• 제목/요약/키워드: DC source failure

검색결과 17건 처리시간 0.022초

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.

Power MOSFET에서 Source voltage 저하에 관한 Failure analysis (Failure analysis about deterioration of Source voltage in Power MOSFET)

  • 정재성;김종문;이재혁;하종신;박상득
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1109-1112
    • /
    • 2003
  • 본 연구는 switching mode 의 Power NMOSFET failure mode 에 관하여 분석하고 원인을 규명하였다. 분석된 power NMOSFET은 30V급이며, vender A의 상용화 제품이다. 발생한 failure mode는 power switch 회로에서 특정 ID 를 detect 하지 못하는 mode 였다. 측정결과 source voltage 가 저하되었으며, power NMOSFET DC 동작특성 분석 결과 Vgs 변화에 따라 Id 가 저하되었다. Fail 된 power MOSFET 특성값 reference는 동일 LOT의 양품을 선정하였다. De-cap후 Inversion 과 Accumulation mode 별로 Photoemission spectrum analyzer(PSA) 분석 방법을 적용하였다. 결과 accumulation mode 에서 intensity가 감소하였으며, forward diode mode에서 국소적으로 변화하는 영역이 검출되었다. SEM 분석결과 gate metal 과 source metal 의 micro-contact 이 이루어져 있었다. 이 경우 gate metal 과 source metal 사이 close loop 를 형성하여 gate charge량을 변화시켜 power NMOSFET의 출력을 저하하는 failure mode가 발생됨을 분석할 수 있었다.

  • PDF

위성 배터리 충전을 위한 태양전력조절기의 제어기 고장 분석 (Failure Analysis of Solar Array Regulator Controller for Charging Satellite Battery)

  • 양정환;박정언;윤석택
    • 한국위성정보통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.67-71
    • /
    • 2017
  • 저궤도 인공위성은 전기 에너지 원으로 주로 태양전지 배열기를 사용한다. 태양전지 배열기는 인공위성이 식구간에 들어가면 전기 에너지를 발생시키지 못하므로, 식구간에서는 배터리가 인공위성에 전기 에너지를 공급한다. 또한 태양전지 배열기는 동작 전압에 따라 출력하는 전력이 변하며, 최대 전력을 출력하는 최대전력점이 존재한다. 일광구간에서 태양전지 배열기가 최대전력을 출력하여 위성에 전기 에너지를 공급하고 남은 에너지로 배터리를 충전할 수 있도록 태양전력 조절기기가 필요하다. 태양전력 조절기의 입력에는 태양전지 배열기가 연결되고, 출력에는 배터리가 연결된다. 태양전력 조절기는 안정적인 동작을 위해 2 of 3 Hot Redundant로 동작한다. 즉, 3개의 DC-DC 컨버터가 하나의 태양전력 조절기를 구성하며, 이 DC-DC 컨버터 하나가 고장이 발생하더라도 태양전력 조절기는 안정적으로 동작한다. 본 논문에서는 태양전력 조절기 동작 중 DC-DC 컨버터의 제어기에 고장이 발생한 순간 태양전력 조절기가 어떻게 동작하는지 분석하고, 배터리와 태양전지 배열기에 어떠한 영향을 미치는가에 대하 분석한다.

Investigation of a Hybrid HVDC System with DC Fault Ride-Through and Commutation Failure Mitigation Capability

  • Guo, Chunyi;Zhao, Chengyong;Peng, Maolan;Liu, Wei
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1367-1379
    • /
    • 2015
  • A hybrid HVDC system that is composed of line commutated converter (LCC) at the rectifier side and voltage source converter (VSC) in series with LCC at the inverter side is studied in this paper. The start-up strategy, DC fault ride-through capability, and fault recovery strategy for the hybrid HVDC system are proposed. The steady state and dynamic performances under start-up, AC fault, and DC fault scenarios are analyzed based on a bipolar hybrid HVDC system. Furthermore, the immunity of the LCC inverter in hybrid HVDC to commutation failure is investigated. The simulation results in PSCAD/EMTDC show that the hybrid HVDC system exhibits favorable steady state and dynamic performances, in particular, low susceptibility to commutation failure, excellent DC fault ride-through, and fast fault recovery capability. Results also indicate that the hybrid HVDC system can be a good alternative for large-capacity power transmission over a long distance byoverhead line.

고전압 소스를 위한 모듈식 병렬운전 알고리즘 (Module Type Parallel Driving Algorithm for High Voltage Direct-Current source)

  • 우병국;이용화;강찬호;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2008
  • For high voltage DC-DC converters, the parallel operation of several high voltage source modules is necessary to reduce the material cost. In the conventional parallel operation with HDC module control unit, it is difficult to repair the HDC system for the failure of control unit. To overcome these problems, new parallel operating algorithm for high voltage DC-DC converter is presented. The proposed algorithm has no main control unit and each module can be selected as the master according to the operating conditions. Therefore, one of modules can be replaced as the master immediately when the previous master module is failed. In addition, the extension of extra modules can be simple.

