• Title/Summary/Keyword: DR system

Search Result 528, Processing Time 0.027 seconds

A 15 nm Ultra-thin Body SOI CMOS Device with Double Raised Source/Drain for 90 nm Analog Applications

  • Park, Chang-Hyun;Oh, Myung-Hwan;Kang, Hee-Sung;Kang, Ho-Kyu
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.575-582
    • /
    • 2004
  • Fully-depleted silicon-on-insulator (FD-SOI) devices with a 15 nm SOI layer thickness and 60 nm gate lengths for analog applications have been investigated. The Si selective epitaxial growth (SEG) process was well optimized. Both the single- raised (SR) and double-raised (DR) source/drain (S/D) processes have been studied to reduce parasitic series resistance and improve device performance. For the DR S/D process, the saturation currents of both NMOS and PMOS are improved by 8 and 18%, respectively, compared with the SR S/D process. The self-heating effect is evaluated for both body contact and body floating SOI devices. The body contact transistor shows a reduced self-heating ratio, compared with the body floating transistor. The static noise margin of an SOI device with a $1.1\;{\mu}m^2$ 6T-SRAM cell is 190 mV, and the ring oscillator speed is improved by 25 % compared with bulk devices. The DR S/D process shows a higher open loop voltage gain than the SR S/D process. A 15 nm ultra-thin body (UTB) SOI device with a DR S/D process shows the same level of noise characteristics at both the body contact and body floating transistors. Also, we observed that noise characteristics of a 15 nm UTB SOI device are comparable to those of bulk Si devices.

  • PDF

The development of product inspection X-ray DR image processing system using intensifying screen (형광지를 이용한 물품검사 X-선 DR 영상처리 시스템 개발)

  • Park, Mun-kyu;Moon, Ha-jung;Lee, Dong-hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1737-1742
    • /
    • 2015
  • In the industrial field for product inspection needs not only on the surface of the product but also the internal components defect inspection. Generally, optical inspection is mainly used for item inspection from production process. However, this is only to check defect of surface it is difficult to perform inspection of goods internal. To overcome these limitations, Instead of optical device by using the portable X- ray DR image acquisition device system developed to obtain an image in real time at the same time and determine product defects. After obtaining the X- ray image, the inspection product within error range is passed after machine image processing. Also, the results and numbers are stored by users.

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

Cytotoxicity Effects of Mouse IgG Produced against Three Nanoliposomal Human DR5 Receptor Epitopes on Breast Cancer Cells

  • Amirijavid, Shaghayegh;Entezari, Maliheh;Movafagh, Abolfazl;Hashemi, Mehrdad;Mosavi-Jarahi, Alireza;Dehghani, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.257-261
    • /
    • 2016
  • Cancer causes cells to avoid death while being the second cause of death in the world itself. Damaged cells in the absence of apoptosis will increasingly amplify their inefficient genome. Of the two main apoptosis inducing pathways in cells, the first has p53 protein as the main initiating factor in the cascade. According to research results this protein s mutated in 50% of cancers and sointerest has cooncentrated on the second pathway that features death receptors. Among these receptors TRAIL1/DR5 is especially expressed in cancer cells. So targeting such receptors can initiate the apoptotic cascade in cells. Interestingly by substitution of activating ligands with antibodies as agonists, we could efficiently turn on the apoptosis pathway. First of all, three small peptides from the DR5 protein extracellular domain were synthesized and injected with two different kind of adjuvants (Fround and liposomal encapsulation) separately into mice at 15 day intervals. As a result, liposomal peptides induced the immune system more efficient than Frounds adjuvant and at the end point the antibodies which were obtained from liposomal peptide injection induced much more effective death. Liposomal formol could be used as an adjuvant in immunization utilizing small peptides. They carry, protect and deliver peptides very efficiently. In addition, small peptides of a certain size from the extracellular domain of DR5 proteins not only can induce immune system but also produce antibodies playing a remarkable anti-cancer roles against breast cancer cells (MCF-7).

Database design and production in ETLARS system (ETLARS 시스템에서의 데이터베이스 설계 및 생성에 관한 연구)

  • 김상도;박계숙;김희섭;홍기채;우동진;기민호
    • Journal of the Korean Society for information Management
    • /
    • v.11 no.2
    • /
    • pp.165-184
    • /
    • 1994
  • DB production process includes a series of data analysis, DB design, source data input, data conversion and load, and DB operation and maintenance. Software development and operation technique for data input and DR production is similar to each other, even though each computer environment or the function of information retrieval system is a little different. The purpose of this paper is to introduce software for data input and DR production in ETLARS system, which is providing services to 6.000 users ( a s of Oct. 10, 1994) by Electronics and Telecommunications Research Institute, and to open know-how information in the production and operation of Hanguel DR.

