• 제목/요약/키워드: DC-link

검색결과 1,020건 처리시간 0.023초

입력 피드포워드와 퍼지 PI제어기를 갖는 3상 ZSI의 과도상태 개선 (Transient State Improvement of Three-Phase ZSI with the Input Feedforward and Fuzzy PI Controller)

  • 오연준;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.359-360
    • /
    • 2012
  • This paper proposes a scheme of auto-tuning fuzzy PI controller and input voltage feed forward to control the output voltage of a three-phase Z-source inverter (ZSI). The proposed scheme adjusts the ts (Kp and Ki) in real time in order to find the most suitable Kp and Ki for PI controller and to simplify the controller design. The proposed scheme is verified the validity by experiment and co-simulation in PSIM and MATLAB/SIMULINK both load step change and input DC voltage variation in Z-source inverter, and has compared with the conventional PID control scheme. The experiment results involve of three-phase output voltage, Z-network capacitor voltage and dc-link peak voltage value. By those analysis and comparison, the availability of the proposed method in output voltage transient response quality improving has been verified. Compared with conventional PID method, the proposed method showed a more effective and robust control performance for coping with the severe disturbance conditions.

  • PDF

Three-phase Three-level Boost-type Front-end PFC Rectifier for Improving Power Quality at Input AC Mains of Telecom Loads

  • Saravana, Prakash P.;Kalpana, R.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1819-1829
    • /
    • 2018
  • A three-phase, three-switch, and three-level boost-type PWM rectifier (Vienna rectifier) is proposed as an active front-end power factor correction (PFC) rectifier for telecom loads. The proposed active front-end PFC rectifier system is modeled by the switching cycle average model. The relation between duty ratios and DC link capacitor voltages is derived in terms of the system input currents. Furthermore, the feasible switching states are identified and applied to the proposed system to reduce the switching stress and DC ripples. A detailed equivalent circuit analysis of the proposed front-end PFC rectifier is conducted, and its performance is verified through simulations in MATLAB. Simulation results are verified using an experimental setup of an active front-end PFC rectifier that was developed in the laboratory. Simulation and experimental results demonstrate the improved power quality parameters that are in accordance with the IEEE and IEC standards.

Analysis and Control of NPC-3L Inverter Fed Dual Three-Phase PMSM Drives Considering their Asymmetric Factors

  • Chen, Jian;Wang, Zheng;Wang, Yibo;Cheng, Ming
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1500-1511
    • /
    • 2017
  • The purpose of this paper is to study a high-performance control scheme for neutral-point-clamping three-level (NPC-3L) inverter fed dual three-phase permanent magnet synchronous motor (PMSM) drives by considering some asymmetric factors such as the non-identical parameters in phase windings. To implement this, the system model is analyzed for dual three-phase PMSM drives with asymmetric factors based on the vector space decomposition (VSD) principle. Based on the equivalent circuits, PI controllers with feedforward compensation are used in the d-q subspace for regulating torque, where the cut-off frequency of the PI controllers are set at the twice the fundamental frequency for compensating both the additional DC component and the second order component caused by asymmetry. Meanwhile, proportional resonant (PR) controllers are proposed in the x-y subspace for suppressing the possible unbalanced currents in the phase windings. A dual three-phase space vector modulation (DT-SVM) is designed for the drive, and the balancing factor is designed based on the numerical fitting surface for balancing the DC link capacitor voltages. Experimental results are given to demonstrate the validity of the theoretical analysis and the proposed control scheme.

