• 제목/요약/키워드: DC link inverter

검색결과 449건 처리시간 0.025초

DC전압 충전 및 전원 역률 보상이 가능한 APF에 관한 연구 (A study on Active Power Filter Available for DC-Link Boost and Power Factor Control)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.53-60
    • /
    • 2013
  • In this paper, a control algorithm for active power filter (APF), which compensates for the harmonics and power factor, boosting the DC-link voltage is proposed. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter. A simple algorithm to detect the load current harmonics is also proposed. The APF and charging circuit are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF system rated at 3kVA.

DC-링크 전압균형과 최소 온-오프 시간을 고려한 새로운 3-레벨 GTO 인버터 제어기법 (A New Switching Method for 3-level GTO Inverter Considering DC-link Voltage Balancing and Minimum on/off time)

  • 이요한;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.373-375
    • /
    • 1994
  • In realizing a three-level GTO inverter, we should keep the voltage balancing of DC-link capacitors and consider minimum on/off time of GTO thyristors in order to make the same blocking voltage across each device and to minimize the harmonic components of the output voltage and current. In this raper, a new PWM scheme based on space voltage vectors, by which it is possible to keep neutral-point voltage and avoid narrow pulse, is presented. Experimental results verify that the proposed PWM control scheme is suitable fur hish power and high voltage three-level GTO inverters applied to induction motor drives.

  • PDF

A Novel Soft-Switching PWM DC/DC Converter with DC Rail Series Switch-Parallel Capacitor Edge Resonant Snubber Assisted by High-Frequency Transformer Parasitic Components

  • ;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.377-382
    • /
    • 2005
  • This paper presents two new circuit topologies of DC bus lineside active edge resonant snubber assisted soft-switching PWM full-bridge DC-DC converter acceptable for either utility AC 200V-rms or AC 400V-rms input voltage source. One topology of proposed DC-DC converters is composed of a typical voltage source-fed full-bridge high frequency PWM inverter using DC busline side series power semiconductor switching devices with the aid of a parallel capacitive lossless snubber. All the active power switches in the full-bridge arms and DC busline can achieve ZCS turn-on and ZVS turn-off commutations and the total turn-off switching power losses of all active switches can be reduced for high-frequency switching action. It is proved that the more the switching frequency of full-bridge soft switching inverter increases, the more soft-switching PWM DC-DC converter with a hish frequency transformer link has remarkable advantages for its efficiency and power density as compared with the conventional hard-switching PWM inverter type DC-DC converter

  • PDF

직류 커패시터 노후화에 따른 PV 인버터 동작 (PV Inverter Operation according to DC Capacitor Aging)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권2호
    • /
    • pp.149-155
    • /
    • 2023
  • 태양광 발전은 신재생에너지 중 가장 친숙한 발전시설로 약 10여 년 전부터 보급이 확대되기 시작해 현재 시점에서는 시스템의 유지보수관리에 대한 해결 및 기술에 관한 관심이 높아지고 있다. 특히 태양광 발전시스템의 이상 유무 및 부품 교체시기 그리고 시스템의 종합효율을 최대화할 수 있는 대책이 필요하다. 태양광발전시스템의 한 요소인 PV 인버터는 전력용 스위칭 소자에 의존하는 전력변환 시스템으로 DC/DC 컨버터 및 DC-AC 인버터 구성에 따른 직류(DC-Link) 커패시터가 사용된다. 이러한 직류 커패시터 역시 장시간 사용에 따른 노후 및 열화로 인해 PV 인버터의 발전량 감소와 전력손실 그리고 고조파(THD, 교류출력전류 종합왜형률) 증가로 신재생에너지 설비를 통한 계통 안전성(Safety)에 영향을 미치는 요인으로 분석할 수 있다. 따라서 본 논문에서는 태양광발전시스템에서 현재 운영 중인 직류 커패시터 용량 상태에 따른 PV 인버터 동작 특성을 고찰함과 동시에 신재생에너지 설비의 안전성 및 신뢰성을 확보할 수 있도록 연구내용을 제안하였다.

고주파링크방식을 이용한 PV용 PCS의 고찰 (High-Frequency DC Link Inverter for Grid-Connected Photovoltaic System)

  • 정영석;유권종;정명웅;최재호;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1313-1315
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency inverter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AD filter. The high frequency inverter bridge switching at 20kHz is used to generate bipolar PWM pulse, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. In this paper, the control algorithm for synchronous current feedback control method and a maximum power point tracking (MPPT) method using DSP are described. And, the simulation and experimental results are shown to verify the validity of the proposed system.

  • PDF

Performance Analysis of a Novel Reduced Switch Cascaded Multilevel Inverter

  • Nagarajan, R.;Saravanan, M.
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.48-60
    • /
    • 2014
  • Multilevel inverters have been widely used for high-voltage and high-power applications. Their performance is greatly superior to that of conventional two-level inverters due to their reduced total harmonic distortion (THD), lower switch ratings, lower electromagnetic interference, and higher dc link voltages. However, they have some disadvantages such as an increased number of components, a complex pulse width modulation control method, and a voltage-balancing problem. In this paper, a novel nine-level reduced switch cascaded multilevel inverter based on a multilevel DC link (MLDCL) inverter topology with reduced switching components is proposed to improve the multilevel inverter performance by compensating the above mentioned disadvantages. This topology requires fewer components when compared to diode clamped, flying capacitor and cascaded inverters and it requires fewer carrier signals and gate drives. Therefore, the overall cost and circuit complexity are greatly reduced. This paper presents modulation methods by a novel reference and multicarrier based PWM schemes for reduced switch cascaded multilevel inverters (RSCMLI). It also compares the performance of the proposed scheme with that of conventional cascaded multilevel inverters (CCMLI). Simulation results from MATLAB/SIMULINK are presented to verify the performance of the nine-level RSCMLI. Finally, a prototype of the nine-level RSCMLI topology is built and tested to show the performance of the inverter through experimental results.

비자성 부하 유도 가열용 Half-Bridge Inverter의 효율 향상에 대한 연구 (A High Efficient Half-Bridge Inverter for Induction-Heating Applications with Non-Magnetic Load)

  • 정진우;이병국;서범석;현동석;정윤철;박병욱;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.303-305
    • /
    • 1996
  • A strategy that can maximize the efficiency of the inverter system for the non-magnetic material is proposed. Frequency control and variable DC-Link voltage control are compared and analyzed by the experimental results. The experimental results show the variable DC-Link voltage control is superior to the frequency control with respect to improve the efficiency of the inverter system. MOSFETs and IGBTs are used as switching devices and IGBTs are considerable as better switching devices for improving the efficiency of the inverter system.

  • PDF

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

Performance Evaluations of Digitally-Controlled Auxiliary Resonant Commutation Snubber-Assisted Three Phase Voltage Source Soft Switching Inverter

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권1호
    • /
    • pp.1-9
    • /
    • 2003
  • This paper presents a performance analysis of typical Auxiliary Resonant Commutation Snubber-assisted three phase voltage source soft switching inverter which can operate under a condition of Zero Voltage Switching (ZVS) using a digital control scheme which is suitable for high power applications compared with resonant DC link snubber assisted soft switching inverter. The system performances of this inverter are illustrated and evaluated on the basis of experimental results.

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.