• 제목/요약/키워드: DC-link

검색결과 1,020건 처리시간 0.024초

데드 타임 없는 새로운 공간 벡터 전압 변조 인버터에 관한 연구 (A Study on the Novel Space Vector PWM Inverter without Dead time)

  • 서일수;송의호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1169-1171
    • /
    • 2004
  • Voltage source inverters are required dead time to prevent the short current in the dc link. In recent years, the dead time effect has been investigated in many literatures. This paper presents on the novel space vector PWM inverter without dead time. The proposed inverter don't need to sense load current and to calculate for dead time compensation. Transformers are inserted each leg in the proposed inverter. The proposed method is analyzed each mode and then the simulation results verify the proposed method.

  • PDF

3상 소프트 스위칭 인버터의 전력손실에 관한 해석 (Analysis on power loss of three-phase soft switching inverter)

  • 김주용;문상필;김은수;서기영;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.3-5
    • /
    • 2002
  • This paper proposes a new prototype auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually measured conduction loss characteristic of switching device module. Voltage-type soft switching three phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

Fuse Protection of IGBT Modules against Explosions

  • Blaabjerg, Fred;Ion, Florin;Ries, Kareten
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.88-94
    • /
    • 2002
  • The demand for protection of power electronic application has during the last couple of vears increased regarding the high-power IGBT modules. Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if IGBT Fuses do not protect it. By introducing fuses into the circuit this will increase the circuit inductance and slight inductance over-voltage during the turn-off of the diode and the IGBT. It is therefore vital when using fuses that the added inductance is kept at a minimum. This paper discuss three issues regarding the IGBT Fuse protection of adding inductance of existing High-speed and new Typower Fuse protection. First, the problem of adding inductance of exiting High-speed and new Typower Fuse DC-link circuit is treated, second a short discussion of protection of the IGBT module is done, and finally, the impect of the high frwquency loading on the currying capability of the fuses is presented.

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

Bi-Directional Multi-Level Converter for an Energy Storage System

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.499-506
    • /
    • 2014
  • This paper proposes a 3 kW single-phase bi-directional multi-level converter for energy storage applications. The proposed topology is based on the H-bridge structure with four switches connected to the DC-link. A simple phase opposition disposition PWM method that requires only one carrier signal is also suggested. The switching sequence to balance the capacitor voltage is considered. The topology can be extended to a nine-level converter or a three-phase system. The operating principle of the proposed converter is verified through a simulation and an experiment.

부하가변시 3상 PWM 컨버터의 전류제어에 관한 연구 (Current Control of Three Phase PWM Converter for the Variable Load)

  • 이재훈;김은기;전기영;전지용;이승환;오봉환;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.441-443
    • /
    • 2007
  • In this paper, The authors design the current controller which independently control the d, q axis current transformed by the synchronously rotating d, q axis and a Space Vector Pulse Width Modulation(SVPWM) to steadily control the output DC-Link voltage against the variable load of the three phase PWM converter. Also, This study improves the high power factor, stability, and rapid response by the phase angle control using the digital Phase Locked Loop(PLL).

  • PDF

단일 전류 센서를 이용한 2상 하프브릿지 인버터의 상전류 측정 방법 (A Novel Current Measurement Method for Two-Phase Half-bridge Inverter using Single Current Sensor)

  • 조영훈;목형수;장도현;김상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.193-195
    • /
    • 2007
  • This paper proposed a novel current measurement method for two-phase half-bridge inverter using single current sensor. The proposed method measures DC link input current and a phase current simultaneously and reconstructs each phase currents by simple calculation according to voltage vector. The commutation modes of two-phase half-bridge inverter is analized. The current sampling and reconstructing method is also presented. The proposed method is verified through simulation and experimental results on two-phase induction motor drive system.

  • PDF

3-레벨 AFE 정류기의 캐리어 기반 중성점 제어 기법 (A carrier based neutral point balancing strategy for 3-level active-front-end rectifiers)

  • 강경필;김호성;조진태;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.212-213
    • /
    • 2017
  • In this paper is presented a pre-charging sequence for single-phase cascaded neutal-point-clamped(NPC) converters for capacitors voltage balancing. capacitor imbalance problem in pre-charge sequence is caused in cascaded NPC converter by its topology. the DC link voltage at each NPC converter module can be balanced by the proposed switching method. the design and performance of the proposed sequence are verified by simulation and experimental results using prototype.

  • PDF

전기자동차 충전기용 2 stage IPT 시스템 설계 (Design of Two Stage Inductive Power Transfer System for Electric Vehicle Chargers)

  • 안상준;김민중;김민국;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.112-113
    • /
    • 2017
  • 본 논문에서는 전기자동차용 배터리 충전기의 특징과 설계조건을 반영한 2 stage 자기유도방식 무선전력전송 (inductive power transfer, IPT) 시스템의 설계 방법을 제안한다. 시스템 설계 시 고려사항은 송신측 DC link 전압 범위와 수신측 듀티가변 범위, 배터리 전압 범위 등이 있다. 이와 같은 고려사항을 반영하여 2 stage IPT 시스템의 입 출력전압 범위를 선정하고 전압 전류 스트레스 분석을 통해 공진네트워크를 설계한다.

  • PDF

소용량 직류단 커패시터를 갖는 인버터로 구동되는 매입형 영구자석 동기기의 속응성 향상 기법 (Fast Dynamic Control for Interior Permanent Magnet Synchronous Motor of Small DC-Link Capacitor Based Inverter with P-Q Control)

  • 손호표;박영수;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.190-191
    • /
    • 2017
  • 본 논문에서는 소용량 직류단 커패시터를 갖는 인버터로 구동되는 매입형 영구자석 동기기의 속응성 향상을 위한 제어 기법을 제안한다. 제안하는 기법은 매입형 영구자석 동기기에서 요구되는 지령 전력을 통해 인버터 동작을 위한 지령 전압을 결정한다. 제안하는 제어 기법을 통해 매입형 영구자석 동기기의 속응성을 향상시킬 수 있다. 시뮬레이션을 통해 제안하는 기법의 타당성을 검증한다.

  • PDF