증설이 용이한 ESS기반 하이브리드 발전시스템 연구 (A Study on ESS-based hybrid power generation system with easy expansion)

  • 김희철
    • 융합정보논문지
    • /
    • 제9권1호
    • /
    • pp.68-73
    • /
    • 2019
  • 본 연구는 스마트분전반 MG(;Micro-Grid) 구성의 중심축으로 모듈형 하이브리드 발전원과 DC버스를 통하여 링크를 갖으며 표준소켓을 사용하여 불법연결을 감지 차단하는 기능을 부여하고, 전력계통의 안정화를 달성함을 목적으로 한다. 전력변환장치, 스마트분전반, 통합제어시스템의 개발과 효율적인 수요관리가 필요하며, MG 전체시스템과의 호환성이 절실하다. 이는 공통 전력 연결 규약으로 안전하고 누구나 연결을 쉽게 할 수 있는 하이브리드발전시스템으로 데이터 관리가 용이해지고 다양한 제조사의 시스템 확대설치에 대한 대비가 가능하다.

New Backstepping-DSOGI hybrid control applied to a Smart-Grid Photovoltaic System

  • Nebili, Salim;Benabdallah, Ibrahim;Adnene, Cherif
    • International Journal of Computer Science & Network Security
    • /
    • 제22권4호
    • /
    • pp.1-12
    • /
    • 2022
  • In order to overcome the power fluctuation issues in photovoltaic (PV) smart grid-connected systems and the inverter nonlinearity model problem, an adaptive backstepping command-filter and a double second order generalized Integrators (DSOGI) controller are designed in order to tune the AC current and the DC-link voltage from the DC side. Firstly, we propose to present the filter mathematical model throughout the PV system, at that juncture the backstepping control law is applied in order to control it, Moreover the command filter is bounded to the controller aiming to exclude the backstepping controller differential increase. Additionally, The adaptive law uses Lyapunov stability criterion. Its task is to estimate the uncertain parameters in the smart grid-connected inverter. A DSOGI is added to stabilize the grid currents and eliminate undesirable harmonics meanwhile feeding maximum power generated from PV to the point of common coupling (PCC). Then, guaranteeing a dynamic effective response even under very unbalanced loads and/or intermittent climate changes. Finally, the simulation results will be established using MATLAB/SIMULINK proving that the presented approach can control surely the smart grid-connected system.

Multi-Scale Dilation Convolution Feature Fusion (MsDC-FF) Technique for CNN-Based Black Ice Detection

  • Sun-Kyoung KANG
    • 한국인공지능학회지
    • /
    • 제11권3호
    • /
    • pp.17-22
    • /
    • 2023
  • In this paper, we propose a black ice detection system using Convolutional Neural Networks (CNNs). Black ice poses a serious threat to road safety, particularly during winter conditions. To overcome this problem, we introduce a CNN-based architecture for real-time black ice detection with an encoder-decoder network, specifically designed for real-time black ice detection using thermal images. To train the network, we establish a specialized experimental platform to capture thermal images of various black ice formations on diverse road surfaces, including cement and asphalt. This enables us to curate a comprehensive dataset of thermal road black ice images for a training and evaluation purpose. Additionally, in order to enhance the accuracy of black ice detection, we propose a multi-scale dilation convolution feature fusion (MsDC-FF) technique. This proposed technique dynamically adjusts the dilation ratios based on the input image's resolution, improving the network's ability to capture fine-grained details. Experimental results demonstrate the superior performance of our proposed network model compared to conventional image segmentation models. Our model achieved an mIoU of 95.93%, while LinkNet achieved an mIoU of 95.39%. Therefore, it is concluded that the proposed model in this paper could offer a promising solution for real-time black ice detection, thereby enhancing road safety during winter conditions.

고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수 (Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter)

  • 김광태
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.35-43
    • /
    • 2005
  • 종래의 컨버터-인버터 전력변환 시스템에서 do-link를 제거하여 보다 효과적인 인버터를 만들기 위하여 매트릭스 컨버터에 관하여 연구를 하고자 한다. 따라서 매트릭스 컨버터는 에너지를 저장하는 능동소자를 갖지 않는 장점이 있으나 전원이 스위치를 통하여 직접 부하에 연결되므로 전원의 리플과 노이즈가 그대로 부하에 전달되는 결점을 갖는다. 매트릭스 컨버터는 전원을 부하에 대하여 정현적으로 스위칭해야 되며, 한편 이러한 노이즈를 제거 및 보상하는 특성과 함께 역율문제도 함께 해결해야 한다. 본 연구에서는 종래의 제시된 방법에 비하여 제어어시간을 단축시킨 제어함수를 제시한다. 제시된 제어함수는 전원에 포함된 리플과 노이즈를 스위칭하는 과정에서 자동으로 보상하며 역율 1이되게 스위칭한다. 시뮬레이션 결과와 실험결과를 함께 제시한다.

