• Title/Summary/Keyword: DC hub

Search Result 8, Processing Time 0.021 seconds

Minimum Network Connection Cost Algorithm for Partially Survivable Networks Problem of Cellular Telecommunication Systems

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.1
    • /
    • pp.59-64
    • /
    • 2016
  • This paper suggests heuristic algorithm with O(mn) polynomial time complexity using Excel for partially survivable networks optimization problem of cellular telecommunication systems with m cells and n hubs. This problem only can be get the solution using linear programming or LINGO software package. The proposed algorithm connects the cell to hubs in ring network with minimum cost as the connection diversity of each cell. If the traffic of ring network (T) is T>2K for ring capacity (K), we adjust the maximum cost hub to MTSO that has a ascending order of (D/DC)/${\Delta}^+$ cell with each cell traffic demand (D) and ${\Delta}^+$=(MTSO cost-maximum cost hub) than we get the $T{\leq}2K$. Finally, we adjust MTSO to the removed maximum cost hub for the cell with 2K-$T{\geq}$(D/DC) and $_{max}{\Delta}^-$. While we using like this simple method, the proposed algorithm can be get the same optimal solution for experimental data as linear programing and LINGO software package.

Designed and Implement of the Discrete Time Kalman Filter for Speed Estimation of the Sensorless Hub Wheel Motor (속도센서가 없는 허브-휠 전동기의 속도추정을 위한 이산시간 칼만필터의 설계 및 구현)

  • Jeon, Yong-Ho;Yee, Gi-Seo;Cho, Whang
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.203-210
    • /
    • 2008
  • Since hub wheel BLDC Motor consisted of wheel and BLDCM (Brushless DC Motor) without gear reducer has high efficiency and low operation noise, it can be utilized to a driving wheel at some light rail systems. However, installing sensors for speedometer on a Hub-Wheel motor is not easy, so it requires a different speed control mechanism method for speed measurement. This paper introduces a speed control method based on simple mathematical model which uses discrete Kalman Filter to estimate and control the speed of the motor.

Flow Behavior and Performance Characteristics of Constant Air Volume Fan According to Different Hub Shape (허브 형상에 따른 정풍량 환기팬의 유동과 성능특성)

  • Lee, Ho-Ho;Choi, Hang-Cheol;Jung, Jae-Goo;Lee, Yoon-Pyo;Shin, Yoo-Hwan;Chung, Jin-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.57-62
    • /
    • 2012
  • The constant air volume flow fan can maintain constant flow rate to the wide range of exit pressure. Therefore, the use of this fan is increasing recently for ventilation of high building. Brushless DC motor is adopted to this fan because that has advantages of compactness and performance. But this type of motor protrude from impeller hub side to fan inlet. The Impeller inlet flow is influenced by size of this obstacle called hub. In this paper, the influence of hub shape on the fan performance characteristics are experimentally and numerically analyzed. CFX 12.0 is used to perform the fan internal flow analysis and numerical results are compared with the experiments. Depending on hub shape, internal loss is generated and the performance and efficiency are reduced. The best performance is occurred around $h/b_1$ = 0.25. The results of this study will be contribute to initial design of constant air volume flow fan development.

Reliability Modeling of Direct Current Power Feeding Systems for Green Data Center

  • Choi, Jung Yul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.704-711
    • /
    • 2013
  • Data center is an information hub and resource for information-centric society. Since data center houses hundreds to ten thousands servers, networking and communication equipment, and supporting systems energy saving is one of the hottest issues for green data center. Among several solutions for green data center this paper introduces higher voltage direct current (DC) power feeding system. Contrary to legacy alternating current (AC) power feeding system equipped with Uninterruptible Power Supply (UPS), higher voltage DC power feeding system is reported to be a more energy efficient and reliable solution for green data center thanks to less AC/DC and DC/AC conversions. Main focus of this paper is on reliability issue for reliable and continuous operation of higher voltage DC power feeding system. We present different types of configuration of the power feeding systems according to the level of reliability. We analyze the reliability of the power feeding systems based on M/M/1/N+1/N+1 queueing model. Operation of the power feeding system in case of failure is also presented.

