• Title/Summary/Keyword: DC Output Voltage control

Search Result 728, Processing Time 0.022 seconds

A Decentralized Optimal Load Current Sharing Method for Power Line Loss Minimization in MT-HVDC Systems

  • Liu, Yiqi;Song, Wenlong;Li, Ningning;Bai, Linquan;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2315-2326
    • /
    • 2016
  • This paper discusses the elimination of DC voltage deviation and the enhancement of load current sharing accuracy in multi-terminal high voltage direct current (MT-HVDC) systems. In order to minimize the power line losses in different parallel network topologies and to insure the stable operation of systems, a decentralized control method based on a modified droop control is presented in this paper. Averaging the DC output voltage and averaging the output current of two neighboring converters are employed to reduce the congestion of the communication network in a control system, and the decentralized control method is implemented. By minimizing the power loss of the cable, the optimal load current sharing proportion is derived in order to achieve rational current sharing among different converters. The validity of the proposed method using a low bandwidth communication (LBC) network for different topologies is verified. The influence of the parameters of the power cable on the control system stability is analyzed in detail. Finally, transient response simulations and experiments are performed to demonstrate the feasibility of the proposed control strategy for a MT-HVDC system.

The Control Characteristics of PV System Using Discrete Data Signal (이산치 신호를 이용한 PV시스템의 제어특성)

  • 김동휘;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.93-96
    • /
    • 1999
  • Solar cell generate DC power from sunlight whose power is different at any instance according to condition of variables : insolation and temperature. In order to improve the system utility factor and efficiency of energy conversion, it is desirable to operate the PV system at maximum power point of solar cell under different condition. In this paper, Boost chopper is controlled it output voltage with a new discrete control algorithm for MPPT. PWM signal of DC-DC converter are generated with a 89C51 microcontroller. Switching frequency of DC-DC converter is set at 10KHz. Simulation and experimental results show that the PV system studied in this paper is always operated at maximum power point under different maximum power point of solar cells having stabilized output voltage waveform with relatively small ripple component

  • PDF

On the Optimum Linear Voltage Regulator of a Self-excited DC Shunt Generator (직류자여자분권발전기의 최적선형전압조정기에 관한 연구)

  • Jong Swoo Won
    • 전기의세계
    • /
    • v.22 no.4
    • /
    • pp.11-16
    • /
    • 1973
  • This paper presents an optimum control of the field resistance for the self-excited DC shunt generator to keep a constant terminal voltage in case of the load change or the torque variation in the system. The non-linearity of the system is linearized by applying the small signal technique and the linearized equation is solved by the maximum principle with the digital computer. The optimal control value of the field resistance for the step error of the generator output voltage is obtained and the transient voltage characteristics in the system are investigated.

  • PDF

Fault Diagnosis and Fault-Tolerant Control of DC-link Voltage Sensor for Two-stage Three-Phase Grid-Connected PV Inverters

  • Kim, Gwang-Seob;Lee, Kyo-Beum;Lee, Dong-Choon;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.752-759
    • /
    • 2013
  • This paper proposes a method for fault diagnosis and fault-tolerant control of DC-link voltage sensor for two-stage three-phase grid-connected PV inverters. Generally, the front-end DC-DC boost converter tracks the maximum power point (MPP) of PV array and the rear-end DC-AC inverter is used to generate a sinusoidal output current and keep the DC-link voltage constant. In this system, a sensor is essential for power conversion. A sensor fault is detected when there is an error between the sensed and estimated values, which are obtained from a DC-link voltage sensorless algorithm. Fault-tolerant control is achieved by using the estimated values. A deadbeat current controller is used to meet the dynamic characteristic of the proposed algorithm. The proposed algorithm is validated by simulation and experiment results.

