DOI QR코드

DOI QR Code

Simple measurement the chelator number of antibody conjugates by MALDI-TOF MS

  • Shin, Eunbi (Korea Drug Development Platform using radio-isotope) ;
  • Lee, Ji Woong (Department of RI-Convergence Research, Korea Institute of Radiological and Medical Sciences) ;
  • Lee, Kyo Chul (Department of RI-Convergence Research, Korea Institute of Radiological and Medical Sciences) ;
  • Shim, Jae Hoon (Korea Drug Development Platform using radio-isotope) ;
  • Cha, Sangwon (Department of Chemistry, Hankuk University of Foreign Studies) ;
  • Kim, Jung Young (Korea Drug Development Platform using radio-isotope)
  • Received : 2017.09.27
  • Accepted : 2017.12.23
  • Published : 2017.12.30

Abstract

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS) is one of the powerful methods that enable analysis of small molecules as well as large molecules up to about 500,000 Da without severe fragmentation. MALDI-TOF MS, thus, has been a very useful an analytical tool for the confirmation of synthetic molecules, probing PTMs, and identifying structures of a given protein. In recent nuclear medicine, MALDI-TOF MS liner ion mode helps researcher calculate the average number of chelator(or linkage) per an antibody conjugate, such as DOTA-(or DFO-) trastuzumab for labeling a medical radioisotope. This simple technique can be utilized to improve the labeling method and control the quality at the development of antibody-based radiopharmaceuticals, which is very effected to diagnosis and therapy for in vivo tumor cells, with radioisotopes like $^{89}Zr$, $^{64}Cu$, and 177Lu. To minimize the error, MALDI-TOF MS measurement is repeatedly performed for each sample in this study, and external calibration is carried out after data collection.

Keywords

References

  1. Michael K, Franz H. Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Anal Chem. 1988;60:2299-2301 https://doi.org/10.1021/ac00171a028
  2. Yu W, Vath JE, Huberty MC, Martin SA. Identification of the facile gas-phase cleavage of the Asp-Pro and Asp-Xxx peptide bonds in matrix-assisted laser desorption time-offlight mass spectrometry. Anal Chem. 1993;65:3015-3023 https://doi.org/10.1021/ac00069a014
  3. Huberty M, Vath J, Yu W, Martin S. Site-specific carbohydrate identification in recombinant proteins using MALDI-TOF MS. Anal Chem. 1993;65:2791-2800 https://doi.org/10.1021/ac00068a015
  4. Ouyang Z, Takáts Z, Blake TA, Gologan B, Guymon AJ, Wiseman JM, Oliver JC, Davisson VJ, Cooks RG. Preparing protein microarrays by soft-landing of massselected ions. Science 2003;301:1351-1354 https://doi.org/10.1126/science.1088776
  5. Caprioli RM, Farmer TB, Gile J. Molecular imaging of biological samples: localization of peptides and proteins using MALDI-TOF MS. Anal Chem. 1997;69:4751-4760 https://doi.org/10.1021/ac970888i
  6. Balluff B, Schöne C, Höfler H, Walch A. MALDI imaging mass spectrometry for direct tissue analysis: technological advancements and recent applications. Histochem Cell Biol. 2011;136:227-244 https://doi.org/10.1007/s00418-011-0843-x
  7. Wang S, Chen X, Luan H, Gao D, Lin S, Cai Z, Liu J, Liu H, Jiang Y . Matrix-assisted laser desorption/ ionization mass spectrometry imaging of cell cultures for the lipidomic analysis of potential lipid markers in human breast cancer invasion. Rapid Commun. Mass Spectrom. 2016;30:533-542 https://doi.org/10.1002/rcm.7466
  8. Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM. Electrospray ionization for mass spectrometry of large biomolecules, Science 1989;246:64-71 https://doi.org/10.1126/science.2675315
  9. Vertes A, Levine RD. Levine. Sublimation Versus Fragmentation in Matrix-assisted laser desorption. CHEM. Phys. Lett. 1990;171:284-290 https://doi.org/10.1016/0009-2614(90)85365-J
  10. Lubman DM, Bell WE, Kronick MN. Linear mass reflectron with a laser photoionization source for time-offlight mass spectrometry. Anal Chem. 1983;55:1437-1440 https://doi.org/10.1021/ac00259a062
  11. Cornish TJ, Cotter RJ. A curved-field reflectron for improved energy focusing of product ions in time-offlight mass spectrometry. Rapid Commun Mass Spectrom. 1993;7:1037-1040 https://doi.org/10.1002/rcm.1290071114
  12. Pandya DN, Bhatt N, Dale AV, Kim JY, Lee H, Ha YS, Lee JE, An GI, Yoo J. New bifunctional chelator for 64Cuimmuno- positron emission tomography. Bioconjugate Chemistry. 2013;24:1356-1366 https://doi.org/10.1021/bc400192a