  • PDF

전압형 인버터를 이용한 전압조정에 관한 연구 (A study of Voltage Regulation Using Voltage Fed Inverter)

  • 정연택;이사영;이훈구;이덕희;김길동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.393-396
    • /
    • 1990
  • This paper represented constant voltage power source equipment using voltage fed inverter. This system drived syncronizing power source, charged battery connected to DC side, and constantly maintained regardless of power source voltage variation and load variation. Output made good wave with PWM method and we proved stabile constant voltage output when AC power source is failure.

  • PDF

소자 시뮬레이션을 이용한 ESD 보호용 NMOS 트랜지스터의 항복특성 분석 (Analysis on the breakdown characteristics of ESD-protection NMOS transistors based on device simulations)

  • 최진영;임주섭
    • 전자공학회논문지D
    • /
    • 제34D권11호
    • /
    • pp.37-47
    • /
    • 1997
  • Utilizing 2-dimensional device simulations incorporating lattic eheating models, we analyzed in detail the DC breakdown characterisics of NMOS trasistors with different structures, which are commonly used as ESD protection transistors. The mechanism leading to device failure resulting from electrostatic discharge was explained by analyzing the 1st and 2nd breakdown characteristics of LDD devices. Also a criteria for more robust designs of NMOS transistor structures against ESD was suggested by examining the characteristics changes with changes in structural parameters such as the LDD doping concentration, the drain junction depth, the distance between source/drain contacts, and the source junction area.

  • PDF

DC chopper용 전류회로 개선에 관한 연구 (A study on the improvement of communiation circuit for DC chopper)

  • 노창주;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.57-68
    • /
    • 1989
  • This paper treats the analytical and experimental studies on the improvement of commutating circuit for the speed control of DC motor. A simple circuit composed of R, L and C elements is proposed here for switching off power SCR carrying the load current. The real important in this chopper circuit is to determine the reasonable values of commutating circuit constants. In this paper, the reasonable values of the commutating circuit constants are basically determined on a view point of commutating performances in the given circuit model and must satisfy the following conditions. The first, the peak commutating current should be larger than the anticipated maximum load current. The second, the circuit turn-off time (tc) must be longer than the SCR turn-off time (tq). The third, the resistor should be enough large to permit the current to be neglected in the analysis of the commutation circuit, as well as be enough small to permit to charge the capacity voltage (Ec) to the half the value of source voltage (E) before the next communication cycle is initiated. The last, the period of chopping signal must be the least possible multiple of the damping vibration period of commutating circuit. The improved chopper circuit used in the experiment under unloaded condition was composed to meet the reasonable conditions mentioned above, and a successful commuting performance was achieved without failure. Several types of microprocessor having a different value of CPU speed individually have been applied to the experiment under the loaded conditions. Also it shows that the faster the speed of CPU is, the more stable the commutation turns out.

  • PDF

Research into The Future Development of the Hybrid System for Buoy

  • Lee, Ji-Young;Kim, Jong-Do;Lee, Jong-Ho;Lee, Jin-Yeol;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.583-591
    • /
    • 2007
  • This paper reports the performance of a 150W PV-wave hybrid system with battery storage in buoy. This system was originally designed to meet a new hybrid ower system for buoy in Korea. In the case or lighted buoys and lighthouses, a light failure alarm system of wireless radio is attached so that light failures are immediately notified to the office. At lighthouse offshore fixed lights and light buoys where commercial electricity is not available, the power source depends on solar system and batteries. This power system has a various problems. Therefore energy derived from the sunshine, wind and waves has been used as the energy source lot aids to navigation. Recently a hybrid system of combining the solar, wind and the wave generator is a favorable system lot the ocean facilities like lighthouse and buoy. The hybrid system in this paper is intended for variable DC load like light, communication system in the buoy and includes a PV-wane generation system and battery. This is composed a high efficiency charging algorithm, switching converter and controller. This paper includes discussion on system reliability, power quality, and effects of hybrid system in the buoy. Simulation and experimental results show excellent performance.

Severe Accident Analysis for Wolsung Nuclear Power Plants

  • Kwon, Jong-Jooh;Kim, Myung-Ki;Park, Byoung-Chul;Kim, Inn-Seock;Hong, Sung-Yull
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.464-470
    • /
    • 1997
  • Severe accident analysis has been performed for the Wolsung nuclear power plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks(LOAH) which is caused by loss of off-site power, diesel generators, and DC power. ISAAC (Integrated Severe Accident Analysis Code)computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanism of calandria vessel and containment. In addition, some insights for accident management program(AMP) are also given.

  • PDF