Low-area Dual mode DC-DC Buck Converter with IC Protection Circuit (IC 보호회로를 갖는 저면적 Dual mode DC-DC Buck Converter)

  • Lee, Joo-Young
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.586-592
    • /
    • 2014
  • In this paper, high efficiency power management IC(PMIC) with DT-CMOS(Dynamic threshold voltage Complementary MOSFET) switching device is presented. PMIC is controlled PWM control method in order to have high power efficiency at high current level. The DT-CMOS switch with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuit consist of a saw-tooth generator, a band-gap reference(BGR) circuit, an error amplifier, comparator circuit, compensation circuit, and control block. The saw-tooth generator is made to have 1.2MHz oscillation frequency and full range of output swing from supply voltage(3.3V) to ground. The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on current mode PWM control circuits and low on-resistance switching device, achieved the high efficiency nearly 96% at 100mA output current. And Buck converter is designed along LDO in standby mode which fewer than 1mA for high efficiency. Also, this paper proposes two protection circuit in order to ensure the reliability.

A Functional Circuits Design of Variable Frequency Switching type DC-DC Converter Integrated Circuit (가변주파수 스위칭 DC-DC 컨버터용 집적회로를 위한 기능 회로 설계)

  • Lee, Jun-sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.139-144
    • /
    • 2016
  • This paper describes functional circuits of DC-DC converter IC incorporated with variable frequency PFM technique. In case of output voltage of DC-DC converter is reached setting value or output current is low then PFM switching frequency is slow down. In this work a PFM signal generator, a PFM Frequency Control Circuit, an output voltage detector and an over current protection circuits are designed. This device has been designed at a $0.35[{\mu}m]$, double poly, double metal 12[V] CMOS process.

Analysis and Design Considerations for a High Power Buck Derived LED Driver with Extended Output Voltage and Low Total Harmonic Distortion

  • Lv, Haijun;Wu, Xinke;Zhang, Junming
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1137-1149
    • /
    • 2017
  • In order to reduce the cost, improve the efficiency and simplify the complicated control of existing isolated LED drivers, an improved boundary conduction mode (BCM) Buck ac-dc light emitting diode (LED) driver with extended output voltage and low total harmonic distortion is proposed. With a coupled inductor winding and a stacked output, its output voltage can be elevated to a much higher value when compared to that of the conventional Buck ac-dc converter, without sacrificing the input harmonics and power factor. Therefore, the proposed Buck LED driver can meet the IEC61000-3-2 (Class C) limitation and has a low THD. The operating principle of the topology and the design methodology of the ac-dc LED driver are presented. A 150 W ac-dc prototype was built in the laboratory and it shows that the input current harmonics meet the lighting standard. In addition, the THD is less than 16% at a typical ac input. The peak efficiency is higher than 96.5% at a full load and a normal input.

Characteristic of Boost input type active clamp DC-DC converter (Boost 입력형 능동클램프 DC-DC 컨버터의 동작특성)

  • Ceong, Cin-Beom;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.301-303
    • /
    • 2001
  • This paper proposes the boost input type active clamp DC-DC converter featuring the high efficiency and improved EMI characteristics. The main characteristic of the converter is to operate with the non-pulsating input and output currents. Besides, it has the zero-voltage switching (ZVS) and low voltage stress characteristics. For the proposed converter, the detailed operation principles and the simulation results are presented.

  • PDF

Parallel Control Method of a Modular DC/DC Converter for Electric Vehicle Chargers (전기차 충전기용 모듈형 DC/DC 컨버터의 병렬 제어 기법)

  • Choi, Hye-Won;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.101-108
    • /
    • 2021
  • This paper proposes a parallel control method of a modular DC/DC converter for electric vehicle (EV) chargers. The EV chargers have been increasing the power capacity using modular converters. There are output current imbalances between the modules, which are caused by the difference of the impedance, delay of the gate driver, and error of the sensors. The conventional strategies for the equal distribution of the output current cause the voltage drop or the high volume and cost of the converters. Therefore, the proposed parallel control strategy effectively balances the output current of modules using a current compensation method. The proposed strategy is verified by simulations. Additional experimental results will be added under various conditions.

A Control Technique for 120Hz DC Output Ripple-Voltage Suppression Using BIFRED with a Small-Sized Energy Storage Capacitor

  • Kim Jung-Bum;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.190-197
    • /
    • 2005
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still maintains generally good performance such as low THD of input line current and a high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and smaller size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.