• Title/Summary/Keyword: DC breakdown

Search Result 188, Processing Time 0.03 seconds

Varistor Properties and Aging Behavior of V/Mn/Co/ La/Dy Co-doped Zinc Oxide Ceramics Modified with Various Additives

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.5
    • /
    • pp.284-289
    • /
    • 2014
  • The effects of additives (Nb, Bi and Cr) on the microstructure, varistor properties, and aging behavior of V/Mn/Co/ La/Dy co-doped zinc oxide ceramics were systematically investigated. An analysis of the microstructure showed that all of the ceramics that were modified with various additives were composed of zinc oxide grain as the main phase, and secondary phases such as $Zn_3(VO_4)_2$, $ZnV_2O_4$, and $DyVO_4$. The $Bi_2O_3$-modified samples exhibited the lowest density, the $Nb_2O_5$-modified sample exhibited the largest average grain size, and the $Cr_2O_3$-modified samples exhibited the highest breakdown field. All additives improved the non-ohmic coefficient (${\alpha}$) by either a small or a large margin, and in particular an $Nb_2O_5$ additive noticeably increased the non-ohmic coefficient to be as large as 36. The $Bi_2O_3$-modified samples exhibited the highest stability with variation rates for the breakdown field and for the non-ohmic coefficient (${\alpha}$) of -1.2% and -26.3%, respectively, after application of a DC accelerated aging stress of 0.85 EB/$85^{\circ}C$/24 h.

The Influence of Combustion Flame on AC and DC Flashover Characteristics in the Air-Gaps Simulated Overhead Power Lines (가공(架空)전력선을 모의(模擬)한 공기 갭에서 교류 및 직류 섬락특성에 미치는 연소화염의 영향)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.152-159
    • /
    • 2010
  • A combustion flame under the overhead power lines may be caused by breakdown disturbances in power systems. In this study, experiments were conducted for the purpose of investigating the reduction in insulation strength caused by combustion flame and the shape changes of the flame, and flashover characteristics and extinction phenomena of the flame in the simulated conditions of overhead power lines were examined under the application of a.c. and d.c. high-voltages. As the results of the experimental investigation, it is demonstrated that flame can remarkably reduce breakdown voltages of the air-gap in shorter range of the gap distance. As the gap distance increases, flame was quenched, before the flashover, by corona wind generated from the needle electrodes.

Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor (UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

A Study on the Insulation Characteristics of Epoxy Composites Using Electric Field Simulation

  • Lee, Deok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.53-60
    • /
    • 2021
  • In this paper, we aimed to identify the insulation characteristics and reliability of Epoxy composites, which are widely used as insulation material for electrical & electronic components and electric appliance. To this end, it was necessary to predict variations of electric field due to the distribution of fillers that must be added by economic and mechanical factors. So, we verified the result using an electric field analysis Simulator. Furthermore, under the condtion of DC voltage application, an dielectirc breakdown test was performed according to ambient temperature changes and the distribution of fillers, and the changes were observed. Three types of specimens were manufactured by adding 0, 50 and 100[phr] filling to Epoxy resin. In all specimens, as temperature was increased, the strength of the dielectric strength was decreased. When comparing the simulation results with the actual dielectric breakdown test results, we was able to confirm the technical applicability required for Insulation design of electric appliance.

Comparison of DC/AC breakdown characteristics of polymer sheets for polymer insulator (실리콘 베이스와 첨가제 함량에 따른 폴리머애자용 고분자의 DC/AC 절연파괴 특성 연구)

  • Seong, Jae-Kyu;Seo, In-Jin;Park, Tae-Gun;Shin, Woo-Ju;Oh, Seok-Ho;Khan, Umer Amir.;Hwang, Jae-Sang;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1592-1593
    • /
    • 2011
  • 전 세계적으로 전력사용량의 증가와 전력기술이 발전함에 따라 절연소재 또한 급속한 발전을 가져왔다. 특히 폴리머 애자는 경량성, 내오염성, 시공의 용이성 등과 같은 장점으로 오랫동안 사용해온 자기 애자를 대체하여 사용되고 있다. 최근 고효율 장거리 전력 송전이 가능한 HVDC 송전선로가 증가함에 따라 직류 절연물에 대한 연구가 활발히 이루어지고 있다. 본 연구에서는 두 종류의 실리콘 베이스와 첨가제 함량을 변화시킨 폴리머 시편의 직류 파괴전압 실험과 교류 파괴전압 실험을 실시하였다. 취득한 데이터를 Weibull 분포를 통해 분석 한 결과 직류 파괴전압이 교류 파괴전압에 비해 2~5배 높은 것으로 나타났다.

