• 제목/요약/키워드: DC Link Electrolytic Capacitor

검색결과 36건 처리시간 0.063초

전력변환기에 대한 직류링크 커패시터의 고장진단을 위한 간단한 용량 추정 기법 (A Simple Capacitance Estimation Method for Failure Diagnosis of DC Link Electrolytic Capacitor in Power Converters)

  • 손진근;김동준
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.378-383
    • /
    • 2010
  • Due to the large capacity and low cost, DC link electrolytic capacitors with of energy storage and voltage regulation are used for almost all types of power converter as the DC/AC inverter or DC/DC converter. Electrolytic capacitor, which is the most of the time affected by the aging effect, plays very important role for the power converter system quality and reliability. Therefore, this paper proposes a simple method to estimate the capacitance variation of an electrolytic capacitor in order to analyze the internal characteristic decrease and worn-out state of an electrolytic capacitor. Simulation results by using capacitor storage energy computation show the validity of the proposed capacitance estimation method.

PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단 (An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters)

  • 손진근;나채동
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

인버터 직류링크 전압 평활용 전해 커패시터의 고장 진단 (Fault Diagnosis of a Electrolytic Capacitor for Inverter DC-Link Voltage Smoothing)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.372-377
    • /
    • 2007
  • 본 논문은 가변속 구동 장치에서 직류링크 전압 평활용으로 사용되는 전해 커패시터의 새로운 고장 진단 방법을 제안한다. 전해 커패시터의 등가직렬저항은 직류링크 전압과 부하 전류로부터 직접 추정되고, 추정된 등가직렬저항으로부터 전해 커패시터의 상태가 결정된다. 온도 변동에 따른 등가직렬저항 변동을 보상하기 위해, 커패시터 주변의 PCB에 다이오드를 부착하고 다이오드의 전압 강하로부터 커패시터의 온도를 간접적으로 검출한다. 시뮬레이션 및 실험은 제안된 방식의 효용성을 보인다.

Control of Motor Drives Fed by PFC Circuits without DC-Link Electrolytic Capacitors

  • Kim, Kwang-Man;Kim, Eung-Ho;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1067-1074
    • /
    • 2018
  • This paper presents a control method for variable-speed motor drives that do not use a DC-link electrolytic capacitor. The proposed circuit consists of a power factor correction converter for boosting the DC-link voltage, an inverter for driving the motor, and a small DC-link film capacitor. By employing a small DC-link capacitor, the proposed circuit that is small, and a low cost and weight are achieved. However, because the DC-link voltage varies periodically, the control of the circuit is more difficult than that of the conventional method. Using the proposed control method, an inverter can be controlled reliably even when the capacitance of the DC-link capacitor is very small. Experiments are performed using a 1.5-kW inverter with a $20-{\mu}F$ DC-link capacitor, and the experimental results are analyzed thoroughly.

DSP를 적용한 전력용 DC 평활 커패시터의 이더넷 원격 고장진단시스템 개발 (A Development of Ethernet-Based Remote Diagnosis System for DC Voltage Smoothing Capacitor using DSP)

  • 손진근
    • 전기학회논문지P
    • /
    • 제60권2호
    • /
    • pp.94-98
    • /
    • 2011
  • Electrolytic power capacitors today form essential components for virtually any power electronic system such as DC/DC converter or UPS. Frequently, electrolytic capacitors for DC link voltage smoothing are the key components which determine the life cycle of the whole unit and often are responsible for converter breakdown failures. In this paper, ethernet-based remote diagnosis system for DC voltage smoothing capacitor using DSP control board is developed. To estimate the status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The ESR detection scheme is based on the determination of the capacitor ripple power losses calculated from DC link voltage/current measurement. Experimental results show the veridity and reliability of the proposed ethernet-based remote on-line capacitor diagnosis system.

Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발 (A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication)

  • 김동준;손진근;전희종
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

인버터의 직류단 전해 커패시터 고장 진단 (Fault Diagnosis of DC Link Electrolytic Capacitors in Inverter)

  • 양진규
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.145-152
    • /
    • 2013
  • Electrolytic capacitors used for smoothing DC link voltage is one of the major root causes of fault in power electronic system. The aging of aluminum electrolytic capacitors is expressed by the increase of their equivalent series resistance (ESR) and the reduction of their capacitance. Thus, the proposed technique in this paper is to measure capacitance, by comparing energy loss of DC link capacitors with stator resistor in electric machine. Condition of DC link capacitors can be estimated from the capacitance decrease rate between initial and aged capacitors. The results show that the proposed technique provides an easy, widely applicable and simple low cost solution for detecting dc link capacitor degradation.

3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구 (The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response)

  • 박현수
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.117-122
    • /
    • 2018
  • 대용량 3상 시스템 에어컨은 최근 들어 소비 전력 저감을 위해 인버터 회로를 포함하고 있다. 인버터 회로는 교류를 다이오드를 통해 정류하고 DC-link 전원부 콘덴서에 의해 평활된 직류를 사용한다. 이 때 평활에 사용되는 DC-link 전원부 콘덴서는 전압 리플, 전류 리플 조건을 만족하기 위해 전해 콘덴서가 일반적으로 사용된다. 콘덴서의 용량을 줄이게 되면 회로부의 크기 및 무게, 비용을 줄일 수 있게 된다. 본 논문에서는 최소점 추정 PPL(Phase Locked Loop) 위상 제어와 평균 전압 d축 전류제어 기법을 조합하여 입력 리플 전류를 약 90% 저감하는 알고리즘을 제안한다. 입력 리플 전류의 감소로 인해 DC-link 콘덴서의 전류 리플도 감소하므로 콘덴서의 용량을 줄일 수 있지만 전해 콘덴서의 경우 등가 직렬 저항(ESR : Equivalent Series Resistance)이 크기 때문에 발열로 인한 수명이 한계를 가진다. 본 논문에서는 전해 콘덴서 대신 DC-link 단에 전류 리플을 고려한 필름 콘덴서를 선정하는 방법을 제안한다. 필름 콘데서의 정전 용량 선정, 내압 선정, RMS(Root Mean Square) 전류 용량, RMS 전류 주파수 해석을 고려해 콘덴서의 용량을 선정할 경우 1680uF의 전해 콘덴서를 20uF로 용량을 낮추어 설계함으로써 전원부 콘덴서의 크기 및 무게, 비용을 줄였으며 전동기 구동을 통해 동작을 확인하였다.

대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선 (Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors)

  • 이태봉
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.213-218
    • /
    • 2017
  • The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully.

인버터용 전해커패시터의 수명 추정 (Life Estimation of Electrolytic Capacitors for Inverters)

  • 이동춘;김형진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권7호
    • /
    • pp.338-346
    • /
    • 2001
  • In this paper, dc link currents for the three-phase diode rectifiers and PWM inverters are analyzed and an algorithm of estimating the life of dc link electrolytic capacitors using the analyzed ripple current is presented. Since the capacitor life is dependent on the operating temperature, the power dissipation in capacitors should be calculated. For this, the ESR(equivalent series resistance) model of the capacitor is derived and ripple currents through the capacitor are analyzed. Relating the power dissipation and the heat transfer equation, the internal operating temperature is calculated. Then, the capacitor life can be predicted by using Arrhenius's equation. An example for applications is given for the practical system.

  • PDF