  • PDF

Smart meter data transmission device and power IT system using LTE and IoT technologies (LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템)

  • Kang, Ki-Beom;Kim, Hong-Su;Jwa, Jeong-Woo;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.117-124
    • /
    • 2017
  • A Smart Grid is a system that can efficiently use energy by exchanging real-time information in both directions between a consumer and a power supplier using ICT technology on an existing power network. DR(Demand response) is an arrangement in which electricity users can sell the electricity they save to the electricity market when the price of electricity is high or the power system is crisis. In this study, we developed a power meter data transmission device and power IT system that measure the demand information in real-time using a smart meter and transmit it to a cloud server. The power meter data transmission device developed in this study uses alight sensor connected to a Raspberry Pi 3 to measure the number of blinking lamps on the KEPCO meter per unit of power, in order to provide reliable data without any measurement errors with respect to the KEPCO power data. The power measurement data transmission device uses the standard communication protocol, OpenADR 2.0b. The measured data is transmitted to the power IT system, which consists of the VEN, VTN, and calculation program, via the LTE WiFi communication network and stored in its MySQL DB. The developed power measurement data transmission device issues a power supply instruction and performs a peak reduction DR when a power system crisis occurs. The developed power meter data transmission device has the advantage of allowing the user to adjust it every 1 minute, where as the existing smart metering time is fixed at once every 15 minutes.

Long-Term Exposure of Sildenafil Citrate on Sperm Parameters in Rat

  • Suresh, Sekar;Prithiviraj, Elumali;Venkatalakshmi, Nagella;Ganesh, Mohanraj Karthik;Ganesh, Lakshmanan;Lee, Hyun-Jeong;Prakash, Seppan
    • Reproductive and Developmental Biology
    • /
    • v.35 no.4
    • /
    • pp.435-439
    • /
    • 2011
  • Sildenafil citrate (SIL) a phosphodiesterase 5 inhibitor (PDE5I) has been used for long time as a first line oral drug for erectile dysfunction. Though it has beneficial effects on erectile organ it also has some adverse effects in other cells and/or tissues related to reproductive system when exposed to longer duration. The objective of the present study is to evaluate the long term effect of SIL on sperm parameters in Wistar albino rat. The animals are divided into two groups, for group I - rats were treated with saline (vehicle alone) and group - II oral administration of 5 mg/kg b.w. of SIL was administrated orally once in a day for 120 days. At the end of the trial period animals were sacrificed and epididymal sperm were subjected to various analysis. Results showed significant reduction in sperm count, motility, viability and morphologically intact sperm in long term PDE5I exposed animals when compared to control. Acrosomal status and fertility test also showed significant reduction in long term PDE5I exposed animals. The present study clearly indicated that long term SIL has shown to induce alteration in sperm quality and quantity, leading to decline in fertility rate. Indicate that SIL impinge on spermatogenesis as well as epididymal function. Understanding the molecular down-stream events involved in long-term exposure to PDE5 inhibitor can be valuable to supervise on related infertility issues and to suggest corrective measures.

A novel approach to the form-finding of membrane structures using dynamic relaxation method

  • Labbafi, S. Fatemeh;Sarafrazi, S. Reza;Gholami, Hossein;Kang, Thomas H.K.
    • Advances in Computational Design
    • /
    • v.2 no.3
    • /
    • pp.123-141
    • /
    • 2017
  • Solving a system of linear or non-linear equations is required to analyze any kind of structures. There are many ways to solve a system of equations, and they can be classified as implicit and explicit techniques. The explicit methods eliminate round-off errors and use less memory. The dynamic relaxation method (DR) is one of the powerful and simple explicit processes. The important point is that the DR does not require to store the global stiffness matrix, for which it just uses the residual loads vector. In this paper, a new approach to the DR method is expressed. In this approach, the damping, mass and time steps are similar to those of the traditional method of dynamic relaxation. The difference of this proposed method is focused on the method of calculating the damping. The proposed method is expressed such that the time step is constant, damping is equal to zero except in steps with maximum energy and the concentrated damping can be applied to minimize the energy of system in this step. In this condition, the calculation of damping in all steps is not required. Then the volume of computation is reduced. The DR method for form-finding of membrane structures is employed in this paper. The form-finding of the three plans related to the membrane structures with different loading is considered to investigate the efficiency of the proposed method. The numerical results show that the convergence rate based on the proposed method increases in all cases than other methods.

DEEP-South: Automated Scheduler and Data Pipeline

  • Yim, Hong-Suh;Kim, Myung-Jin;Roh, Dong-Goo;Park, Jintae;Moon, Hong-Kyu;Choi, Young-Jun;Bae, Young-Ho;Lee, Hee-Jae;Oh, Young-Seok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.54.3-55
    • /
    • 2016
  • DEEP-South Scheduling and Data reduction System (DS SDS) consists of two separate software subsystems: Headquarters (HQ) at Korea Astronomy and Space Science Institute (KASI), and SDS Data Reduction (DR) at Korea Institute of Science and Technology Information (KISTI). HQ runs the DS Scheduling System (DSS), DS database (DB), and Control and Monitoring (C&M) designed to monitor and manage overall SDS actions. DR hosts the Moving Object Detection Program (MODP), Asteroid Spin Analysis Package (ASAP) and Data Reduction Control & Monitor (DRCM). MODP and ASAP conduct data analysis while DRCM checks if they are working properly. The functions of SDS is three-fold: (1) DSS plans schedules for three KMTNet stations, (2) DR performs data analysis, and (3) C&M checks whether DSS and DR function properly. DSS prepares a list of targets, aids users in deciding observation priority, calculates exposure time, schedules nightly runs, and archives data using Database Management System (DBMS). MODP is designed to discover moving objects on CCD images, while ASAP performs photometry and reconstructs their lightcurves. Based on ASAP lightcurve analysis and/or MODP astrometry, DSS schedules follow-up runs to be conducted with a part of, or three KMTNet telescopes.

  • PDF