• Title/Summary/Keyword: DC feeding system

Search Result 66, Processing Time 0.029 seconds

An analysis of the power quality problem at an electric train according to dead section (절연구간 통과시 전기철도 차량에 유입되는 전력 품질 분석)

  • Lee, Bong-Yi;Kim, Jae-Chul;Moon, Jong-Fil;Han, Seong-Ho;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.51-53
    • /
    • 2005
  • At the railway feeding system, a role of dead section is very important. Because, dead section is essential installation that AC feeding system meets DC feeding system or phase is changed between AC feeding systems. But, in dead section it is possible that an electric train meets interruption. In Korea, a study on the dead section isn't yet accomplished in depth. Accordingly. In this paper, when electric train is in dead-section power quality problem on electric train was dealt. Modeling and simulation using PSCAD/EMTDC was accomplished to analyze.

  • PDF

Study for Improvement of Tracking Accuracy of the Feeding System with Iron Core Type Linear DC Motor by Neural Network Control (신경망 제어에 의한 철심형 리니어모터의 추종성 향상 연구)

  • 송창규;김경호;정재한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.73-77
    • /
    • 2002
  • The requirements for higher productivity call for high speed of the machine tool axes. Iron core type linear DC motor is growly accepted far a viable candidate of the high speed machine tool feed unit. LDM, however, has inherent disturbance force components: cogging and force ripple. These disturbance force directly affects tracking accuracy of the carrage and must be eliminated or reduced. Reducing motor ripple, this paper adapted the feed forward compensation method and neural network control. Experiments carried 7ut on the linear motor test setup show that this control methods is usable in order to reduce the motor ripple.

  • PDF

Study for Improvement of Tracking Accuracy of the Feeding System with Iron Core Type Linear DC Motor (철심형 리니어모터 이송계의 추종성 향상에 관한 연구)

  • 송창규;황주호;박천홍;김경호;정재한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.71-73
    • /
    • 2001
  • The requirements for higher productivity call for high speed of the machine tool axes. Iron core type linear DC motor is growly accepted for a viable candidate of the high speed machine tool feed unit. LDM, however, has inherent disturbance force components: cogging and force ripple. These disturbance force directly affects the carrage tracking accuracy and must be eliminated or reduced. Reducing motor ripple, this paper adapted the feed forward compensation method. Experiments carried out on the linear motor test setup show that this compensation method is usable in order to reduce the motor ripple.

  • PDF

Application of regenerative inverter on DC feeding (직류급전계통의 회생용 인버터 실용화 적용)

  • Han, Moon-Seob;Jang, Dong-Uk;Shin, Hyo-Bum;Kim, Sung-Tae;Kim, Min-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2200-2201
    • /
    • 2011
  • DC railway systems have been adopted in the urban rail train. When EMU decelerates using electric breaking, regenerative power occurs. extra power is forcibly wasted by resisterIf DC transit system has inverter for reusing regenerative power, energy efficiency in DC transit system will be increased. in this paper present developed regenerative power inverter and its field test result.

  • PDF

A Study on the High Speed of Cutting Tool Feed System for the Noncircular Machining (비진원 가공용 공구 이송장치의 고속화 성능에 관한 연구)

  • 김성식
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.96-103
    • /
    • 1998
  • With the advance of processing technology , so as to spare fuel, piston heads used in automobile reciprocating engine have complex 3-dimension, with respect to shape such as ovality, profile, eccentricity, offset, recess. Therefore, coming out of the existing process work used master cam. the process work is performed using a CNC lathe. For a precision processing, the processing work is need to make study of high speed feed gear synchronized with the rotative speed of main spindle. And then the high speed feeding system must maintain high dynamic stiffness, high speed and high positioning accuracy . In this paper, in order to achieve high speed cutting tool feeding. The linear brushless DC motor is used for satisfying this process work. The ball bush and turicite is used as the guidance of the feed gear system. Also linear encoders, digital servo amplifiers and controller are used for controlling driving motor. This paper presents the design and simulation of the new tool feed system for noncircular machining.

  • PDF

Ground fault protective relaying schemes for DC traction power supply system (비접지 DC 급전계통에서 전류형 지락보호계전 방법)

  • 정상기;정락교;이성혁;김연수;조홍식
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.412-417
    • /
    • 2004
  • In urban rail transit systems, ground faults in the DC traction power supply system are currently detected by the potential relay, 64P. Though it detects the fault it cannot identify the faulted region and therefore the faulted region could not be isolated properly. Therefore it could cause a power loss of the trains running on the healthy regions and the safety of the passengers in the trains could be affected adversely. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. A current limiting device, called Device X, is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. One type of the relaying schemes is called directional and differential ground fault protective relay which uses the current differential scheme in detecting the fault and uses the permissive signal from neighboring substation to identify the faulted region correctly. The other is called ground over current protective relay. It is similar to the ordinary over current relay but it measures the ground current at the device X not at the power feeding line, and it compares the current variation value to the ground current in Device X to identify the correct faulted line. Though both type of the relays have pros and cons and can identify the faulted region correctly, the ground over current protective relaying scheme has more advantages than the other.

A study on dynamic simulation for estimation of leakage current (누설전류 예측을 위한 동적 시뮬레이션에 관한 연구)

  • Jung, Ho-Sung;Han, Moon-Seob;Park, Young;Chung, Sang-Gi;Kwon, Sam-Young;Lee, Jea-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.250-252
    • /
    • 2008
  • DC traction system generates leakage current because running rails are used in return circuit. And it is very important to estimate the leakage current to the train operation situation. Therefore this paper presents dynamic simulation technique that is very similar to the real operation situation using TPS and PSCAD/EMTDC. For this we model DC traction system included in DC substation, variable feeding circuit model and variable train model. And we extract train location and power using TPS program and use these data for dynamic simulation. Finally we can estimate leakage current to the various operation condition using dynamic simulation.

  • PDF

A Study on DC Power Regeneration for Railway using Parallel PWM Converter (병렬 PWM 컨버터를 이용한 철도차량 직류 전력 회생장치에 관한 연구)

  • Lee Jong-Moo;Jang Su-jin;Song Sang-Hun;Won Chung-Yuen;Ahn Kyu-Bok;Lee Joon-Gee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.524-527
    • /
    • 2004
  • When the electric tractions are stopped or driven through the falling slope way, it occured to surplus energy in the DC power line. At present, these energy are exhausted by breaking-system. The converter is not only capable of feeding energy back into the AC source during excessive regeneration. It is issued for this surplus energy regenerating system. These systems are faced with high voltage and high power for railway DC power regeneration. This paper proposed a parallel PWM converter how to solve these problem.

  • PDF

Driving Characteristic Analysis of Brushless DC Motor Considering PWM Mode (PWM 모드를 고려한 브러시리스 DC 전동기의 구동 특성 해석)

  • Shin Hyun-Hun;Lee Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.98-107
    • /
    • 2005
  • Brushless DC motor(BLDCM) can be driven by 120[^{\circ}]$ square wave voltage and use PWM pulse patterns in two-phase feeding scheme to control the speed of the motor. This Paper introduces four PWM modes used BLDCM control system, and analyzes their different influences on the motor performances using a time-stepped voltage source finite element method. To verify the proposed computational method, we built the prototype motor for electrical power steering(EPS) and compared the predicted and the measured back EMF and phase current.