  • PDF

Compensation Scheme for Dead Time and Inverter Nonlinearity Insensitive to IPMSM Parameter Variations (IPMSM 파라미터 변화에 영향 받지 않는 데드타임 및 인버터 비선형성 보상기법)

  • Park, Dong-Min;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.213-221
    • /
    • 2012
  • In a PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive, a dead time is inserted to prevent a breakdown of switching device caused by the short-circuit of DC link. This distorts the inverter output voltage resulting in a current distortion and torque ripple. In addition to the dead time, nonlinearity exists in switching devices of the PWM inverter, which is generally dependent on operating conditions such as the temperature, DC link voltage, and current. The voltage disturbance caused by the dead time and inverter nonlinearity directly influences on the inverter output performance, and it is known to be more severe at low speed. In this paper, a new compensation scheme for the dead time and inverter nonlinearity under the parameter variation is proposed for a PWM inverter-fed IPMSM drive. The overall system is implemented using DSP TMS320F28335 and the validity of the proposed algorithm is verified through the simulation and experiments.

DC Characteristics of P-Channel Metal-Oxide-Semiconductor Field Effect Transistors with $Si_{0.88}Ge_{0.12}(C)$ Heterostructure Channel

  • Choi, Sang-Sik;Yang, Hyun-Duk;Han, Tae-Hyun;Cho, Deok-Ho;Kim, Jea-Yeon;Shim, Kyu-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.2
    • /
    • pp.106-113
    • /
    • 2006
  • Electrical properties of $Si_{0.88}Ge_{0.12}(C)$ p-MOSFETs have been exploited in an effort to investigate $Si_{0.88}Ge_{0.12}(C)$ channel structures designed especially to suppress diffusion of dopants during epitaxial growth and subsequent fabrication processes. The incorporation of 0.1 percent of carbon in $Si_{0.88}Ge_{0.12}$ channel layer could accomodate stress due to lattice mismatch and adjust bandgap energy slightly, but resulted in deteriorated current-voltage properties in a broad range of operation conditions with depressed gain, high subthreshold current level and many weak breakdown electric field in gateoxide. $Si_{0.88}Ge_{0.12}(C)$ channel structures with boron delta-doping represented increased conductance and feasible use of modulation doped device of $Si_{0.88}Ge_{0.12}(C)$ heterostructures.

Turn-to-Turn Dielectric Characteristics of Coils for HTSFCL (고온초전도 한류기용 코일의 턴간 절연 특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Nguyen, Van Dung;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.15-18
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

  • PDF

Mixed-Mode Transient Analysis of HBM ESD Phenomena (HBM ESD 현상의 혼합모드 과도해석)

  • Choe, Jin-Yeong;Song, Gwang-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • Based on mixed-mode transient analyses utilizing a 2-dimensional device simulator, we have suggested the methodology to analyze the HBM ESD phenomena in CMOS chips utilizing NMOS transistors for ESD protection, and have analyzes the HBM discharge mechanisms in detail. Also the second breakdown characteristics in the protection device have been successfully simulated based on mixed-mode simulations, to explain the discharge mechanisms leading to device failure. To analyze the effects of the device structure changes on the discharge characteristics, we have compared the results of DC analyses and mixed-mode transient analyses, and have discussed about more robust designs of NMOS transistor structures against HBM ESD based on the analyses.

  • PDF

Design and Analysis of Electrical Properties of a Multilayer Ceramic Capacitor Module for DC-Link of Hybrid Electric Vehicles

  • Yoon, Jung-Rag;Moon, Bong Hwa;Lee, Heun Young;Jeong, Dae Yong;Rhie, Dong Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.808-812
    • /
    • 2013
  • Multilayer capacitors with high ripple current and high capacitance were manufactured. The electrical properties of these capacitors were characterized for potential application for DC-link capacitors in hybrid electric vehicle inverters. Internal electrode structures were designed to achieve high capacitance and reliability. A single multilayer capacitor showed $0.46{\mu}F/cm^3$ of capacitance, 0.65% of dielectric loss, and 1450 V to 1650 V of dielectric breakdown voltage depending on the design of the internal electrode. The capacitor module designed with several multilayer capacitors gave a total capacitance of $450{\mu}F$, which is enough for hybrid electric vehicles. In particular, an equivalent series resistance of $4.5m{\Omega}$ or less will result in 60 $A_{rms}$, thereby reaching the allowed ripple current for hybrid electric vehicles.