the broad-meaning of green infra, including Eco-DRR, in terms of the approaching methodologies in water management. The conceptual and spatial hierarchy of each practice in water management considered in this study can be expressed in the narrowing order of NbS-(EE)-BGI-(CRT)-GI-LID. Last, the term LID, which is the best management practice for storm water management in the development project, can be replaced with the term GI for clarification and less confusion both in academia and practice.