• 제목/요약/키워드: DC Electric Field

검색결과 286건 처리시간 0.036초

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구 (Study on the effect of DC voltage in oil-immersed transformer insulation system)

  • 장효재;김용한;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

직류전기장에 의한 기포의 변형과 이탈에 관한 연구 (A Study on the Bubble Deformation and Departure Under DC Electric Field)

  • 권영철;김무환;강인석;김석준
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.

HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가 (DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination)

  • 권익수;황재상;구재홍;사카모토 쿠니아키;이방욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.39-46
    • /
    • 2015
  • 기중종단 접속함은 지중케이블과 가공송전선을 연결하기 위한 접속함으로써 옥외 변전소 등의 대기 중에 설치된다. 이는 21세기 핵심기술로 여겨지고 있는 대륙 간, 국가 간, 육지-섬을 잇는 HVDC 송전선로의 DC 그리드 송전망 형성을 위해 반드시 개발되어야 하는 전력기기이다. 그러나 AC용 접속함의 개발 사례는 다수 존재하는 반면, DC용 접속함의 개발 사례 및 기술은 일본과 중국 등에 일부 존재할 뿐 국내 기술은 부족한 실정이다. 따라서 본 논문에서는 기존 AC용 슬립 온형 기중 종단접속함을 초기모델로 선정하여 HVDC 전력기기로의 적용 가능성을 평가하였다. 먼저 실제 운전 시 기중종단 접속함 내 도체에서 발생하는 열에 의한 내 외부의 온도편차를 고려한 DC 전계해석을 수행하였으며, AC 전계분포 및 열 해석이 반영되지 않은 DC 전계분포와 비교하였다. 또한 DC 전계는 정상상태 뿐만 아니라 과도 구간도 포함하기 때문에 이를 고려한 전계해석을 수행할 필요가 있기 때문에 정상상태와 더불어 극성반전 후 전계분포 역시 비교, 분석하였다. 마지막으로, 기존 AC용 슬립 온형 기중 종단접속함 초기모델을 DC에 적용하기 위해 다양한 형상 변환을 통한 요소 설계를 수행하였다. 기중종단 접속함 구조 내 전계가 가장 집중될 것으로 사료되는 부분을 선정하여 그 지점들의 최대 전계강도 $E_{n.max}$$E_{t.max}$를 측정하였다. 해석 결과, 정상상태시 개선모델의 삼중점 최대 전계강도는 기준모델 대비 2.01% 개선되었으며, 연면 최대 전계강도는 기준모델 대비 36.68% 개선되었다. AC 전계해석 결과인 연면 전계강도 1.11 kV/mm보다는 33.3% 감소하였지만 삼중점 최대 전계강도 8.23 kV/mm보다는 아직 43.6% 크다는 점에서 부분적인 형상 변환이 아닌 DC 환경에 적합한 전혀 다른 근본적인 설계 개념의 변화가 반드시 필요할 것으로 사료된다.

MAGNETIC PROPERTIES OF FERRITE CORES UNDER DC-BIASED FIELD

  • Fukunaga, H.;Masumoto, S.;Ohta, Y.;Kakehashi, H.;Ogasawara, H.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.606-609
    • /
    • 1995
  • Ferrite cores are often magnetized under DC-biased field because they have been intensively used in electronic circuits such as an inverter circuit and a switching regulator circuit. Thus we investigated the effects of DC-biased field on magnetic properties in the frequency range of DC-100kHz for two kinds of ferrite cores, TDK PC38 and TDK $H_{3}S$, which have different shapes of B-H loop from each other. The magnetic loss per cycle, W/f, in the $H_{3}S$ core decreased with increasing the strength of DC-biased field, although W/f in the PC38 core increased monotonically with DC-biased field. The observed decreasing tendency differs from the previous result for Si-Fe and ferrite cores, and can be attributed to decrease in eddy current loss as well as that in hysteresis loss.

  • PDF

A New Field Sequential Stereoscopic LCDs by use of Dual-Directional-Backlight

  • Yuuki, A.;Agari, M.;Iwsaki, N.;Sasagawa, T.;Tahata, S.;Satake, T.;Murakami, O.;Oda, K.;Ito, A.;Miyake, S.
    • Journal of Information Display
    • /
    • 제5권2호
    • /
    • pp.6-9
    • /
    • 2004
  • We have developed the Scan-backlight Stereoscopic LCD that is a kind of field-sequential -Stereoscopic LCD combining the Dual- Directional- Backlight and the fast-response OCB panel. The Dual-Directional-Backlight using a double-sided prism sheet can change the direction of light by switching the LED light sources. The OCB panel using Feed-Forward Drive can realize frame rate of 120 Hz. As a result, the Scan-backlight Stereoscopic display works at its original resolving power, and produces flicker-free stereoscopic images. This auto- stereoscopic display can resolved the problems of the double images and the pseudoscopic images in case of watching at oblique angles.

전철 탑재용 DC 피뢰기의 설계 및 전계분포 특성 (Electric Field Analysis and Design of Direct current Arresters for electric Traction Vehicles)

  • 조한구;유대훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1442_1442
    • /
    • 2009
  • This paper describes electric field analysis and design of direct current arresters for electric traction vehicles. Generally, DC arresters are used to protect the electric traction to limit the overvoltage invading into its inner electrical circuits. We could proposed operating voltage(Uc), the rated voltage(Ur). Finally maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the DC arresters.

  • PDF

균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성 (Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields)

  • 김태기;김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

전기장 인가에 따른 프로판 예혼합 화염의 희박연소 특성 (Lean Burn Combustion Characteristics of Propane Premixed Flame in Electric Field)

  • 김민석;최준영;김태훈;김혜민
    • 한국분무공학회지
    • /
    • 제28권1호
    • /
    • pp.24-31
    • /
    • 2023
  • In this study, characteristics of a propane-air premixed flame sin DC electric field was investigated. The stainless steel Bunsen burner and the stainless steel ring were used as electrode, and the high voltage supply was used for applying electric field. Flammability range increased significantly when the positive voltage was applied because of extension of LBO limit, while it shrank when the negative voltage was applied. The reason for this was not much related to the burning velocity, but the induced flow around the burner by electric field. withNOx production slightly increased after positive voltage was applied in identical equivalence ratio. Nevertheless, it was advantageous to apply the positive electric field to reduce the NOx since the extension of LBO limit makes the burner possible to operate in very low equivalence ratio.

대향류 확산화염의 소염특성에 미치는 직류전기장의 영향에 관한 실험적 연구 (Experimental Study on the Effect of DC Electric Field on Extinction Characteristics of Counterflow Diffusion Flame)

  • 박익형;김민국;원상희;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.253-259
    • /
    • 2006
  • The effect of DC electric fields on the flame extinction was investigated experimentally in counterflow configurations for the methane/oxygen/nitrogen diffusion flame. The electric fields was applied by connecting the high voltage and ground terminals to the upper and lower burners, respectively. In case of having electric fields, several modes of flame extinction was observed according to the electric field intensity and strain rate defined by the exit velocity. To visualize and characterize the flame structure and intensity, planar LIF technique was adopted for OH radicals. Consequently, several length scales, including the flame width, thickness, and height from the burner tip, were introduced to explain the various flame behaviors and to characterize the flame extinctions. It was found that the variation of flame width and the chemical reaction are strongly related to a critical electric field intensity, thus the various modes of diffusion flame extinction could be observed due to the electric fields.

  • PDF