3레벨 인버터의 실시간 제어를 위한 근사화 SHE PWM (Approximate SHE PWM for Real-Time Control of 2-Level Inverter)

  • 박영진;홍순찬
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.365-374
    • /
    • 1998
  • 본 연구에선는 고조파 저감효과가 크고 실시간 제어가 가능하도록 근사화된 3레벨 SHE PWM 방식을 제안하였다. SHE PWM 방식으로 특정 고조파를 제거할 수 있는 스위칭 각을 얻으면 기본파 전압의 크기에 따라 불연속적이고 비선형적인 분포를 이루게 되어 실시간제어에의 적용이 어려우므로 이들 비선형적인 분포를 부분적으로 근사화시킨 직선방식을 얻고 직선방정식의 계수들의 집합을 하나의 조견표로 작성하여 새로운 SHE PWM 스위칭 각 분포를 얻었다. 이때 인버터 dc 링크 전압의 변동을 보상할 수 있도록 인버터 출력 기본파전압과 직류전원 전압의 비를 일정하게 유지시켜며, 이렇게 새로이 얻어진 SHE PWM에 의한 스위칭 패턴을 3레벨 인버터에 적용하여 유도전동기를 운전할 때 인버터 출력전압의 고조파분포를 해석하였다. 또한 시뮬레이션을 통한 전동기 전류의 고조파 왜곡 및 토크리플 특성도 해석하여 제안한 3레벨 근사화 SHE PWM 방식의 고조파 저감효과가 3레벨 SPWM 방식의 결과와 비교하여 우수하며, 직류링크전압 변동에 대한 보상이 이루어짐을 확인하였다.

  • PDF

이중 가교제 또는 알긴산에 의해 물리적인 안정성이 향상된 히알루론산 마이크로입자의 제조 (Preparation of Hyaluronic Acid Microspheres with Enhanced Physical Stability by Double Cross-link or Alginate)

  • 김동환;송충길;;박충근;최애진;정석재;심창구;김대덕
    • 약학회지
    • /
    • 제55권1호
    • /
    • pp.69-74
    • /
    • 2011
  • Hyaluronic acid (HA) is a natural polymer consisting of disaccharide units of D-glucuronic acid and N-acetyl-D-glucosamine. It has a great potential and success in cosmetic and biomedical applications. However, native HA is highly soluble and easily metabolized by enzymes such as hyaluronidase. Thus, various studies have been reported on modifying the physicochemical properties of HA, while maintaining its biocompatibility. For controlled drug delivery, many trials for fabricating HA microspheres were achieved under chemical reaction. The HA microspheres fabricated to improve the physical stability of HA using adipic acid dihydrazide (ADH) by cross-linking reaction has been reported earlier, however it lacks the desired physical stability and rapidly decomposes by swelling or enzymes. Therefore, we prepared double cross-linked HA microspheres (DC-HA microspheres) and alginate containing HA microspheres (AC-HA microspheres) to enhance its physicochemical properties. DC-HA microspheres were prepared using trisodium trimetaphosphate (STMP) under crosslinking reaction after ADH cross-linking reaction. AC-HA microspheres were prepared by adding alginate as a networking polymer. These microspheres were characterized by morphology, particle size, zeta potential, stability against hyaluronidase. Results showed that the DC-HA and AC-HA microspheres are more stable than that of HA microspheres.

고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor)

  • 김종해;원재선
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.