An empirical study on the service quality of uTradeHub though Kano model and customer satisfaction coefficient (Kano 모형과 고객만족계수를 이용한 uTradeHub 서비스 품질에 관한 연구)

  • Song, Sunyok
    • International Commerce and Information Review
    • /
    • v.18 no.4
    • /
    • pp.55-78
    • /
    • 2016
  • In this study, service quality attributes of uTradeHub were classified based on the Kano model, and quality attributes that should be managed in priority to improve the service quality of uTradeHub were investigated using Timko's customer satisfaction coefficient(CSC) and average satisfaction coefficient(ASC). The results of the study are summarized as follows. First, as a result of classifying service quality attributes based on Kano model, 12 one dimensional qualities, 5 must-be qualities, 2 indifferent qualities were deducted, and many quality attributes of uTradeHub service were confirmed to be one dimensional quality to which is needed to be paid attention and paid more detailed attention to enhance service quality. Second, in the analysis result using Timko's customer satisfaction coefficient, "post processing for problems and complaints", "cost reduction", "efficiency of business processing" were ranked in the top of satisfaction coefficient, and they found to be quality attributes that customer satisfaction increases when service quality was satisfied. While, "post processing for problems and complaints", "interaction", "ability to respond promptly when problems occur" were ranked in the top of unsatisfaction coefficient, and they were analysed to be quality attributes that customer complaints increase when service quality was unsatisfied. Third, in the result of analyzing the quality attributes that should be managed in priority to improve the service quality of uTradeHub based on the average satisfaction coefficient(ASC), "post processing for problems and complaints", "cost reduction", "useful information" were ranked in the top 3, and they were classified as quality attributes that the satisfaction level increases more when they are improved than now, but the satisfaction level decreases when they are worsen.

  • PDF

Nonlinear variable structure system control for flexible link robot manipulators (유연성 로봇 매니퓰레이터에 대한 비선형 가변구조제어)

  • 김성태;임규만;함운철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.280-284
    • /
    • 1997
  • In this paper, Nonlinear VSS control based on bang-bang control concept is derived under the assumption that the control input is bounded. We try to derive control algorithm which has almost same performance as the time optimal control. We focus this control scheme on the real implementation of DC motor position controller of flexible link, i.e. we obtain the switching curves from the real data of DC motor system operating under the full maximum and minimum applied voltages. State space is separated into several regions and we set different switching surfaces in each region to reduce chattering problem. The efficiency of the proposed controller is compared with PID controller and it is shown that the controller converges fast than PID controller without chattering. The hybrid controller scheme is also proposed not only to control the position of hub but also to reduce the vibration of end tip of flexible link.

  • PDF

Design and Implementation of a Universal System Control Strategy Applicable to VSC-HVDC Systems

  • Zhao, Yue;Shi, Li-bao;Ni, Yi-xin;Xu, Zheng;Yao, Liang-zhong
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.225-233
    • /
    • 2018
  • This paper proposes a universal system control strategy for voltage source converter (VSC) based high voltage direct current (HVDC) systems. The framework of the designed control strategy consists of five layer structures considering the topology and control characteristics of the VSC-HVDC system. The control commands sent from the topmost layer can be transmitted to the next layer based on the existing communication system. When the commands are sent to each substation, the following transmission of commands between the four lower layers are realized using the internal communication system while ignoring the communication delay. This hierarchical control strategy can be easily applied to any VSC-HVDC system with any topology. Furthermore, an integrated controller for each converter is designed and implemented considering all of the possible operating states. The modular-designed integrated controller makes it quite easy to extend its operating states if necessary, and it is available for any kind of VSC. A detailed model of a VSC-HVDC system containing a DC hub is built in the PSCAD/EMTDC environment. Simulation results based on three operating conditions (the start-up process, the voltage margin control method and the master-slave control method) demonstrate the flexibility and validity of the proposed control strategy.

Software PLL Based Speed Control of High Speed Miniature BLDC (소프트웨어 PLL 기반 소형 고속 BLDC의 속도 제어)

  • Park, Tae-Hub;Seok, Seung-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.132-135
    • /
    • 2008
  • This paper presents a PLL(Phase Lock Loop) control method for speed control of high speed miniature BLDCM(Brushless DC Motor) using hall sensor. The Proposed PLL based speed control method uses a only phase shift between reference pulse signal according to speed reference and actual pulse signal from hall sensor. It doesn't use any speed calculation, and calculates a direct current reference from phase shift. The current reference is changed to reduce the phase shift between reference and actual pulse. So the actual speed can keep the reference speed. The proposed control scheme is very simple but effective speed control is possible.

  • PDF