• Title/Summary/Keyword: DFO

Search Result 27, Processing Time 0.018 seconds

Comparative Studies of Protein Modification Mediated by Fenton-like Reactions of Iron, Hematin, and Hemoglobin: Generation of Different Reactive Oxidizing Species

  • Kim, Young-Myeong;Kim, Sung-Soo;Kang, Gu;Yoo, Yeong-Min;Kim, Ki-Mo;Lee, Mi-Eun;Han, Jeong-A;Hong, Sun-Joo
    • BMB Reports
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 1998
  • TThe reactive oxygen species oxidatively modify the biological macromolecules, including proteins, lipids, and nucleic acids. Iron- and heme-mediated Fenton-like reactions produce different pro-oxidants. However, these reactive products have not been clearly characterized. We examined the nature of the oxidizing species from the different iron sources by measuring oxidative protein modification and spectroscopic study. Hemoglobin (Hb) and methemoglobin (metHb) were oxidatively modified in $O{\array-\\\dot{2}}$ and $H_{2}O_{2}$ generating systems. Globin and bovine serum albumin (BSA) were also modified by iron, iron-EDTA, hematin, and Hb in an $O{\array-\\\dot{2}}$ generating system. In a $H_{2}O_{2}$ generating system, the iron- and iron-EDTA-mediated protein modifications were markedly reduced while the Hb-and hematin-mediated modifications were slightly increased. In the $O{\array-\\\dot{2}}$ generating system, the iron- and iron-EDTA-mediated protein modifications were strongly inhibited by superoxide dismutase (SOD) or catalase, but heme- and Hb-mediated protein modifications were inhibited only by catalase and slightly increased by SOD. Mannitol, 5,5-dimethyl-l-pyrroline-N-oxide (DMPO), deoxyribose, and thiourea inhibited the iron-EDTA-mediated protein modification. Mannitol and DMPO, however, did not exhibit significant inhibition in the hematin-mediated modification. Desferrioxamine (DFO) inhibited protein modification mediated by iron, but cyanide and azide did not, while the hematin-mediated protein modification was inhibited by cyanide and azide, but not significantly by DFO. The protein-modified products by iron and heme were different. ESR and UV-visible spectroscopy detected the DMPO spin adduct of the hydroxyl radical and ferryl ion generated from iron-EDTA and metHb, respectively. These results led us to conclude that the main oxidizing species are hydroxyl radical in the iron-EDTA type and the ferry I ion in the hematin type, the latter being more effective for protein modification.

  • PDF

Simple measurement the chelator number of antibody conjugates by MALDI-TOF MS

  • Shin, Eunbi;Lee, Ji Woong;Lee, Kyo Chul;Shim, Jae Hoon;Cha, Sangwon;Kim, Jung Young
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.54-58
    • /
    • 2017
  • Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS) is one of the powerful methods that enable analysis of small molecules as well as large molecules up to about 500,000 Da without severe fragmentation. MALDI-TOF MS, thus, has been a very useful an analytical tool for the confirmation of synthetic molecules, probing PTMs, and identifying structures of a given protein. In recent nuclear medicine, MALDI-TOF MS liner ion mode helps researcher calculate the average number of chelator(or linkage) per an antibody conjugate, such as DOTA-(or DFO-) trastuzumab for labeling a medical radioisotope. This simple technique can be utilized to improve the labeling method and control the quality at the development of antibody-based radiopharmaceuticals, which is very effected to diagnosis and therapy for in vivo tumor cells, with radioisotopes like $^{89}Zr$, $^{64}Cu$, and 177Lu. To minimize the error, MALDI-TOF MS measurement is repeatedly performed for each sample in this study, and external calibration is carried out after data collection.

A Study on Application and Comparison of Effectiveness of Ninhydrin Reagents on Special Paper Surfaces (특수 종이 표면에서 ninhydrin 계열 시약의 적용 및 효과성 비교에 관한 연구)

  • Kim, Chung;Cho, Hyeong-Woo;Koh, Hyun-Seo;Yu, Je-Seol
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.9
    • /
    • pp.247-253
    • /
    • 2016
  • Some previous studies had proven that ninhydrin or its analogues are not effective in developing fingermarks on some types of paper. This study has evaluated the efficiency of four reagents for detecting latent fingermarks on six unusual paper surfaces. Among the six types of paper surfaces, none of the reagents worked on the newspaper. The 1,2-IND/Zn developed fingermarks on most of the surfaces tested.

Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.

Radiolabeling of nanoparticle for enhanced molecular imaging

  • Kim, Ho Young;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.103-112
    • /
    • 2017
  • The combination of nanoparticle with radioisotope could give the in vivo information with high sensitivity and specificity. However, radioisotope labeling of nanoparticle is very difficult and radioisotopes have different physicochemical properties, so the radioisotope selection of nanoparticle should be carefully considered. $^{18}F$ was first option to be considered for labeling of nanoparticle. For the labeling of $^{18}F$ with nanoparticle, Prosthetic group is widely used. Iodine, another radioactive halogen, is often used. Since radioiodine isotopes are various, they can be used for different imaging technique or therapy in the same labeling procedures. $^{99m}Tc$ can easily be obtained as pertechnatate ($^{99m}{TcO_4}^-$) by commercial generator. Ionic $^{68}Ga$ (III) in dilute HCl solution is also obtained by generator system, but $^{68}Ga$ can be substituted for $^{67}Ga$ because of the short half-life (67.8 min). $^{64}Cu$ emits not only positron but also ${\beta}-particle$. Therefore $^{64}Cu$ can be used for imaging and therapy at the same time. These radioactive metals can be labeled with nanoparticle using the bifunctional chelator. $^{89}Zr$ has longer half-life (78.4 h) and is used for the longer imaging time. Unlike different metals, $^{89}Zr$ should use the other chelate such as DFO, 3,4,3-(LI-1,2-HOPO) or DFOB.

Efficient Flooding Mechanisms with Considering Data Transmission Characteristics of the Wireless Sensor Network (무선 센서 네트워크의 데이터 전송 특성을 고려한 효율적인 플러딩 기법)

  • Ahn, Sang-Hyun;Lim, Yu-Jin;Kim, Mahn-Hee
    • The KIPS Transactions:PartC
    • /
    • v.16C no.2
    • /
    • pp.209-216
    • /
    • 2009
  • In the wireless sensor network, flooding is required for the dissemination of queries and event announcements. The simple flooding causes the implosion and the overlap problems, so the simple flooding may result in the reduced network lifetime. Therefore, in this paper, we propose the flooding overlay structure (FOS) so that the overhead caused by flooding can be reduced. We propose two variants of FOS mechanisms, the centralized FOS (CFOS) and the distributed FOS (DFOS). In CFOS, the sink collects the network topology information and selects forwarding nodes based on that information. On the other hand, DFOS allows each sensor node to decide whether to act as a forwarding node or not based on its local information. For the performance evaluation of our proposed mechanisms, we carry out NS-2 based simulations and compare ours with the simple flooding and the gossiping. The simulation results indicate that the proposed FOS mechanisms outperform the simple flooding in terms of the network lifetime and the gossiping in terms of the data delivery ratio.

Evaluation of fingerprints enhanced fluorescent using contrast index (Contrast Index를 이용한 형광지문 증강 정도의 수치적 판단)

  • Jeon, Soyoung;Ki, Jinyoung;Kim, Kyuyeon;Kim, Jiyeon;Kim, Chaewon;Yu, Jeseol
    • Analytical Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.195-200
    • /
    • 2018
  • Researchers have used the visual criteria to compare the effectiveness of fingerprint enhancement techniques. However, since the visual criteria is subjective, bias can occur. Therefore, many researchers have tried to make the criteria objective using the contrast index (CI). However, there is a constraint that the CI was only validated on inked fingerprints or color-change fingerprints. In this study, we compared enhancement of fluorescence fingerprints on colored papers using the CI. The CI values differ according to the color of the background, reagent, and light source, even though the same standard fingerprints were used. Through the comparison of values, we could compare the enhancement of fluorescence fingerprints according to these factors. When visual evaluation criteria were used, the same peak score was obtained regardless of the reagent and light source. However, we could get a more detailed score comparison in this study using the CI. Therefore, it is confirmed that for comparison of enhancement of fluorescence fingerprints, the CI can be used as a basis for determining which light source and reagent are appropriate according to the background.