• Title/Summary/Keyword: DC-link

Search Result 1,020, Processing Time 0.022 seconds

The Elimination Method of Ripple Voltage for a Single Grid-Connected PV System (단상 계통연계형 태양광 발전시스템의 맥동전압제거 기법)

  • Lee, Jae-Geun;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.406-407
    • /
    • 2011
  • The dc link voltage in a single-phase PV system has necessarily twice component of fundamental wave. It makes high THD in the grid current, and according to the problem, power quality is lower. This paper proposes the new method for removing ripple voltage. The performance was verified through computer simulation using MATLAB.

  • PDF

Bidirectional Dual Active Half-Bridge Converter Integrated High Power Factor Correction

  • Ngo, AnhTuan;Nam, Kwanghee
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.444-446
    • /
    • 2011
  • A bidirectional dual active converter with the power factor control capability is proposed as a battery charger. The source side half-bridge acts as a PWM converter that maintains the unity power factor. The battery side half-bridge converter acts as a dual active bridge (DAB) together shares the same DC link voltage with PWM converter. The imbalance voltage phenomenon is eliminated by employing asymmetric duty cycle technique. Simulation results are included to verify theoretical analysis.

  • PDF

Active Power Filter with low DC link current ripple (낮은 직류단 전류 리플을 갖는 능동전력필터)

  • Hong, Seung-Pyo;Jung, Young-Gook;Oh, Seung-Yeol;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.23-24
    • /
    • 2012
  • 본 연구에서는 스너버로 동작하는 커패시터 C를 갖는 3상 능동전력필터의 직류측에 인덕터 L을 추가하여 직류단 전류의 리플을 감소시키는 방법을 제안하였다. 능동전력필터는 종전의 스너버 만을 이용하여 능동필터 기능을 수행하는 회로에 L을 추가하여 직류단 전류의 리플을 절반 정도 감소시켜 능동전력 필터의 소자에 스트레스가 줄어드는 것을 실험을 통하여 확인할 수 있었다.

  • PDF

Nonlinear Control of Three-phase Split-Capacitor Inverters under Unbalanced and Nonlinear Load Conditions

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.52-53
    • /
    • 2012
  • This paper presents a new control scheme for a three-phase split DC-link capacitor inverter as an AC power supplies. The proposed control method can maintain the balanced sinusoidal output voltage under unbalanced and nonlinear load conditions. The validity of the control method has been verified by simulation results.

  • PDF

Sensorless Control of PWM Converter Using Extended Kalman Filter (확장 칼만 필터를 이용한 PWM 컨버터 센서리스 제어기법)

  • 허승민;강구배;남광희
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.671-674
    • /
    • 1999
  • In the PWM converter, PLL(Phase Locked Loop) is usually used as a tool which senses the angle of input voltage. This is sensitive to nois and needs additional hardware. In this work, we propose a sensorless control scheme of PWM converter using EKF(Extended Kalman Filter). EKF estimates a phase angle of input voltage from nonlinear state equation using measured phase currents. We control power factor and DC-link voltage utilizing the estimated phase angle. We demonstrate the effectiveness of the proposed estimation algorithm through simulations.

  • PDF

A Study on Parallel Operation of PWM Converter for Auxiliary bloc High Speed Train (고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구)

  • 송상훈;성재원;김연충;원충연;최종묵;기상우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.358-361
    • /
    • 1999
  • In auxiliary block of high speed train power factor correction and harmonics reduction is very important issue for efficient energy transport. The GTO-equipped PWM converter is used for traction untill resently. But the rising power capability of IGBTs resently allows to build IGBT-equipped PWM converter with a considerably increased switching frequency. This paper presents switching pattern, control method, operation mode and tuned filter to reduce dc link voltage ripple for paralleled converter.

  • PDF

Single Sensor Current Control for Three-Phase Voltage-Source PWM Converters Using a Predictive State Observer (예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어)

  • 이우철;현동석;이택기
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.489-492
    • /
    • 1999
  • This paper proposes a control method for three-phase voltage-source PWM converters using only a single current sensor in the DC link. A predictive current controller for the voltage-source PWM converter is used so that all phase currents can be reconstructed in a switching period although one or two of active vectors are applied only for a short time. Compensation of the 2 step delays is also included. In this paper single sensor current control using predictive state observer will be discussed, and investigated experimentally.

  • PDF

A Single Switched Series Element of Series-Parallel Compensated UPS (직병렬 보상형 무정전 전원장치의 단일 스위치 직렬 요소)

  • 이인우;박진형;전성즙
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.106-109
    • /
    • 1999
  • A single-switched series element for series-parallel compensated UPS is proposed. The proposed series element can handle only unidirectional power and the input voltage must be higher than the output voltage. But it is very useful when DC-link voltage is low and isolation transformer is need for output stage since only one active switch is used.

  • PDF

Life Estimation of Electrolytic Capacitors in Inverters (인버터용 전해커페시터의 수명 추정)

  • Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.243-245
    • /
    • 2000
  • In general, aluminum electrolytic capacitors are used in the DC link of PWM inverters fur ac motor drives. The capacitor usually has the shortest lifetime in the system and then determines the lifetime of the inverter system. In this paper, a method of capacitor lifetime estimation is proposed by using an ESR(equivalent series resistance) model and a heat transfer model of capacitor, from which internal operating temperature is estimated. Then, the lifetime is predicted by Arrhenius's equation. A practical example is presented.

  • PDF

Control Hierarchy Analysis of Haenam-Cheju HVDC system (해남-제주 HVDC 계통의 제어 계층 구조 분석)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1327-1330
    • /
    • 1999
  • In this paper control hierarchy of Haenam-Cheju HVDC link are analyzed and their functional specifications are summarized related to their level. The control functions for the submarine DC transmission are implemented by software programs on 16-bit parallel processor-based machines which are composed of subunits hierarchically linked each other

  • PDF